Structural Characteristics
- Enclosure material: Flame-retardant polycarbonate industrial housing
- Form factor: Slim vertical DIN rail compact unit
- Terminal zoning: Separate thermocouple/RTD sensor input terminal bank, relay output terminal bank, 24 V DC power terminal block
- Front panel interface: 4 independent LED digital temperature displays, channel status alarm LEDs, tactile parameter adjustment buttons
- Dimensions: 112 mm (H) × 35 mm (W) × 108 mm (D)
- Net weight: 0.59 kg
Technical Specifications
- Channel Configuration: 4 independent isolated temperature measurement channels
- Temperature Sensor Input Compatibility: Type J, K, T, E thermocouples; Pt100 RTD 3-wire sensors
- Measurement Temperature Range: -200 °C to +1372 °C sensor input range (sensor type dependent)
- Control Output Types Per Channel: Form A mechanical relay output (5 A resistive load rating)
- Control Algorithm: PID closed-loop temperature regulation + independent high/low temperature limit safety trip
- Resolution: 0.1 °C display and control resolution
- Power Supply Input: 24 V DC control power, 22 V DC to 28 V DC operating range
- Isolation Rating: 1500 V DC galvanic isolation between each measurement channel
- Operating Temperature Range: 0 °C to +50 °C ambient cabinet temperature
- Safety Compliance: UL 61800-5-2, FM Approved limit safety device, CE, RoHS
Functional Features
- Four fully galvanically isolated temperature measurement channels eliminating cross-channel noise interference
- Independent user-configurable high-limit and low-limit safety trip thresholds per thermal zone
- PID auto-tune routine for automatic proportional, integral, derivative gain parameter calculation
- Latching alarm relay output for critical over-temperature fault conditions with manual reset requirement
- Sensor break detection logic triggering fault alarm upon open thermocouple/RTD wiring failure
- Front-panel digital display independent for each channel showing real-time process temperature
- Non-volatile flash memory retaining all setpoint, limit, and PID configuration parameters through power loss
Working Principle
Each isolated measurement channel samples resistance/voltage signals from connected thermocouple or RTD temperature sensors at fixed 100 ms scan intervals. Internal signal conditioning circuit converts raw sensor signal to calibrated temperature value, which is displayed on dedicated channel front-panel LED readout. Compares measured process temperature against user-programmed PID setpoint and safety limit thresholds. PID control algorithm calculates required heating/cooling relay output duty cycle to maintain target setpoint temperature. If measured temperature exceeds programmed high/low safety limit value, latching alarm relay activates to cut heating power circuits until manual operator reset is performed. Sensor break detection continuously monitors input circuit impedance to flag open wiring faults and trigger safety shutdown logic.
Advantage Highlights
- Four isolated temperature channels within single 35 mm slim DIN rail unit reduces cabinet hardware count
- FM safety certified limit function meets industrial process over-temperature safety standard requirements
- Independent latching safety relays provide hardwired thermal cutout protection without external safety modules
- Universal thermocouple and RTD sensor input compatibility for diverse industrial heating applications
- Auto-tune PID eliminates manual gain calibration setup time for new thermal process systems
Applicable Industries
Plastic injection molding barrel heating, packaging heat seal equipment, semiconductor wafer processing ovens, composite curing ovens, food processing thermal sterilization machinery, laboratory thermal test chambers
Installation Requirements
- Mount vertically on standard 35 mm DIN rail inside IP20 minimum rated control cabinet
- Maintain minimum 15 mm horizontal clearance between adjacent DIN rail devices for cross-ventilation
- Run shielded twisted-pair sensor cable for all thermocouple/RTD wiring, separate from high-current AC power wiring
- Connect regulated 24 V DC power supply with minimum 1.5 A continuous output capacity
- Wire safety limit relay outputs in series with heating element power contactor control circuit for fail-safe operation
Usage Precautions
- Do not install unit in cabinet environments with airborne oil mist or chemical solvent vapor exposure
- Verify cold junction compensation calibration annually for thermocouple measurement accuracy
- Replace mechanical control relays after 100,000 switching cycles to prevent contact degradation
- Avoid routing sensor wiring parallel to AC motor power cables to suppress inductive measurement noise
- Disable unused measurement channels via front panel configuration to reduce background signal processing load
Reviews