ABB CONTRANS T TEU471

Product Brief

DIN rail mounted two-wire isolation temperature transmitter designed to convert thermocouple and RTD resistance temperature sensor signals into standardized 4–20 mA analog current output signal, providing full galvanic isolation between sensor field side and control system side for industrial process temperature measurement and DCS/PLC signal transmission.
Category:
Description

Technical & Performance Specifications

  • Supported Input Sensor Types: Pt100/Pt1000 RTD (2/3/4-wire), all standard thermocouple types (K, J, T, E, N, S, R, B)
  • Input Measurement Resolution: 0.01°C for RTD; 0.1°C for thermocouple
  • Output Standard Signal: 4 mA ~ 20 mA two-wire loop powered analog current
  • Galvanic Isolation Voltage: 2500 V AC between input, output and power circuits
  • Measurement Basic Accuracy: ≤±0.1% full scale
  • Temperature Drift Coefficient: ≤0.005% FS / °C
  • Loop Supply Voltage Range: 12 V DC ~ 30 V DC two-wire loop power supply
  • Max Loop Load Resistance: 500 Ω at 24 V DC supply
  • Response Time (t90): ≤300 ms
  • Operating Ambient Temperature: -40°C ~ +70°C
  • Protection Class: IP20 cabinet installation
  • Mounting Standard: 35 mm EN60715 standard DIN rail
  • Unit Dimensions: W 17.5 mm × H 100 mm × D 115 mm
  • Unit Weight: 85 g
  • Certifications: CE, UL, ATEX IECEx Zone 0/1/20 intrinsic safety approval

Function Features

  1. Universal multi-sensor input auto-recognition function eliminates manual hardware jumpers during commissioning
  2. 2500 V AC three-way full galvanic isolation blocks ground loop interference between field sensors and control room systems
  3. Built-in cold junction compensation circuit for thermocouple measurement to eliminate cold junction temperature error
  4. Configurable via ABB PC programming software or handheld HART configuration device for temperature range scaling
  5. Overvoltage, reverse power, short-circuit output multi-layer circuit protection
  6. Compact 17.5 mm narrow width design maximizes cabinet rack channel density

Working Principle

Field temperature sensor analog signal enters the isolated input front-end circuit; internal high-precision ADC converts resistance/millivolt sensor signals into digital temperature values. Onboard microcontroller executes linearization correction for thermocouple/RTD non-linear characteristics, maps user-configured temperature measurement range to standard 4–20 mA current loop signal. High-frequency isolation transformer separates field sensor circuit and control side loop circuit to eliminate ground potential difference interference, standardized current signal transmits to DCS/PLC analog input modules via two-wire loop wiring.

Material & Structural Composition

  • Housing: Flame-retardant gray polycarbonate DIN rail enclosure with integrated ventilation slots
  • Main PCB: Multi-layer FR4 industrial circuit board with reinforced isolation transformer barrier
  • Terminal Blocks: Spring-cage quick-disconnect copper terminals supporting 0.5–2.5 mm² wire
  • Internal Isolation Component: Epoxy encapsulated high withstand voltage isolation transformer

Advantage Highlights

  1. ATEX intrinsic safety certification supports direct installation inside hazardous chemical, oil & gas field measurement cabinets
  2. Three-way high voltage galvanic isolation completely eliminates industrial site ground loop signal noise
  3. Universal sensor compatibility reduces spare part inventory types for factory maintenance stock
  4. Narrow 17.5 mm body greatly improves cabinet channel layout density
  5. Two-wire loop powered design simplifies field wiring layout with only two signal cables required
  6. Ultra-low temperature drift maintains stable measurement precision under wide ambient temperature fluctuation

Applicable Industries

Chemical process plants, oil & gas refineries, power generation boilers, food & beverage thermal processing, pharmaceutical manufacturing furnaces, water treatment temperature monitoring

Installation Requirements

  • Mounting Standard: Vertical 35 mm DIN rail mounting inside IP54+ sealed control cabinet
  • Vertical Clearance: Minimum 20 mm top and bottom air gap for passive heat dissipation
  • Sensor Wiring: Shielded twisted pair instrument cable for thermocouple/RTD input; matching thermocouple extension wire mandatory for thermocouple sensors
  • Loop Wiring: Standard two-core shielded cable for 4–20 mA output loop, single-point ground shielding at control room side

Operation & Maintenance Notes

  1. Re-calibration verification required every 24 months per ISO process control standards
  2. Thermocouple extension wire must match thermocouple alloy type to avoid cold junction compensation error
  3. Do not install TEU471 adjacent to high-power variable frequency drives without minimum 15 cm separation distance
  4. Spring-cage terminals must fully clamp wire copper core; frayed wire strands will cause unstable measurement signal
  5. Intrinsic safety wiring specifications must strictly follow ATEX zone wiring regulations for hazardous area deployment

9. KEBA CP253W

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ABB CONTRANS T TEU471”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.