Honeywell FC-SDO-0824
-
Product Name: Honeywell Safety Manager Series Fail-Safe Digital Output (SDO) Module, Model FC-SDO-0824
-
Product Introduction: This is a certified safety-rated digital output module designed for Honeywell Safety Manager (Experion PKS SCS / FSC) systems. It executes safety logic decisions by switching 24 VDC field loads such as solenoids, alarms, and pilot valves. On loss of communication or internal fault, outputs revert to a predefined safe state (de-energized).
JRCS JSTD-M15A
Product Name: Marine / Shipboard Thermal-Magnetic Circuit Breaker — JSTD Series (JSTD-M15A)
Product Introduction: Compact miniature circuit breaker (MCB/MCCB class) manufactured by Japan Radio Co., Ltd. (JRCS) for marine and offshore power distribution systems; designed to IEC/ISOmarine standards for protecting 15 A rated branch circuits in shipboard AC/DC low-voltage panels.
Yaskawa JGSM-06
Bender IRDH275B-435&IRDH275BM-727
Product Introduction: Continuously monitors the insulation resistance (to earth/PE) of unearthed power distribution systems (IT systems) using Bender's AMPPlus® adaptive pulsed measuring principle; detects first insulation fault without tripping the system, enabling safe continued operation with alarm notification.
Motorola IPMC761
Product Name: VMEbus Single Board Computer (SBC) / Processor Module — IPMC761
Product Introduction: VMEbus-compatible embedded controller based on Motorola 68000-series (MC68020/MC68030) architecture; intended as a CPU/node controller in VME chassis for industrial automation, defense/aerospace, and telecommunications systems running RTOS such as VxWorks or pSOS.
Metso IOP371
Product Name: S800 I/O RTD (Resistance Temperature Detector) Input Module — IOP371
Product Introduction: 8-channel RTD input module for Valmet DNA / Metso S800 distributed I/O system; provides high-accuracy temperature measurement with full channel-to-channel and channel-to-bus isolation, supporting 2-, 3-, and 4-wire RTD connections.
Compressor Controls Corp IOC-555-D I7-550555-001
Product Name: Simplex I/O Communication & Processor Module for Turbo-Machinery Control
Product Introduction: Integrated main-processor and I/O module designed for CCC Series 5 / Vanguard / Reliant compressor and turbine control systems; executes anti-surge, performance control, and surge-prevention algorithms while providing local field I/O interfacing.
Vibro-Meter IOC4T 200-560-000-016
Product Name: VM600 Series Input/Output Conditioning Card (IOC4T)
Product Introduction: Signal conditioning and interface I/O card for the VM600 machinery protection system; works in pair with MPC4 dynamic protection cards to acquire dynamic vibration signals and tachometer signals from proximity probes, accelerometers, and speed sensors.
Alstom ICP232 029.359325
Product Name: ICP232 VME-based Control & Communication Interface Module (Controller Motherboard)
Product Introduction: Industrial controller board with integrated VME bus, Ethernet, CAN bus, and serial ports; serves as the central processing and communication node in Alstom/Converteam drive systems, wind turbine pitch controls, and power conversion equipment.
ProSoft Technology ILX34-MBS485
Product Name: Modbus Serial Communication Module for Allen-Bradley 1734 Point I/O & CompactLogix L1
Product Introduction: Slot-in RS-485 Modbus RTU/ASCII master or slave module that bridges serial field devices (meters, VFDs, sensors) into Rockwell EtherNet/IP or ControlNet architectures via the 1734 Point I/O backplane. No external gateway required.
MOXA ICF-1280I-M-ST-T
Manufacturer: Moxa Inc. (Taiwan)
Product Brief: Converts a standard PROFIBUS DP RS-485 electrical segment to a fiber-optic link, providing galvanic isolation, noise immunity, and extended distance. Intended for connecting PROFIBUS masters/slaves across electrically noisy or geographically separated areas in industrial plants.
GE IC660EBD024
Manufacturer: GE Fanuc Automation / GE Vernova (Legacy Series 90-30 Genius I/O)
Product Brief: Intelligent block I/O module that operates on the GE Genius Bus. Each of the 16 points can be individually configured as input or output (source/sourcing type), accepts 24 V DC or 48 V DC field voltage, and reports diagnostics back to the Genius bus master (PLC or host). Often paired with IC660BBD024 terminal base.