Technical Specifications:
- Input Types: Type J, K, T, E, S, R, B Thermocouples; Pt100, Pt1000, Cu50, Cu100 RTDs; 0–20 mA, 4–20 mA, 0–10 V, 1–5 V
- Display: Monochrome backlit LCD, 6-digit, 14 mm digit height
- Accuracy: ±0.1% of reading + 1 digit (for mA/V inputs); ±0.5% of span (for TC/RTD inputs)
- Sampling Rate: 2 readings per second (typical)
- Record Memory: 4000 data points with timestamp (date and time)
- Alarm Setpoints: 2 alarm setpoints (Hi and Lo) with relay outputs
- Power Supply: 85–265 V AC / 90–300 V DC / 24 V DC (universal)
- Operating Temperature: 0°C to +55°C (+32°F to +131°F)
- Protection Rating: IP65 front panel (NEMA 4X equivalent when panel-mounted)
- Dimensions: 96 mm x 48 mm x 75 mm (W x H x D)
- Cutout Size: 92 mm x 45 mm
Functional Features:
- Universal Input Acceptance: Accepts all major thermocouple types, RTD types, and standard analog signals
- Trend Recording: Stores up to 4000 timestamped readings in non-volatile memory
- Dual Alarm Outputs: 2 SPDT relay outputs for High and Low alarm conditions
- Peak/Valley Hold: Captures and holds maximum and minimum process values
- Max/Min/Avg Display: Shows statistical process data on demand
- Retransmission: Isolated 4–20 mA retransmission output (optional)
Material Composition:
- Front Bezel: Polycarbonate (Lexan), UV-resistant, flame-retardant UL 94 V-0
- Housing: ABS plastic with IP65 gasket seal
- LCD Cover: Scratch-resistant polycarbonate with anti-glare coating
- Terminal Block: Phosphor bronze, tin-plated
Structural Characteristics:
- Form Factor: 1/8 DIN panel-mount instrument
- Mounting: Panel cutout with snap-in mounting clips
- Weight: Approximately 200 grams
- Display Area: 68 mm x 28 mm visible display window
Working Principle:
The RH101AA receives the process signal via its universal input terminals. The input signal is digitized by a 16-bit ADC and scaled to engineering units using user-configurable range parameters. The processed value is displayed on the LCD. Every 0.5 seconds, the value is stored in non-volatile EEPROM memory with a timestamp. When the process value crosses either alarm setpoint, the corresponding SPDT relay changes state to activate external alarm devices.
Advantages / Highlights:
- Universal input compatibility eliminates need for multiple instrument types
- Non-volatile trend memory retains data during power loss
- Large 14 mm digits for excellent visibility from distance
- IP65 front panel provides protection against washdown environments
- Universal power supply (85–265 V AC) simplifies inventory management
Applicable Industries:
- Food and Beverage Processing
- Pharmaceutical Manufacturing
- HVAC and Building Automation
- Water Treatment
- Light Industrial Process Control
Installation Requirements:
- Cut 92 mm x 45 mm opening in the control panel
- Mount using included snap-in clips from the rear of the panel
- Connect field wiring to screw-clamp terminal block (max 2.5 mm² wire)
- For alarm relay outputs, connect external devices to terminals AL1 and AL2
- Ensure minimum 50 mm clearance behind the panel for wiring access
- Connect power to terminals L and N (AC) or + and – (DC)
Usage Precautions:
- Do not exceed the maximum input voltage of 50 V DC on mV/mA inputs
- For thermocouple inputs, use correct thermocouple extension wire to avoid measurement errors
- Cold junction compensation (CJC) is automatic; do not disable it
- Do not open the housing while powered — risk of electric shock
- Clean the front bezel with damp cloth only; do not use solvents
Reviews