Triconex 3009 Enhanced Main Processor (UMP) Module

Technical Specifications
  • Processor and Memory Parameters
    • It is equipped with an Intel Core i7 - 4790 or PowerPC 604e processor, with a main frequency of up to 1.3 GHz, which can efficiently support the operation of complex control algorithms and large - scale system data processing.
    • It supports a maximum of 16GB DDR3L RAM, and is configured with a 2GB SSD for storage, which can stably store a large number of control programs, configuration parameters and real-time operation data of the system.
  • Power and Environmental Parameters
    • The input voltage is 24V DC, the output voltage is 5V DC, and the maximum power consumption is 22W, which meets the power supply standards of industrial control systems.
    • The operating temperature range is -40°C to +70°C, and the storage temperature range is -40°C to +85°C. It can adapt to the extreme temperature changes of most industrial sites.
    • It can work normally in an environment with a humidity of 5% to 95% non-condensing, has an anti - shock capacity of 30g (11ms) and an anti - vibration capacity of 5g (10 - 150Hz).

Triconex 3101 Tricon Main Processor Module

Technical Specifications
    • Processor and Memory Parameters
      • It is equipped with a 32-bit Motorola MPC860 processor running at a clock speed of 50 MHz, which efficiently supports the operation of complex control logic.
      • It is configured with 6MB Flash PROM for stable storage of application programs, 16MB DRAM for running programs and storing sequence of events data, and 8KB NVRAM dedicated to maintaining variables.
    • I/O and Power Parameters
      • It is equipped with 8 digital input channels, 8 digital output channels, 4 analog input channels, and 4 analog output channels. It supports input types such as dry contacts, photoelectric signals and analog signals, and output types including relays and transistors.
      • The digital output current reaches 500mA, the typical input voltage is 24V DC, and some models can support 5V DC input. The module has a rated power of 12W.

Triconex 3201 Communication Module

Technical Specifications
  • Communication Port Parameters
    • It is equipped with three configurable RS - 232/485 serial ports and two Ethernet ports. Some versions can be configured with four serial ports, with a total data transmission rate of 460.8 kilobits per second for all serial ports.
    • The two Ethernet ports include 802.3 copper Ethernet ports and fiber - optic Ethernet ports in different models, with the Ethernet transmission speed reaching 100Mbps.
    • The first serial port can support Modbus or Trimble GPS interface, and the fourth serial port can be configured as Modbus or Tristation interface.
  • Power and Electrical Parameters
    • The nominal input voltage is 24V DC, and the working voltage range is 19.2V DC to 30V DC, which can tolerate 5% AC ripple.
    • The maximum power interruption time allowed from the nominal voltage is 1 millisecond, the minimum repetition rate of power interruption is 1 second, and the maximum logic power consumption of the module is 8 watts.

Triconex 3201 Communication Module

Technical Specifications:
  • System Architecture: The 3201 model is part of a triply redundant architecture, offering fault tolerance and high availability. This triple modular redundancy (TMR) ensures continuous operation even in the event of hardware failures.
  • Processor Capabilities: Equipped with powerful processors capable of executing complex control logic and diagnostics simultaneously across three channels to ensure reliable operation.
  • Memory: Includes sufficient memory for storing application programs, historical data, and system parameters, supporting extensive configuration and logging capabilities.
  • Communication Interfaces: Supports various communication protocols including Modbus, OPC, and proprietary interfaces, enabling seamless integration with distributed control systems (DCS) and other plant networks.

TRICONEX 3311 Digital Input Module

Technical Specifications
  • Input Channels: 16 independent digital input channels
  • Input Voltage Range: 18–32 VDC (typical 24 VDC)
  • Input Current: ≤6 mA per channel
  • Input Types: Dry contact or wet contact signals
  • Channel Isolation: Each input channel is isolated from the system bus
  • Redundancy Design: TMR (Triple Modular Redundant) input paths per channel
  • Response Time: ≤5 ms (including filtering)
  • Diagnostic Functions: Line monitoring, open-circuit detection, short-circuit detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Humidity Range: 5%–95% RH (non-condensing)
  • Weight: Approximately 1.2 kg
  • Mounting: Mechanically locked to prevent misinstallation
  • Certifications: SIL 3 (IEC 61508), TÜV Rheinland-certified

Triconex 3351 Analog Input (AI) Module

Technical Specifications
  • Input and Signal Parameters
    • The analog input version has 32 shared points, with a nominal input current of 4 - 20mA DC and an operating current range of 2 - 22mA DC. It has a 16-bit resolution and an accuracy of ±0.01% within the 1000 - 20000Hz frequency range.
    • The pulse input version has 8 high-frequency input points, a pulse count measurement resolution of 1 microsecond, and an input diagnostic fault range of 0.5% of the full scale. The input change sampling cycle is the longer one between one scan and 210 milliseconds.
    • The module has an input bandwidth of 16Hz, an absolute maximum field voltage of 33V DC, and an absolute maximum reverse field voltage of -0.6V DC.
  • Power and Electrical Parameters
    • The nominal power supply voltage is 24V DC. The minimum isolation between functional and protective earth is 500V DC, and the minimum isolation between functional and functional earth is 800V DC.
    • The module has a source impedance of 180Ω, an input impedance of 250Ω when paired with a baseplate, and a 100Ω I-to-V resistor with a tolerance of ±0.01%.

Triconex 3401 Digital Output Module

Technical Specifications
  • Output and Signal Parameters
    • The nominal output voltage is 24V DC, and the operating voltage range is 15 - 30V DC, with an absolute maximum output voltage of 33V DC and an absolute maximum reverse input voltage of -0.6V DC.
    • In switching mode, the maximum output current is less than 4.8A with self-limiting function, and the typical value is 3A; in carry mode, the minimum output current is more than 0.7A with self-limiting function, and the typical value is 1.5A.
    • The loop-back threshold is 0 - 5V DC for the off state, 6 - 14V DC for the transition state, and 15 - 30V DC for the on state, and the off-state leakage current to the load is less than 1mA.
  • Power and Isolation Parameters
    • The minimum isolation voltage between functional circuit and protective ground is 500V DC, and the minimum isolation voltage between functional circuit and functional logic ground is 800V DC, which can effectively prevent electrical interference from affecting the normal operation of the module.
    • The voltage drop in the on-state is less than 1V DC when the current is 1.5A, which reduces the energy loss during signal transmission and ensures the efficiency of power utilization.

TRICONEX 3415

Technical Specifications
  • Redundancy: TMR design with three independent channels for fault tolerance.
  • Safety Integrity Level (SIL): SIL 3 certified, suitable for high-risk applications.
  • I/O Capacity: Supports up to 70 I/O points (varies by module type).
  • Processor: 32-bit CPU per channel, 50 MHz clock speed.
  • Memory: 16 MB RAM per channel for complex logic execution.
  • Communication: Ethernet, RS-232, RS-485, and Modbus protocols for integration with DCS or HMI systems.
  • Operating Temperature: -20°C to +60°C (industrial-grade reliability).
  • Power Supply: Dual redundant power inputs for uninterrupted operation.
  • Certifications: TÜV Rheinland-certified, compliant with IEC 61508, ISA S84.01, and NFPA 72.

TRICONEX 3451 Remote Terminal Unit/Relay Output Module

Technical Specifications
  • Output Channels: 32 independent relay output channels
  • Relay Type: Form A (SPST-NO) dry contact outputs
  • Voltage Rating:
    • Maximum: 30 VDC / 250 VAC
    • Recommended: 24 VDC (common industrial standard)
  • Current Rating: 2 A (resistive load per channel)
  • Channel Isolation: Each channel is electrically isolated from the system bus
  • Response Time: ≤10 ms
  • Redundancy: TMR architecture with three independent channels per output
  • Fault Tolerance: Single-channel failures do not disrupt operation; hot-swapping supported
  • Communication: Compatible with Ethernet, RS-232, RS-485, and Modbus protocols
  • Certifications: SIL 3 (IEC 61508), TÜV Rheinland-certified
  • Operating Temperature: -20°C to +60°C
  • Mounting: Plug-in module with dedicated base for secure installation

Triconex 3481 Analog Output Module

Technical Specifications
  • Output and Signal Parameters
    • It has 4 common - return, DC - coupled output channels, with a 12 - bit resolution and an output accuracy of less than 0.25% of the full - scale range within the 4 - 20mA controlled current range.
    • The output current can reach an over - range of 0 - 22mA and also has a 0mA output capability, with a step function response time of less than 2ms.
    • The typical switch time when a channel fails is 1ms, and the maximum switch time does not exceed 3ms.
  • Power and Loop Parameters
    • The nominal external loop power supply is 24V DC, and the maximum allowable voltage is 32V DC, with reverse voltage protection.
    • For a 300Ω load, the loop power supply needs to be over 16V DC with a minimum current of 1A; for an 800Ω load, the loop power supply must be over 28V DC with a minimum current of 1A.
    • It has continuous over - range protection against 36V DC and 0V DC, which effectively protects the internal circuitry from damage due to abnormal voltage.

TRICONEX 3501E Digital Input Module

Technical Specifications
  • Input Channels: 32 isolated, non-shared digital inputs
  • Input Voltage: 115 VAC/DC (90–155 VAC/DC range)
  • Switching Level:
    • On: >86 VAC/DC
    • Off: <28 VAC/DC
  • Frequency Range: DC or 47–63 Hz
  • Hysteresis: Typical 32 VAC/DC
  • Response Time: Sub-millisecond for signal detection
  • Isolation: Each channel is electrically isolated from the system bus
  • Redundancy: TMR design with three independent channels per input
  • Certifications: SIL 3 (IEC 61508), TÜV Rheinland-certified
  • Operating Temperature: -40°C to +70°C (-40°F to 158°F)
  • Weight: Approximately 3 kg
  • Mounting: DIN rail or panel-mounted

TRICONEX 3501E Digital Input Module

Technical Specifications
  • Input Channels: 32 isolated, non-shared digital inputs
  • Input Voltage: 115 VAC/DC (90–155 VAC/DC range)
  • Switching Level:
    • On: >86 VAC/DC
    • Off: <28 VAC/DC
  • Frequency Range: DC or 47–63 Hz
  • Response Time: Sub-millisecond for signal detection
  • Hysteresis: Typical 32 VAC/DC
  • Isolation: Each channel is electrically isolated from the system bus
  • Redundancy: TMR design with three independent channels per input
  • Certifications: SIL 3 (IEC 61508), TÜV Rheinland-certified
  • Operating Temperature: -40°C to +70°C (-40°F to 158°F)
  • Weight: Approximately 3 kg
  • Mounting: DIN rail or panel-mounted