Triconex 9573-110F Analog Input Communication Module

Technical Specifications
  • Signal Processing Parameters
    • It can convert small signals based on high common - mode voltage into single - ended signals relative to the system chassis ground, which effectively solves the interference problem of high common - mode voltage on signal transmission.
    • The built - in isolation amplifier can amplify weak analog input signals. The signal filtering function can filter out external noise, and the measurement resolution and accuracy of analog signals are significantly improved after processing.
    • It supports 8 PI points and 16 PTI points, which can meet the collection and processing needs of multiple groups of analog signals at the same time.
  • Physical Parameters
    • It adopts a standard industrial control card design, which is consistent with the installation size of Triconex series module slots. It can be directly inserted into the dedicated position of the Triconex system chassis for installation.
    • The module uses a hard metal shell, which has good physical protection performance. The wiring interface adopts a standard terminal design, which facilitates firm connection with field sensors and internal system lines.

Triconex 9662-610 Standard Termination Panel

Technical Specifications
  • Electrical Parameters
    • It adopts 24 VDC termination option and has an input voltage range of 0 to 55 VDC, which can adapt to the voltage requirements of different field digital output devices.
    • The long - term drift is less than 0.3%, and the frequency range covers 14 to 60 kHz, ensuring the stability of signal transmission.
    • The maximum power consumption of the panel is 10 W, which will not cause excessive power load to the overall safety system during long - term operation.
  • Physical Parameters
    • Its overall dimensions are 12.7 cm × 12.7 cm × 5.1 cm, and the weight is 0.3 kg. The compact size allows it to be installed in control cabinets with limited space.
    • It adopts DIN rail installation mode, and the installation process is simple and efficient, which is convenient for quick assembly and later position adjustment.

Triconex 9662-810 Invensys Triconex System Controller Card

Technical Specifications:
  • Type: Controller card for Triconex SIS
  • Compatibility: Designed to work seamlessly with Triconex SIS controllers
  • Input/Output: Supports digital input/output signals for connection to field devices
  • Communication Protocols: May support multiple protocols, depending on system configuration
  • Environmental Conditions: Operates reliably in harsh industrial environments, withstanding high temperatures and electromagnetic interference
  • Certifications: Complies with international safety standards, such as IEC 61508 SIL 3 and ANSI/ISA S84.01

Triconex 9671-810 Digital Input/Output Module

Product Introduction: The Triconex 9671-810 is a digital input/output module designed for use within the Tricon triple modular redundant (TMR) safety control system. It provides a combination of digital input and output channels, enabling it to handle both signal acquisition and control tasks. This module is part of the Triconex family of safety instrumented systems (SIS), known for their high reliability and fault tolerance in critical industrial applications.

Triconex 9750-210 32-Point Current Input Terminal Board

Technical Specifications
  • Electrical Parameters
    • It supports active analog current output with ranges of 4 to 20 mA and 0 to 1 mA, and the accuracy of the 4 to 20 mA range reaches ±1% of full scale.
    • The maximum load for the 4 to 20 mA range is 1200 ohms, while the maximum load for the 0 to 1 mA range is 10 k ohms. It achieves 36 Vpk isolation from RTDs and analog inputs to avoid signal interference.
    • It is equipped with 4 assignable outputs that can be configured for parameters such as phase currents, phase voltages, three - phase average power, and motor load torque as required.
  • Physical Parameters
    • Its overall dimensions are 45 cm × 20 cm × 15 cm, and it weighs 3 kg, which is suitable for installation in standard industrial control cabinets.
    • It adopts a modular structural design that conforms to the installation standards of Triconex series modules, facilitating quick assembly with the system chassis and later disassembly for maintenance.

Triconex 9753-110 Communication Module

Technical Specifications:
  • Processor Configuration: Equipped with three built-in processors for independent handling of communication, program scanning, and I/O output tasks.
  • Voltage: Operates at 24V DC.
  • Current Range: Supports a current range of 100-400A.
  • Weight: The module weighs 2KG.
  • Environmental Resistance: Designed to withstand harsh industrial conditions, including high temperatures and electromagnetic interference.
  • Certifications: Complies with international safety standards, such as IEC 61508 SIL 3 and ANSI/ISA S84.01, ensuring high safety and reliability.

Triconex 9753-1XX

Product Overview The Triconex 9753-1XX is a high-performance safety PLC module designed for industrial safety systems. It is part of the Triconex Trident series, which is renowned for its reliability and fault tolerance in safety-critical applications. The module serves as a crucial component in connecting field devices to the Triconex safety instrumented system (SIS), ensuring secure and reliable signal transmission. Technical Specifications
  • Channels: Supports configurations ranging from 1 to 32 channels.

Triconex 9761-210 Control Module

Product Introduction: The Triconex 9761-210 is a high-performance control module designed for industrial automation and safety systems. It is part of the Triconex family, known for its triple modular redundant (TMR) architecture that provides fault tolerance and high reliability. This module is widely used in critical industrial processes where safety and uninterrupted operation are essential.

Triconex 9771-210 Analog Input Module

Product Introduction: The Triconex 9771-210 is an analog input module designed for use within the Triconex triple modular redundant (TMR) safety control system. It is specifically engineered to receive analog signals from various sensors and convert them into digital signals for processing within the Triconex system. This module is known for its high reliability, fault tolerance, and ability to ensure safe and continuous operation in critical industrial environments.

Triconex 9853-610 Analog Input Terminal Block

Technical Specifications
  • Electrical Parameters
    • It supports multiple analog input ranges, including 0 - 10V, -10V to 10V, 4 - 20mA, and 0 - 20mA, covering the signal requirements of most industrial field sensors.
    • It has a measurement accuracy of ±0.1% and a resolution of 12 bits, and the signal update rate reaches 250ms, which can ensure the accuracy and real-time performance of data collection.
    • It uses a 24VDC power supply, with a power consumption of only 5W, which will not add excessive power burden to the overall safety system.
  • Physical Parameters
    • Its overall dimensions are 110mm × 45mm × 22mm, and its weight is 150g. The compact and lightweight design allows it to be flexibly installed in control cabinets with limited space.
    • It is equipped with screw-type terminals, which can provide firm wiring connections and avoid poor contact caused by vibration in industrial environments.

TRICONEX AI2351 7400210-010

  • Number of Channels: 8
  • Input Range: 4 mA to 20 mA
  • Accuracy: ±0.25%
  • Response Time: Less than 250 ms
  • Power Consumption: 24 VDC, 2.5 A
  • Operating Temperature: - 40°C to +70°C
  • Humidity: 0% to 95% non - condensing
  • Supported Input Signal Types: Voltage (±10V, 0 - 10V) and current (4 - 20mA) (additional information from another source)

Triconex AI3281

Technical Specifications:
  • Input Channels: 32 channels, allowing for the connection of multiple analog sensors.
  • Processor: 32-bit dual-core SIL3-rated safety CPU with a clock speed of 180MHz, ensuring high-speed processing and fault tolerance.
  • Signal Range: Accepts input signals ranging from 0 to 22mA, accommodating a wide variety of sensors and transducers.
  • Accuracy: Offers high-precision data acquisition with a collection accuracy of 0.15%, ensuring accurate monitoring and control.
  • HART Protocol Support: Each channel supports the HART protocol, enabling communication with smart sensors for additional diagnostic and configuration capabilities.
  • TMR Architecture: Utilizes a Triple Modular Redundant (TMR) architecture, providing fault tolerance by using three isolated, parallel control systems. This ensures that the module can continue to operate correctly even in the event of a single-point failure.
  • Diagnostics: Features comprehensive diagnostic capabilities, including channel break and short-circuit detection, enabling quick identification and resolution of issues.