Triconex 3636T

Technical Specifications:
  • Type: Relay output module
  • Channels: Multiple relay output channels (specific number may vary based on configuration)
  • Output Configuration: Normally closed (NC) contacts, non-common
  • Voltage Rating: Compatible with various voltage levels, depending on application requirements
  • Environmental Conditions: Designed to operate in harsh industrial environments with appropriate temperature and humidity ranges
  • Mechanical Design: Rugged and compact for easy installation in standard Triconex racks
  • Certifications: Meets international safety standards, including IEC 61508 SIL 3 certification for safety integrity level

Triconex 3664 Digital Output Module

Product Overview The Triconex 3664 is a high-reliability digital output module designed for safety-critical applications in industrial automation. It is part of the Triconex TMR (Triple Modular Redundant) architecture, ensuring fault tolerance and high system availability. The module is used to control field devices such as solenoid valves, relays, and actuators, playing a key role in safety instrumented systems (SIS) for process interlock and emergency shutdown (ESD) control applications.

Triconex 3664 Dual Digital Output Module

Technical Specifications
  • Electrical Parameters
    • It is equipped with 32 commoned digital output channels, the nominal output voltage is 24 VDC, and the adaptive voltage range is 16 - 30 VDC.
    • Each output point has a current rating of 2 A, and can withstand a 10 A surge current for 10 milliseconds. The typical voltage drop of the module is less than 1.5 VDC, and the maximum load leakage current is 2 mA.
    • The minimum isolation voltage between points reaches 1500 VDC, which effectively isolates electrical interference between different channels, and the overall power consumption of the module is less than 10 watts.
  • Physical and Environmental Parameters
    • The module weighs 4 kg and has dimensions of 120 mm x 80 mm x 30 mm. It adopts a modular structure design to facilitate installation in standard control cabinets.
    • The operating temperature range is -40°C to 70°C, and it can work normally in an environment with 0 - 95% non-condensing humidity. The enclosure has an IP66 protection rating, which can effectively prevent dust and water from entering and adapt to harsh on-site industrial conditions.

Triconex 3700A Triple Modular Redundancy Analog Input Module

Technical Specifications
    • Electrical Parameters
      • It is configured with 32 differential input points, and each channel can be configured to support 4 - 20 mA, 0 - 20 mA, or 0 - 5 V DC signals.
      • It is equipped with a 16 - bit ADC, and the typical accuracy for the 4 - 20 mA signal is ±0.1% of full scale. The minimum input resistance is 30 MΩ (DC), and the typical power - off resistance is 30 kΩ (DC).
      • It obtains a +5 V DC operating voltage from the Tricon backplane, with a typical power consumption of about 2 W, and has 1500 V AC/DC isolation to enhance noise immunity.
    • Response and Detection Parameters
      • The update rate is 10 ms per channel, enabling fast response to safety system requirements, and the response time is less than 500 μs.
      • It is capable of open and short - circuit detection for each channel, and can conduct comprehensive hardware and software fault detection through self - testing.

Triconex 3703E

Technical Specifications:
  • Communication Protocols: Supports Modbus, Ethernet/IP, DeviceNet, and ControlNet protocols.
  • Baud Rate: Ranges from 9600 bps to 115200 bps, ensuring flexible data transfer rates.
  • Connection Methods: Equipped with RS-232, RS-422, RS-485, and RJ-45 interfaces for versatile connectivity.
  • Operating Temperature: Functions reliably within a temperature range of -40°C to 70°C, suitable for harsh industrial environments.
  • Dimensions: Compact design with dimensions of 3U height x 1HP width, facilitating easy installation.
  • Weight: Weighs approximately 1.0 kg, making it lightweight and manageable.

Triconex 3704E

Technical Specifications:
  • Voltage Range: 0-5V or 0-10V (selectable via TriStation software).
  • Number of Input Points: 64 commoned inputs.
  • Input Update Rate: 75 milliseconds.
  • Resolution: 12 bits.
  • Accuracy: Less than 0.25% of full-scale range (FSR) from 0°C to 60°C.
  • Power-Off Resistance: 30 kΩ (DC), typical.
  • Leg-to-Leg Isolation: 200 kΩ, typical.
  • Input Overrange Protection: 150 VDC/115 VAC continuous.
  • Diagnostic Indicators: PASS, FAULT, ACTIVE.
  • Color Code: Copper.

Triconex 3706A

Technical Specifications:
  • Input Type: Thermocouple analog input
  • Number of Channels: Multiple independent channels (specific configuration may vary based on model)
  • Voltage Range: Supports a range of voltage inputs, typically 0-5Vdc or other standard thermocouple voltage ranges
  • Accuracy: High precision with minimal error margins, ensuring accurate signal measurement
  • Isolation: Each channel is electrically isolated to prevent interference and enhance safety
  • Environmental Conditions: Designed to operate in harsh industrial environments with appropriate temperature and humidity ranges
  • Mechanical Design: Compact and rugged for easy installation in standard Triconex racks
  • Certifications: Meets international safety standards, including IEC 61508 SIL 3 certification for safety integrity level

Triconex 3708E

Technical Specifications:
  • Input Type: Thermocouple analog input
  • Number of Channels: Multiple independent channels (specific configuration may vary based on model)
  • Voltage Range: Supports standard thermocouple voltage ranges, typically 0-5Vdc or other ranges depending on the thermocouple type
  • Accuracy: High precision with minimal error margins, ensuring accurate temperature measurement
  • Isolation: Each channel is electrically isolated to prevent interference and enhance safety
  • Environmental Conditions: Designed to operate in harsh industrial environments with appropriate temperature and humidity ranges
  • Mechanical Design: Compact and rugged for easy installation in standard Triconex racks
  • Certifications: Meets international safety standards, including IEC 61508 SIL 3 certification for safety integrity level

Triconex 3720

Technical Specifications:
  • Voltage Range: Supports multiple voltage ranges, including 0-5VDC, ±5VDC, and 0-10VDC (selectable via software).
  • Input Points: 64 single-ended inputs.
  • Input Update Rate: 10 milliseconds for rapid data acquisition.
  • Resolution: 12-bit or 14-bit programmable for high-precision measurements.
  • Accuracy: Less than 0.15% of full-scale range (FSR) from 0°C to 60°C, ensuring precise signal conversion.
  • Isolation: Each input channel is electrically isolated with a typical leg-to-leg isolation resistance of 420 kΩ, preventing interference and enhancing safety.

Triconex 3721

Technical Specifications:
  • Input Type:
    • Analog Input: Supports 32 differential, DC-coupled channels for monitoring various types of analog signals, such as voltage or current.
    • Digital Input: Provides 16 channels for monitoring digital signals (specific configurations may vary based on model and application).
  • Voltage Range: 0-5VDC or -5 to +5VDC (differential), with additional support for other ranges depending on the configuration.
  • Input Update Rate: 10 milliseconds for rapid data acquisition.
  • Resolution: 12-bit or 14-bit programmable for high-precision measurements.
  • Accuracy: Less than 0.15% of full-scale range (FSR) from 0°C to 60°C, ensuring precise signal conversion.

Triconex 3721

Technical Specifications:
  • Input Type: 32 differential, DC-coupled channels for analog input.
  • Voltage Range: 0-5 VDC or -5 to +5 VDC.
  • Input Update Rate: 10 milliseconds for rapid data acquisition.
  • Resolution: 12-bit or 14-bit programmable for high-precision measurements.
  • Accuracy: Less than 0.15% of full-scale range (FSR) from 0°C to 60°C, ensuring precise signal conversion.
  • Isolation: Each channel is electrically isolated with a typical leg-to-leg isolation resistance of 420 kΩ, preventing interference and enhancing safety.
  • Input Overrange Protection: Continuous protection up to 150 VDC/115 VAC to safeguard against voltage surges.
  • Diagnostic Indicators: PASS, FAULT, ACTIVE, and FIELD indicators for comprehensive system monitoring and troubleshooting.
  • Color Code: Yellow for easy identification.
  • Environmental Conditions: Designed to operate in harsh industrial environments, withstanding extreme temperatures, shock, and vibration.

Triconex 3721C

Technical Specifications:
  • Input Type: Supports multiple input types, including voltage, current, thermocouple, and RTD (Resistance Temperature Detector).
  • Voltage Range: 0 to 5 VDC or -5 to +5 VDC, with an additional ±6% tolerance.
  • Input Points: 32 differential, DC-coupled channels.
  • Input Update Rate: 10 milliseconds for rapid data acquisition.
  • Resolution: 12-bit or 14-bit programmable for high-precision measurements.
  • Accuracy: Less than 0.15% of full-scale range (FSR) from 0°C to 60°C, ensuring precise signal conversion.
  • Common-Mode Rejection: -85 dB (DC–100 Hz) to minimize interference from external sources.
  • Input Overrange Protection: Continuous protection up to 150 VDC/115 VAC to safeguard against voltage surges.
  • Weight: 1.36 kilograms for easy installation and handling.