Technical Specifications:
- Input Channels: 2 universal inputs (independent, high-accuracy)
- Input Types: Type J, K, T, E, S, R, B TC; Pt100, Pt1000 RTD; 4–20 mA (HART); 0–10 V; 1–5 V
- Display: Dual-line 6-digit red LED, 14 mm digits, 200,000 count resolution
- Accuracy: ±0.05% of span (mA/V); ±0.2% of span (TC/RTD) — superior to standard RH900 series
- Recording Memory: 16,000 data points per channel with full date/time stamp
- Recording Interval: 0.5 s to 60 s (configurable)
- Communication: HART 7 + RS-485 Modbus RTU
- Alarm Outputs: 2 SPDT relays per channel, 250 V AC / 30 V DC, 3 A
- Retransmission: Isolated 4–20 mA per channel (HART pass-through)
- Power Supply: 85–265 V AC / 90–300 V DC / 24 V DC
- Operating Temperature: -10°C to +55°C (+14°F to +131°F)
- Protection Rating: IP65 front panel
- Dimensions: 96 mm x 96 mm x 95 mm (W x H x D)
- Cutout Size: 92 mm x 92 mm
- Weight: Approximately 480 grams
Functional Features:
- High-Resolution ADC: 24-bit sigma-delta ADC provides 200,000 count resolution
- Extended Recording: 16,000 points per channel — double the memory of RH916RB
- HART + Modbus Dual Communication: Full device diagnostics and DCS integration
- 4 Latching Alarm Relays: With independent hysteresis per channel
- Statistical Display: Per-channel Max, Min, Avg, Peak, Valley
Material Composition:
- Front Bezel: Flame-retardant ABS, precision-molded matte black
- Housing: Polycarbonate (Lexan), IP65 gasket-sealed
- Display: High-brightness red LED, optical-grade polycarbonate, anti-reflective
- Terminals: Phosphor bronze, gold-plated for high-accuracy signal integrity
- PCB: FR-4 with gold-plated traces on critical signal paths
Structural Characteristics:
- Form Factor: 96 x 96 mm panel-mount (1/4 DIN)
- Display Layout: Top line = Channel 1; Bottom line = Channel 2
- Keypad: 8-button membrane with dedicated HART and recording menu access
- Connectors: RJ-11 (RS-485), screw terminals (HART), screw terminals (power/I/O)
Working Principle:
The 24-bit sigma-delta ADC samples each input channel at high resolution, providing 200,000 counts for precise measurement. The microcontroller applies per-input-type linearization tables stored in firmware. Values are displayed on the dual LED lines. Every 0.5 seconds (minimum interval), the value is timestamped and stored in 16,000-point EEPROM memory. HART communication decodes diagnostics from field devices; Modbus RTU provides standard DCS communication. Alarm comparators with user-adjustable hysteresis (0.1% to 10% of span) drive the SPDT relays.
Advantages / Highlights:
- ±0.05% accuracy on mA/V inputs — the highest in the RH900 series
- 16,000-point trend memory provides the longest recording duration in the series
- HART communication enables field device diagnostics without removing the transmitter
- Gold-plated terminals ensure signal integrity for high-accuracy applications
- IP65 front panel with gasket seal for washdown environments
Applicable Industries:
- Oil and Gas (custody transfer, fiscal metering)
- Chemical Processing (precision dosing)
- Power Generation (boiler control, turbine monitoring)
- Pharmaceutical (GMP-compliant processes)
- Semiconductor Manufacturing
Installation Requirements:
- Cut 92 mm x 92 mm panel opening
- Mount with IP65 gasket and snap-in clips
- Use shielded twisted pair cable for all analog and HART connections
- RS-485: connect A, B, GND; install 120 Ω termination at bus ends
- Provide 85–265 V AC or 24 V DC power
- For HART: ensure 250 Ω loop resistor is present in the DCS I/O card
- Set Modbus address via DIP switches (unique per device on bus)
Usage Precautions:
- Do not apply > 50 V DC to any mA/V input terminal
- HART communication requires proper loop resistance (250 Ω) — verify before use
- Calibration verification recommended every 12 months for ±0.05% accuracy claims
- Do not open housing during operation — risk of electric shock and accuracy void
- Recording memory fills at 16,000 points — configure recording interval to match data retention requirements