ProSoft MVI56-MNETR Modbus TCP

  • Technical Specifications
    • Mechanical and Power Parameters
      • It adopts a single-slot design compatible with the Controllogix 1756 backplane, enabling easy installation into Controllogix chassis without occupying excessive space.
      • The backplane current load reaches 800 mA under 5 VDC and 3 mA under 24 VDC, matching the power supply requirements of Controllogix systems for stable operation.
    • Communication Parameters
      • It is equipped with a 10/100 Mbps Ethernet interface with auto-crossover detection, using an RJ45 connector suitable for Cat5 cables, and it supports Ethernet/IP pass-through communication.
      • It supports storage and transfer of up to 5000 16-bit registers with the Controllogix processor through block transfer or side-connect interface. Client parameters are configurable, including a minimum response delay ranging from 0 to 65535 milliseconds, and it also supports floating-point data types.
    • Environmental and Display Parameters
      • The operating temperature ranges from 0 °C to 60 °C, and the storage temperature ranges from -40 °C to 85 °C. It can operate normally in 5% to 95% relative humidity environments without condensation.
      • It is equipped with a 4-character scrolling alphanumeric LED display that shows module version, IP address, application port settings and error information, along with LED indicators for module status, application status and error status.

ProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Network Interface Module for ControlLogix

  • Technical Specifications
    • Power and Physical Parameters
      • It is compatible with the 1756 backplane and occupies a single slot. The backplane current load is 800 mA at 5.1 VDC and 3 mA at 24 VDC, matching standard ControlLogix chassis power supply configurations.
      • The operating temperature range is 0°C to 60°C, and the storage temperature range is -40°C to 85°C. It can operate normally in an environment with 5% to 95% relative humidity without condensation.
      • It resists 30g operational shock and 50g non-operational shock, and can withstand 5g vibration within the frequency range of 10Hz to 150Hz, adapting to harsh industrial site conditions.
    • Communication Parameters
      • It supports all standardized PROFIBUS baud rates, with the maximum baud rate reaching 12 Mbps, meeting the requirements of high-speed data transmission in industrial scenarios.
      • It can connect up to 125 slave devices and can access PROFIBUS PA slaves through DP/PA couplers or links. It also allows multiple master modules to be installed in a single rack to expand network capacity.
      • It is equipped with an RS-232 configuration port with an RJ45 interface, and comes with an RJ45 to DB-9 male cable for on-site configuration and debugging.
    • Software Compatibility Parameters
      • It works with ProSoft Configuration Builder software, supporting functions such as importing project-specific GSD files and automatic bus parameter calculation.
      • It uses ladder logic for data transfer between the module and the processor, and a sample ladder file with add-on instructions is provided to simplify the configuration process for users.
      • It supports communication with configuration software via Ethernet routing through Rockwell Automation Ethernet interfaces such as 1756-ENBT and 1756-EN2T.

ProSoft MVI56-PDPS PROFIBUS DP Slave Communication Module for ControlLogix

Technical Specifications
  • Mechanical and Power Parameters
    • It adopts a single-slot design compatible with the ControlLogix 1756 backplane, supporting installation in both local and remote ControlLogix racks.
    • The power consumption parameters match ControlLogix chassis requirements: 5 VDC backplane current draw is 800 mA, and 24 VDC current draw is 3 mA, ensuring stable operation without overloading the chassis power supply.
  • PROFIBUS DP Communication Parameters
    • It complies with PROFIBUS DP V0 and V1 standards, supporting baud rates ranging from 9.6 kbps to 12 Mbps for flexible network configuration.
    • The module supports up to 244 bytes of input data and 244 bytes of output data for cyclic communication. For acyclic communication, it supports PROFIBUS DP V1 services, including parameterization, diagnosis and alarm handling.
    • It is equipped with a standard DB9 male PROFIBUS DP connector, compatible with standard PROFIBUS DP cables and connectors, and supports PROFIBUS DP slave addressing from 0 to 125.

ProSoft MVI56E-MNET

Product Name:​ Enhanced Modbus TCP/IP Client/Server Communication Module for ControlLogix.
Product Introduction:​ Single-slot 1756 backplane co-processor that bridges Rockwell ControlLogix PLCs to Modbus TCP/IP Ethernet networks. It runs an embedded RTOS on an ARM Cortex-A8 800 MHz CPU, mapping Modbus registers directly into Logix tag memory through ProSoft AOI instructions without occupying PLC scan time.

ProSoft MVI56E-MNETCR

Product Name:​ ControlLogix Modbus TCP/IP + Serial Multi-Protocol Enhanced Module with Conformal Coating (CR variant).
Product Introduction:​ Variant of MVI56E-MNET adding two fully isolated RS-232/422/485 serial ports alongside one 10/100 RJ45, enabling parallel Modbus RTU/ASCII, DF1 and Modbus TCP conversion in one slot.

ProSoft MVI56E-MNETXT

Product Introduction:​ The MVI56E-MNETXT is a single-slot 1756 backplane co-processor built for Rockwell ControlLogix platforms operating in corrosive, wide-temperature or high-altitude sites. It delivers the same Modbus TCP/IP client/server engine as the standard MVI56E-MNET but adds industrial-grade PCB conformal coating and a -25 °C to +70 °C operating envelope, qualifying it for Logix-XT installations such as desert solar pumping, offshore topside panels, arctic pipeline RTU shelters and steel-mill drive rooms. The module runs an independent embedded processor and never consumes ControlLogix scan time for socket handling.

ProSoft MVI56E-PDPMV1

Product Name:​ PROFIBUS DP-V1 Master Network Interface for ControlLogix.
Product Introduction:​ Single-slot 1756 module acting as a certified PROFIBUS DP-V1 master (IEC 61158) to poll DP-V0/V1 slaves (drives, I/O, encoders) and present cyclic I/O plus acyclic parameter data to the Logix processor asynchronously.

ProSoft MVI56E-SIE

Product Introduction:​ The MVI56E-SIE bridges Rockwell ControlLogix PACs to Siemens S7-200/300/400/1200/1500 controllers over ISO-on-TCP (RFC1006 S7comm). The Logix side sees it as a single 1756 I/O module; the Siemens side sees up to 20 independent S7 client connections originating from the ProSoft module IP. All socket management, TSAP negotiation and PUT/GET scheduling run on the module CPU, leaving ControlLogix scan untouched.

ProSoft MVI69-MNET Modbus TCP

  • Technical Specifications
    • Power and Mechanical Parameters
      • It has a maximum current load of 800 mA at 5 VDC power supply. It adopts a standard 1769 single-slot design and is compatible with the 1769 backplane, which can be smoothly installed into the corresponding CompactLogix chassis.
      • It is recognized as a standard input and output module by the CompactLogix system, enabling unobstructed access to processor memory for smooth data transfer between the processor and the module.
    • Communication Parameters
      • It is equipped with a 10/100 Base-T Ethernet-compatible interface. The server driver can support connections to up to five Modbus TCP/IP clients through service port 502 with standard MBAP messaging, and another five clients through Modbus RTU/ASCII on service port 2000.
      • The client driver can actively read and write data with Modbus TCP/IP-compatible devices, and a single client can support up to 100 commands that can be sent to one or multiple servers. All data mapping of the module starts from Modbus register 40001.
    • Compatibility Parameters
      • It is compatible with all CompactLogix and MicroLogix 1500 LRP controllers, but it cannot be used with 1769-QBFC1B, 1769-L16X and 1769-L18X models. It supports Enron, Daniels and other floating-point data types to meet diverse data processing needs.

ProSoft MVI69-PDPMV1

Product Overview The MVI69-PDPMV1 is a PROFIBUS DP-V1 master module designed by ProSoft Technology for Rockwell Automation's CompactLogix and MicroLogix PLCs. It serves as a bridge connecting PLCs to PROFIBUS network slave devices, enabling data exchange and control. This module is widely used in industrial automation systems to integrate devices from different manufacturers. Technical Specifications
  • Interface: PROFIBUS DP-V1

ProSoft MVI94-GSC Flex I/O Generic Serial Communication Module

  • Technical Specifications
    • Mechanical and Power Parameters
      • It adopts DIN rail installation mode, with dimensions of 120mm x 80mm x 40mm and a weight of about 200g, featuring a compact structure that saves installation space.
      • The power supply range is 9 - 30V DC, meeting the power demand of most industrial on-site power supply systems, and its enclosure protection level reaches IP20.
      • The operating temperature range is -40°C to 85°C, which enables it to operate stably in extreme temperature environments such as cold workshops and high-temperature industrial sites.
    • Communication Parameters
      • It supports multiple communication protocols including RS-232, RS-422, RS-485, ASCII, Modbus RTU and Modbus TCP/IP, covering most serial communication needs in industrial fields.
      • The maximum baud rate can reach 115.2 kbps, and it supports flexible configuration of parameters such as data bits and stop bits to match different serial device communication requirements.
      • It is equipped with a single-slot interface that supports ASCII communication, and is built with a 4096-character data buffer to ensure the stability of data transmission and avoid data loss due to transmission delays.
    • Compatibility Parameters
      • It is fully compatible with Allen-Bradley ControlLogix and CompactLogix series PLCs, and can be perfectly integrated into the corresponding control system architectures.
      • It is compatible with various serial industrial devices such as bar code readers, scales, terminals and printers, without requiring additional adaptation accessories during connection.

ProSoft MVI94-MCM-MHI

Product Introduction:​ The MVI94-MCM-MHI is a single-width 1794 Flex I/O module that gives a Flex processor Modbus RTU/ASCII master or slave capability plus a MHI (Mitsubishi Heavy Industries) serial drive-highway driver, allowing direct polling of MHI-spec cranes, hoists and legacy drive controllers without an external protocol converter. Data moves asynchronously between the Flex backplane and the serial field, driven by simple ladder logic.