Technical Specifications:
-
Input: J-type thermocouple, −100 °C to +760 °C
-
Output: 4–20 mA HART 7, loop powered 10.5–42 V DC
-
Accuracy: ±0.1 % of span
-
Cold-junction compensation: ±0.5 °C
-
Response: < 0.5 s to 90 % step
-
Common-mode rejection: 25 V
-
Linearization: 16-point PV characterization
-
Housing: 316L stainless steel, dual-compartment (electronics isolated from terminals)
-
Ingress: IP66/IP68
-
Explosion protection: ATEX, IECEx, FM, CSA
-
Process connection: 1/2″ NPT or G1/2
-
Ambient: −40 °C to +85 °C
Features: Sensor-break diagnostics, magnetic local adjust, HART 7 digital trim, moisture-resistant dual compartment.
Applications: Chemical reactors, oil/gas pipelines, steam headers, food pasteurization, pharma sterilization, HVAC critical rooms.
Installation Notes: Use shielded twisted pair, earth ground at one point, annual calibration check, verify seal integrity for IP rating.