Universal analog signal isolation and conversion module under Schneider automation control product line, converts various industrial field analog sensor signals into standard unified analog signals for PLC system acquisition, with full electrical isolation between field side and control cabinet side circuits.
Category:
Description

Technical Specifications

  • Input Signal Supported: 4-20mA current, 0-10V voltage, 0-5V voltage, PT100 thermal resistance
  • Output Standard Signal: Isolated 4-20mA / 0-10V configurable single channel output
  • Isolation Voltage Strength: 2500V AC galvanic isolation between input, output and power supply
  • Power Supply Input: 24V DC ±10% industrial control power supply
  • Signal Conversion Accuracy: ±0.1% full scale total error
  • Operating Temperature Range: -10°C ~ +60°C
  • Response Conversion Speed: ≤100μs full signal conversion cycle
  • Mounting Standard: 35mm standard DIN rail modular installation

Functional Features

  1. Multi-type sensor signal compatible single-channel signal conditioning design
  2. Three-way complete galvanic isolation eliminates ground loop interference in distributed field wiring
  3. Front panel DIP switch one-click switching of input and output signal types without software configuration
  4. Built-in overvoltage, overcurrent, reverse power connection hardware protection circuit
  5. LED power running indicator and signal status indicator on front panel
  6. Ultra-narrow modular width saves electrical cabinet installation space

Performance Parameters

  • Linear Conversion Deviation: ≤0.05% full scale
  • Temperature Drift Coefficient: 0.005% FS / °C
  • Power Consumption Under Full Load: Max 1.2W
  • Dielectric Isolation Withstand Time: 60s continuous 2500V AC without breakdown
  • Electromagnetic Compatibility: Compliant IEC61000-6-2 industrial heavy EMC standard

Material Composition

  • Module Housing: UL94-V0 flame retardant PA66 plastic
  • Internal Circuit Board: Four-layer FR-4 isolation circuit board with isolated transformer winding
  • Terminal Blocks: Spring cage fast wiring copper terminals with plastic insulation shell
  • Isolation Transformer: Epoxy sealed miniature isolation magnetic core

Structural Characteristics

  1. Narrow slim DIN rail modular single channel independent unit
  2. Front panel integrated signal type DIP switches, two status indicator LEDs
  3. Left terminal zone for 24V DC power supply wiring, right terminal zone for field input and control output wiring
  4. Internal isolation transformer separates input, output and power three electrical domains completely
  5. Integral rear DIN rail buckle structure for quick disassembly and replacement

Working Principle

Receives non-standard analog signal from field temperature, pressure, flow sensor; isolates input signal via internal isolation transformer to cut off ground loop conduction path; high-precision operational amplifier circuit linear converts raw sensor signal into unified standard 4-20mA or 0-10V signal; isolated output signal transmits to PLC analog input module; protection circuit automatically clamps circuit voltage/current within safe threshold when wiring reverse connection or surge voltage occurs.

Advantage Highlights

  • Three-way 2500V high isolation solves distributed industrial field ground loop interference failure
  • Multi-signal universal design reduces spare parts inventory types for automation maintenance
  • DIP switch local configuration without programming software, on-site rapid parameter switching
  • Ultra-high conversion accuracy meets precision process monitoring measurement requirements
  • Compact narrow module greatly improves cabinet wiring density and space utilization

Applicable Industries

Process chemical automation, water quality monitoring systems, food pharmaceutical process control, HVAC building automation, new energy photovoltaic power station monitoring, hydraulic pressure detection equipment

Model Series Belonging

Schneider C200 Series Modular Signal Isolators; C2001011100 represents single-channel universal input configurable analog isolator base model

Installation Requirements

  1. Snap onto standard 35mm top hat DIN rail inside sealed automation control cabinet
  2. Maintain minimum 5mm horizontal clearance between adjacent signal isolation modules for heat dissipation
  3. Use shielded twisted pair cable for field sensor signal wiring, single-point grounding of shielding layer
  4. Supply stabilized 24V DC industrial control power without ripple voltage exceeding 240mV
  5. Install away from frequency converter, contactor and other high electromagnetic interference components with ≥10cm spacing

Operation Precautions

  1. Do not connect AC voltage signal to DC analog input terminal, internal circuit will suffer permanent burnout
  2. Adjust DIP switch signal type only after cutting off 24V DC power supply
  3. Avoid continuous operation at ambient temperature above +60°C, will increase conversion drift error
  4. Prevent conductive metal debris falling into terminal wiring area during cabinet maintenance
  5. Verify input/output signal wiring definition via factory wiring diagram before power-on test run
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Schneider C2001011100”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.