YOKOGAWA AAI143‑H53

Product Name: 16‑Channel Isolated HART‑capable Analog Input Module for Centum‑VP DCS

Product Description: This is high‑density analog input module of Yokogawa Centum‑VP DCS system, collect 4‑20 mA analog signal from field transmitters, support HART 5/7 digital communication, complete analog‑to‑digital conversion and HART instrument data parsing, transmit data to DCS control node via ESB bus.

Category:
Description

Technical Specifications: 16 input channels, 4‑20 mA DC input signal, support HART protocol, A/D conversion resolution 16‑bit, channel‑to‑system isolation, power supply 24 V DC supplied by node unit, ESB‑bus communication interface.

Functional Features: Wire‑break detection, over‑range input diagnosis, HART burst‑message processing, module‑level redundancy support, per‑channel signal filtering, screw‑type field‑wiring terminals, EMC‑optimized shielding design.

Application Scenarios: Petrochemical plant process‑variable acquisition, oil‑refinery DCS measurement‑signal input, chemical‑factory smart‑transmitter signal collection, power‑plant process monitoring, pulp‑and‑paper industry Centum‑VP system I/O configuration.

Performance Parameters: Basic accuracy ±0.1 % full scale, single‑channel scanning rate minimum 100 ms, operating temperature 0 ℃ ~ +60 ℃, relative humidity 5‑95 % non‑condensing, IP20 protection grade, revision S1 enhanced signal‑filtering performance.

Material Composition: Industrial‑grade flame‑retardant plastic housing, multi‑layer printed circuit board, isolation components, HART demodulation chip, gold‑plated ESB‑bus connector.

Structural Features: Standard node‑unit plug‑in module, front‑side field‑wiring screw terminals, module‑status LED indicator, rear‑edge ESB‑bus back‑plane connector, mechanical locking structure for node chassis.

Working Principle: Field 4‑20 mA analog signal with superimposed HART digital signal enters module channel; analog signal completes isolation and A/D conversion, HART digital signal is demodulated and parsed; converted measurement value and HART instrument diagnostic data are transmitted to DCS control node through ESB bus; receive host command and realize HART instrument parameter access operation.

Installation Requirements: Insert module into corresponding slot of Centum‑VP node unit, lock module fixing mechanism, connect field transmitter shielded cable to front‑side screw terminals, confirm node‑unit 24 V DC power‑supply normal, complete module hardware‑configuration in engineering software.

Usage Notes: Field shielded‑cable shield layer single‑end grounding, HART loop load resistance must satisfy HART specification, do not hot‑plug under non‑redundant power‑on condition, check wire‑break diagnostic alarm in case of abnormal measurement value.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “YOKOGAWA AAI143‑H53”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.