HIMA H4135A

Product Introduction:
A SIL 3-certified programmable safety module from HIMA, serving as the central processing unit in Emergency Shutdown (ESD), Fire & Gas (FGS), and machine protection systems across process industries.
Category:
Description
Technical Specifications & Performance Parameters:
  • Order Number:​ 992413560
  • Safety Integrity:​ SIL 3 (IEC 61508/61511), Cat. 4 (ISO 13849)
  • Architecture:​ QMR (Quadruple Modular Redundancy) / TMR support
  • Processor:​ High-performance safety microcontroller (e.g., NXP MPC864xD-class dual-core in related platforms)
  • I/O Capacity:​ Supports large-scale digital/analog expansion (e.g., 16 ch base, up to 500+ in config)
  • Cycle Time:​ Approx. 1500 μs (controller dependent)
  • Power Supply:​ 24 V DC (via backplane)
  • Operating Temperature:​ -40 °C to +71 °C (typical -20 to +60 °C)
  • Protection:​ IP20 (control cabinet)
  • Indicators:​ Run, Fault, Comms LEDs on front
Functional Features:
  • Millisecond-level fault detection and safe-state transition
  • Built-in self-diagnostics for CPU, memory, communication
  • Majority voting redundancy masking single/multiple faults
  • Compatible with Modbus, Profibus, Ethernet system bus
Application Scenarios:
  • Oil refining, petrochemical plants, natural gas pipelines
  • Power generation (thermal, hydro), pharmaceutical batch control
  • Rail transit safety loops, critical machine safeguarding
Structure & Material:
  • Printed circuit board with conformal coating inside metal/plastic framed module
  • 19-inch rack or DIN rail backplane mounting
Working Principle:
Continuously scans safety I/O, runs certified safety application logic, performs cross-checking between redundant processors, and forces outputs to predefined safe state upon detecting divergence or internal fault.
Installation Requirements:
  • Install in grounded control cabinet with adequate clearance for airflow
  • Use only HIMA-approved backplanes and power supplies
  • Ensure proper termination of communication buses
Usage Precautions:
  • Never bypass safety wiring during commissioning
  • Maintain firmware/toolchain version consistency
  • Log all changes to safety logic with change-control documentation
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “HIMA H4135A”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.