Triconex DI2301 Digital Input Module

Product Introduction: The Triconex DI2301 is a digital input module designed for use within Triconex safety instrumented systems (SIS). It is responsible for receiving digital input signals from field devices and transmitting them to the control system for further processing. This module plays a crucial role in ensuring the accurate and reliable monitoring of safety-critical processes.

Triconex DI3201 Digital Input Module

Technical Specifications
  • Processor: 32-bit dual-core safety CPU, 180 MHz clock speed
  • Channels: 32 digital input channels per module
  • Redundancy: Triple Modular Redundant (TMR) architecture for fault tolerance
  • Input Signal Range: Compatible with standard digital voltage levels (e.g., 24 V DC)
  • SOE Resolution: Supports Sequence of Events (SOE) with 1 ms timestamp accuracy
  • Communication: Integrated into Triconex TMR systems via backplane or fieldbus interfaces
  • Environmental: Operates in temperatures from -40°C to 70°C; IP20 protection rating
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2

Triconex DI3301 Digital Input Module

Technical Specifications
  • Input Channels: 32 independent digital input channels, each with isolated electronics for fault tolerance.
  • Input Voltage Range: 18–32 VDC (typically 24 VDC).
  • Input Current: Maximum 6 mA per channel.
  • Input Types: Supports dry contacts (e.g., limit switches) and wet contacts (e.g., relay outputs).
  • Channel Isolation: Each input channel is isolated from the system bus to prevent interference.
  • Redundancy: Triple Modular Redundant (TMR) architecture ensures continuous operation even if one channel fails.
  • Response Time: ≤ 5 ms (including filtering).
  • Diagnostics: Line monitoring, open-circuit detection, short-circuit detection, and self-diagnostics.
  • Operating Temperature: -20°C to +60°C.
  • Storage Temperature: -40°C to +85°C.
  • Humidity Range: 5%–95% RH (non-condensing).
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2.

TRICONEX DI3301 Digital Input Module

Technical Specifications
  • Input Channels: 32 independent digital input channels
  • Input Voltage Range: 18–32 VDC (typical 24 VDC)
  • Input Current: ≤6 mA per channel
  • Input Types: Dry contact or wet contact signals
  • Channel Isolation: Each input channel is isolated from the system bus
  • Redundancy Design: TMR (Triple Modular Redundant) input paths per channel
  • Response Time: ≤5 ms (including filtering)
  • Diagnostic Functions: Line monitoring, open-circuit detection, short-circuit detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Humidity Range: 5%–95% RH (non-condensing)
  • Weight: 1.42 kg
  • Mounting: Mechanically locked to prevent misinstallation
  • Certifications: SIL 3 (IEC 61508), TÜV Rheinland-certified

Triconex DO 3626X Digital Output Module

Technical Specifications:
  • Channels: Multiple digital output channels (specific count varies by configuration).
  • Output Type: Switch-type (ON/OFF) for discrete control.
  • Output Current: Supports up to 2A per channel (actual value may vary based on configuration).
  • Load Voltage: Compatible with 24V DC systems (other voltages may be supported depending on model).
  • Response Time: ≤2ms for rapid signal conversion.
  • Power Consumption: Optimized for low energy use, typically ≤5W.
  • Operating Temperature: -20°C to +70°C (industrial-grade).
  • Dimensions: Compact design for space-efficient installation (e.g., 160mm × 100mm × 25mm).
  • Weight: Approximately 2kg.
  • Certifications: Compliant with IEC 61508 (SIL 3), TÜV, and other industrial safety standards.

TRICONEX DO3201 Digital Output Module

Technical Specifications
  • Processor: 32-bit dual-core SIL3-rated safety CPU, 180 MHz clock speed
  • Channels: 32 digital output channels per module
  • Architecture: Triple Modular Redundant (TMR) for fault tolerance
  • Output Current: Single-channel maximum 2 A
  • Output Signal Range: Supports standard industrial voltage levels (e.g., 24 V DC)
  • SOE Resolution: Supports Sequence of Events (SOE) with 1 ms timestamp accuracy
  • Diagnostics: Real-time monitoring of channel status, including open-circuit, short-circuit, and overload fault detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2

TRICONEX DO3401 Digital Output Module

Technical Specifications
  • Output Channels: 32 digital output channels
  • Output Type: 24 VDC, low-level effective (Sink-type output)
  • Output Structure: Transistor output (NPN or PNP, depending on version)
  • Output Capacity: Maximum 0.5 A per channel
  • Output Voltage Range: 18–32 VDC (24 VDC recommended)
  • Channel Isolation: Each channel is optically isolated from the system bus
  • Response Time: ≤ 5 ms (channel delay)
  • Short-Circuit Protection: Channel-level short-circuit and overcurrent protection
  • Redundancy: Operates with Triconex's triple modular redundant (TMR) architecture for fault tolerance
  • Status Monitoring: Supports per-channel status diagnostics, failure monitoring, and LED status indicators
  • Module Identification: Supports automatic identification and configuration, with channel addresses assigned by the controller

Triconex DO3401S2 Digital Output Module

Product Introduction: The Triconex DO3401S2 is a high-performance digital output module designed for safety-critical applications in industrial automation. It is part of the Triconex family of safety instrumented systems (SIS), known for their robustness, reliability, and compliance with stringent safety standards. The DO3401S2 module provides multiple digital output channels to control external devices such as valves, relays, and solenoids, ensuring safe and efficient operation in hazardous environments.

TRICONEX DO3625A Digital Output Module

Technical Specifications
  • Channels: 8 digital output channels
  • Output Type: Switch-type outputs
  • Output Current: 2 A per channel
  • Load Voltage: 250 V AC/DC
  • Response Time: ≤ 2 ms
  • Power Consumption: ≤ 5 W
  • Dimensions: 160 mm x 100 mm x 25 mm
  • Redundancy: Triple Modular Redundant (TMR) design for enhanced fault tolerance
  • Safety Certification: Compliant with SIL 3 safety integrity level requirements

TRICONEX DO3626X Digital Output Module

Technical Specifications
  • Output Channels: Multiple digital output channels (exact count varies by configuration).
  • Output Voltage: 24 V DC (standard industrial voltage).
  • Output Current: Supports a range of current levels to drive various loads (e.g., 100–400 A in some configurations).
  • Redundancy: Triple Modular Redundant (TMR) architecture ensures fault tolerance, allowing continuous operation even if one channel fails.
  • Response Time: Fast response time for real-time control applications (≤ 5 ms in typical configurations).
  • Operating Temperature: -20°C to +60°C (industrial-grade temperature range).
  • Storage Temperature: -40°C to +85°C.
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2 and other international standards.

TRICONEX DO9662-810 Digital Output Module

Technical Specifications
  • Output Channels: 16 digital output channels
  • Output Voltage: 24 VDC
  • Output Current: Supports low-level effective (sink-type) outputs with a maximum of 0.5 A per channel
  • Channel Isolation: Each channel is optically isolated from the system bus to prevent interference and ensure fault tolerance
  • Response Time: Fast response time for real-time control applications (≤ 5 ms)
  • Redundancy: Operates within Triconex's triple modular redundant (TMR) architecture for enhanced fault tolerance
  • Status Monitoring: Supports per-channel diagnostics, including open-circuit and short-circuit detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2 and other international standards

TRICONEX EM2281 Safety Controller Module

Technical Specifications
  • Redundancy Architecture: Triple Modular Redundant (TMR) for enhanced fault tolerance.
  • Input/Output Channels: Supports a variety of I/O configurations, including digital and analog inputs/outputs, depending on the specific model and configuration.
  • Communication Protocols: Modbus RTU/TCP, HART, and other industrial protocols for seamless integration with DCS and SCADA systems.
  • Input Voltage: 24 V DC.
  • Power Consumption: Approximately 20 W.
  • Operating Temperature Range: 0°C to +60°C.
  • Storage Temperature Range: -40°C to +85°C.
  • Protection Class: IP20.
  • Programming Software: TriStation 1131 for configuration and programming.
  • Certifications: Compliant with IEC 61508 SIL 3, FM, ATEX, and other international safety standards.