GE 531X302DCIAWG1 Input/Output Module
Technical Specifications:
- Dimensions: 132mm × 105mm × 52mm
- Weight: 800g
- Operating Temperature Range: -10°C to 70°C (extended range: -40°C to +85°C)
- Relative Humidity: ≤90% (non-condensing)
- Storage Temperature: -40°C to 80°C
- Protection Class: IP30
- Mounting Method: Supports 35mm DIN rail mounting
- Communication Interface: Supports data transmission and communication with other devices, potentially including multiple communication protocols and interface standards.
GE 531X301DCCAFG2 Drive Control Board
Technical Specifications:
- High Integration: Combines drive control, data acquisition, and processing functions.
- Real-time Response: Capable of rapid response and high-speed data processing to ensure stable operation of industrial processes.
- Modular Design: Supports customization and expansion with various input/output interfaces and communication protocols.
- Operating Voltage: 24Vdc/120Vac
- Warranty: One year
- Operating Frequency: 50/60Hz
- Sales Range: Domestic and international markets
- Applications: Numerical control machinery, metallurgy, petroleum, and natural gas industries
GE 489-P5-LO-A20 Generator Management Relay
Technical Specifications:
- Phase Current Inputs: 5 A phase CT secondaries
- Control Power Supply:
- LO control power range: 20-60 VDC
- 48-62 VAC at 20-48 Hz
- Analog Output: 4-20 mA
- Frequency Range: 0.00 to 90.00 Hz
- Voltage Parameters:
- Zero-line voltage range: 0 to 25000 V
- Average voltage range: 0.00 to 1.50 times rated voltage
- Power Factor: 0.01 to 1.00 (leading/lagging)
GE 489-P5-HI-A20-T Generator Management Relay
Technical Specifications:
- Phase Current Inputs: 5 A phase CT secondaries
- Control Power Supply:
- AC: 70–265 V (48–62 Hz)
- DC: 90–300 V
- Analog Output: 4–20 mA configurable outputs
- Display: Enhanced LCD for clear status and diagnostic information
- Communication Interface: Supports multiple communication protocols, including RS485 and Modbus, for data exchange and remote monitoring
GE 489-P5-HI-A20 Generator Management Relay
Technical Specifications:
- Phase Current Inputs: 5 A phase CT secondaries
- Control Power Supply:
- AC: 70–265 V (48–62 Hz)
- DC: 90–300 V
- Analog Output: 4–20 mA configurable outputs
- Display: Enhanced LCD for clear status and diagnostic information
- Communication Interface: Supports multiple communication protocols such as RS485 and Modbus for data exchange and remote monitoring
- Operating Temperature: -40 °C to +60 °C
- Storage Temperature: -40 °C to +80 °C
- Enclosure: IP40 (front), IP20 (back)
GE 469-P5-LO-A20-E Motor Management Relay
Technical Specifications:
- Control Power Supply:
- AC: 70–265 V (48–62 Hz)
- DC: 90–300 V
- Phase Current Inputs: 5 A phase CT secondaries
- Analog Output: 4–20 mA configurable outputs
- Digital Inputs: 9 optically isolated inputs for external control signals
- Display: Enhanced 40-character LCD for clear status and diagnostic information
- Operating Temperature: -40 °C to +60 °C
GE 469-P5-HI-A20-E Motor Management Relay
Technical Specifications:
- Control Power Supply:
- AC: 70–265 V (48–62 Hz)
- DC: 90–300 V
- Current Inputs: 5 A phase CT secondaries
- Analog Output: 4–20 mA configurable outputs
- Digital Inputs: 9 optically isolated inputs for external control signals
- Display: Enhanced 40-character LCD for clear status and diagnostic information
- Operating Temperature: -40 °C to +60 °C
GE 469-P5-HI-A20-E SR469-CASE Motor Management Relay
Technical Specifications:
- Control Power Supply:
- AC: 70–265 V (48–62 Hz)
- DC: 90–300 V
- Current Inputs: 5 A phase CT secondaries
- Analog Output: 4 × 0–1 mA or 4–20 mA configurable outputs
- Digital Inputs: 9 optically isolated inputs for external control signals
- Display: Enhanced 40-character LCD for clear status and diagnostic information
- Operating Temperature: -40 °C to +60 °C
GE 469-P1-HI-A20-E Motor Management Relay
Technical Specifications:
- Power Supply: 85–265 V AC/DC
- Power Consumption: <20 W
- Input Signals: Voltage, current, frequency, and switch-state inputs
- Output Contacts: Dry contact outputs for tripping and alarms
- Communication Interfaces: RS485 (Modbus RTU), Ethernet (IEC 61850, DNP3, Ethernet/IP)
- Operating Temperature: -40°C to +85°C
- Storage Temperature: -40°C to +95°C
- Protection Class: IP54 (dust and water-resistant)
- Mounting: Panel-mounted
- Certifications: IEEE C37.118, IEC 60255, UL 508A
GE 369-LO-0-M-0-0-0-E Motor Protection Relay
Technical Specifications:
- Control Power Input: 100-240 VAC (50/60 Hz) or 110-250 VDC
- Current Input: 1 A or 5 A (secondary of current transformers)
- Voltage Input: Not directly applicable (focuses on current-based protection)
- Frequency Range: 45-65 Hz
- Output Contacts: 4 programmable relay outputs (2 for tripping, 2 for alarms)
- Digital Inputs: 2 optically isolated inputs for external control or status monitoring
- Operating Temperature: -20°C to +60°C
GE 369-HI-R-M-0-P1-0-E Motor Management Relay
Technical Specifications:
- Control Power Input: 50-300 VDC or 60-265 VAC
- Current Input: 1 A or 5 A (secondary of current transformers)
- Voltage Input: 50-300 VAC (line-to-line)
- Frequency Range: 45-65 Hz
- Output Contacts: Multiple programmable relay outputs (up to 8) for tripping and alarm functions
- Analog Outputs: 4-20 mA or 0-20 mA programmable outputs for metering or control purposes
- Digital Inputs: 6 optically isolated inputs for external control or status monitoring
- RTD Inputs: 12 channels for temperature monitoring (e.g., stator windings, bearings)
GE 369-HI-R-M-0-0-0-E Motor Management Relay
Technical Specifications:
- Control Power Input: 50-300 VDC or 60-265 VAC
- Input Current: 1 A or 5 A (secondary of current transformers)
- Output Current: Up to 10 A
- Frequency: 50-60 Hz
- Operating Temperature Range: -40°C to +70°C
- Storage Temperature Range: -40°C to +85°C
- Humidity Range: 5% to 95% RH (non-condensing)
- Dimensions: Approximately 200 mm x 151 mm x 106 mm (7.87 inches x 6.14 inches x 3.98 inches)
- Weight: Approximately 4.5 kg (10 pounds)