Bently Nevada 3500/15 106M1081-01 Universal AC Power Input Module (PIM)

Technical Specifications
  • Input Voltage: 85–264 Vac rms, 47–63 Hz
  • Peak Voltage Withstand: 120–373 Vac pk
  • Maximum Rack Current: 2.8 A rms @ 240 Vac
  • Inrush Current: <25 A peak, <5 ms
  • Filtering: Differential-mode choke plus metal-oxide varistor
  • Isolation: Input-to-earth 1.5 kVac, input-to-output 500 Vdc
  • Temperature Range: –30 °C to +65 °C operational, –40 °C to +85 °C storage
  • Dimensions: 120.7 mm × 25.4 mm × 114.3 mm (H × W × D)
  • Weight: 0.34 kg (0.75 lb)
  • Connector: IEC C14 inlet, crimp fork terminals for rack back-plane
  • Agency Marks: CE, UL 508, ATEX, IECEx, CSA, TR CU, RoHS, REACH
Category:
Description
Functional Highlights
  • Universal Input: Accepts any mains from 85 Vac to 264 Vac without jumper selection.
  • Hot-Swap Design: Slide-in module with captive screws; replacement <30 s while rack remains powered when redundant supply is present.
  • Redundancy Ready: Two PIMs can be installed in parallel with automatic load-sharing and fail-over.
  • Surge Immunity: Integrated MOV and gas tube protect against 4 kV line-to-earth transients per IEC 61000-4-5.
  • Low Leakage: <0.5 mA earth-leakage current meets medical-grade safety requirements.
  • System Integration: Front-panel LEDs and relay contacts report status to 3500/20 Rack Interface Module for System 1 software display.
Application Scenarios
  • Steam-, gas- and hydro-turbine generator vibration and thrust protection
  • Centrifugal and reciprocating compressors in LNG, olefins and refinery process trains
  • High-pressure boiler feed-water pumps in coal-fired and combined-cycle plants
  • Large motors, fans and gearboxes in steel, pulp & paper, mining and cement mills
  • Offshore platform critical drives and sub-sea pump motor monitoring
  • Nuclear reactor coolant pump vibration and speed trending
Installation Notes
Insert PIM directly behind its mating 3500/15 power supply; torque captive screws to 0.8 N·m; verify input voltage is within 85–264 Vac before energizing; bond earth terminal to rack earth bus with 2.5 mm² conductor; maintain 50 mm clearance above and below for cooling; operate only in environments that do not exceed IP 20 ingress protection.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Bently Nevada 3500/15 106M1081-01 Universal AC Power Input Module (PIM)”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.