TRICONEX 9563-810 Digital Input Termination Panel

Technical Specifications:

  • Type: Typically serves as an interface or communication module within the Tricon system.
  • Communication Protocols: Supports industry-standard protocols to ensure compatibility with various control systems and devices.
  • Power Supply: Operates within specified voltage ranges suitable for industrial environments.
  • Environmental Endurance: Designed to withstand harsh conditions including wide temperature ranges, humidity, and exposure to dust.
  • Certifications: Certified for use in Safety Instrumented Systems (SIS) up to Safety Integrity Level 3 (SIL 3), ensuring compliance with stringent safety standards.

Triconex 9573-110F Analog Input Communication Module

Technical Specifications
  • Signal Processing Parameters
    • It can convert small signals based on high common - mode voltage into single - ended signals relative to the system chassis ground, which effectively solves the interference problem of high common - mode voltage on signal transmission.
    • The built - in isolation amplifier can amplify weak analog input signals. The signal filtering function can filter out external noise, and the measurement resolution and accuracy of analog signals are significantly improved after processing.
    • It supports 8 PI points and 16 PTI points, which can meet the collection and processing needs of multiple groups of analog signals at the same time.
  • Physical Parameters
    • It adopts a standard industrial control card design, which is consistent with the installation size of Triconex series module slots. It can be directly inserted into the dedicated position of the Triconex system chassis for installation.
    • The module uses a hard metal shell, which has good physical protection performance. The wiring interface adopts a standard terminal design, which facilitates firm connection with field sensors and internal system lines.

Triconex 9662-610 Standard Termination Panel

Technical Specifications
  • Electrical Parameters
    • It adopts 24 VDC termination option and has an input voltage range of 0 to 55 VDC, which can adapt to the voltage requirements of different field digital output devices.
    • The long - term drift is less than 0.3%, and the frequency range covers 14 to 60 kHz, ensuring the stability of signal transmission.
    • The maximum power consumption of the panel is 10 W, which will not cause excessive power load to the overall safety system during long - term operation.
  • Physical Parameters
    • Its overall dimensions are 12.7 cm × 12.7 cm × 5.1 cm, and the weight is 0.3 kg. The compact size allows it to be installed in control cabinets with limited space.
    • It adopts DIN rail installation mode, and the installation process is simple and efficient, which is convenient for quick assembly and later position adjustment.

Triconex 9750-210 32-Point Current Input Terminal Board

Technical Specifications
  • Electrical Parameters
    • It supports active analog current output with ranges of 4 to 20 mA and 0 to 1 mA, and the accuracy of the 4 to 20 mA range reaches ±1% of full scale.
    • The maximum load for the 4 to 20 mA range is 1200 ohms, while the maximum load for the 0 to 1 mA range is 10 k ohms. It achieves 36 Vpk isolation from RTDs and analog inputs to avoid signal interference.
    • It is equipped with 4 assignable outputs that can be configured for parameters such as phase currents, phase voltages, three - phase average power, and motor load torque as required.
  • Physical Parameters
    • Its overall dimensions are 45 cm × 20 cm × 15 cm, and it weighs 3 kg, which is suitable for installation in standard industrial control cabinets.
    • It adopts a modular structural design that conforms to the installation standards of Triconex series modules, facilitating quick assembly with the system chassis and later disassembly for maintenance.

Triconex 9853-610 Analog Input Terminal Block

Technical Specifications
  • Electrical Parameters
    • It supports multiple analog input ranges, including 0 - 10V, -10V to 10V, 4 - 20mA, and 0 - 20mA, covering the signal requirements of most industrial field sensors.
    • It has a measurement accuracy of ±0.1% and a resolution of 12 bits, and the signal update rate reaches 250ms, which can ensure the accuracy and real-time performance of data collection.
    • It uses a 24VDC power supply, with a power consumption of only 5W, which will not add excessive power burden to the overall safety system.
  • Physical Parameters
    • Its overall dimensions are 110mm × 45mm × 22mm, and its weight is 150g. The compact and lightweight design allows it to be flexibly installed in control cabinets with limited space.
    • It is equipped with screw-type terminals, which can provide firm wiring connections and avoid poor contact caused by vibration in industrial environments.

TRICONEX AI2351 7400210-010

  • Number of Channels: 8
  • Input Range: 4 mA to 20 mA
  • Accuracy: ±0.25%
  • Response Time: Less than 250 ms
  • Power Consumption: 24 VDC, 2.5 A
  • Operating Temperature: - 40°C to +70°C
  • Humidity: 0% to 95% non - condensing
  • Supported Input Signal Types: Voltage (±10V, 0 - 10V) and current (4 - 20mA) (additional information from another source)

Triconex AIH 3723X

Technical Specifications:
  • Communication Interfaces: RS-485, Ethernet
  • Data Transmission Rate: Up to 10 Mbps
  • Supported Protocols: Modbus, Profibus, HART, and other industrial communication protocols
  • Isolation: Provides isolation between input/output, power supplies, and racks to enhance safety and prevent interference
  • Protection Rating: IP67, ensuring resistance to dust and water ingress
  • Dimensions: 130 mm x 110 mm x 22 mm
  • Weight: 0.5 kg
  • Material: Aluminum alloy
  • Operating Temperature Range: -40°C to +70°C
  • Storage Temperature Range: -55°C to +85°C

Triconex AO3481 Analog Output Module

Technical Specifications:
  • Channel Count: Typically offers multiple channels (the exact number should be confirmed from the official documentation) for connecting various analog output devices.
  • Signal Range: Supports standard analog signal ranges, including 4-20mA and possibly voltage ranges like 0-10V, ensuring compatibility with a wide array of field instruments.
  • Resolution: High-resolution outputs that ensure precise control of connected devices, contributing to accurate process management.
  • Redundancy: Designed with redundancy options to enhance system reliability and availability, critical for safety applications.

TRICONEX CIM3211S2 Safety Interface Module

Technical Specifications
  • Processors: Multiple 333 MHz CPUs for parallel processing.
  • Memory: 64 MB RAM and 256 MB Flash for complex logic operations and data storage.
  • Digital I/O: 32 channels, configurable as inputs or outputs to adapt to diverse field signal requirements.
  • Analog I/O: 16 channels supporting high/low-state digital outputs and compatibility with various sensor signals.
  • Communication Protocols: RS-232, RS-485, Ethernet for seamless integration with third-party devices (e.g., PLCs, DCS).
  • Fieldbus Support: PROFIBUS DP, Modbus RTU, DeviceNet for simplified system architecture.
  • Redundancy: Dual-channel redundant structure with automatic main/backup channel switching to ensure uninterrupted operation during single-point failures.

TRICONEX CM3201 – Communication Module for Safety-Critical Systems

Technical Specifications:

  • Type: Communication Module
  • System Compatibility: Designed to work within the Tricon system architecture, supporting seamless integration with other Tricon components.
  • Communication Protocols: Supports various industry-standard communication protocols, facilitating connectivity with Distributed Control Systems (DCS), Supervisory Control and Data Acquisition (SCADA) systems, and other plant networks.

TRICONEX DI3301 Digital Input Module

Technical Specifications
  • Input Channels: 32 independent digital input channels
  • Input Voltage Range: 18–32 VDC (typical 24 VDC)
  • Input Current: ≤6 mA per channel
  • Input Types: Dry contact or wet contact signals
  • Channel Isolation: Each input channel is isolated from the system bus
  • Redundancy Design: TMR (Triple Modular Redundant) input paths per channel
  • Response Time: ≤5 ms (including filtering)
  • Diagnostic Functions: Line monitoring, open-circuit detection, short-circuit detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Humidity Range: 5%–95% RH (non-condensing)
  • Weight: 1.42 kg
  • Mounting: Mechanically locked to prevent misinstallation
  • Certifications: SIL 3 (IEC 61508), TÜV Rheinland-certified

Triconex DO 3626X Digital Output Module

Technical Specifications:
  • Channels: Multiple digital output channels (specific count varies by configuration).
  • Output Type: Switch-type (ON/OFF) for discrete control.
  • Output Current: Supports up to 2A per channel (actual value may vary based on configuration).
  • Load Voltage: Compatible with 24V DC systems (other voltages may be supported depending on model).
  • Response Time: ≤2ms for rapid signal conversion.
  • Power Consumption: Optimized for low energy use, typically ≤5W.
  • Operating Temperature: -20°C to +70°C (industrial-grade).
  • Dimensions: Compact design for space-efficient installation (e.g., 160mm × 100mm × 25mm).
  • Weight: Approximately 2kg.
  • Certifications: Compliant with IEC 61508 (SIL 3), TÜV, and other industrial safety standards.