Parker AR-04AE-13574

Product Overview

AR-04AE-13574 is a rack-mounted AC input single-axis digital servo drive designed for Parker permanent magnet brushless servo motors, linear motors and direct drive torque motors. The AR rack form factor enables multi-axis dense stacking in industrial control cabinets for high-precision synchronous motion automation equipment.
Category:
Description

Technical Specifications

  1. Input Power: Single-phase 120 / 240 VAC 50/60 Hz auto-switching mains supply
  2. Continuous RMS Output Current: 4 A
  3. Peak Overload Current: 10 A RMS (1.5 second maximum overload window)
  4. Matched Motor Power Range: 100 W – 750 W Parker brushless servo motors
  5. Supported Feedback Types: Incremental quadrature encoder, EnDat absolute position encoder, Parker Smart Encoder auto-recognition
  6. Native Communication Buses: CANopen, SERCOS II, RS232, Modbus RTU
  7. Control Modes: Position closed-loop, velocity closed-loop, torque closed-loop, electronic gear, electronic cam, programmable motion sequence
  8. External Command Interfaces: ±10 V analog velocity/torque reference, step/direction pulse train, isolated digital I/O
  9. Position Loop Resolution: 24-bit encoder position processing
  10. Protection Functions: Over-current, over-voltage, under-voltage, over-temperature, motor phase loss, encoder loss, emergency stop interlock
  11. Mount Form: Standard rack insert module for Parker AR series multi-axis rack chassis
  12. Operating Temperature Range: 0 °C – 45 °C cabinet ambient
  13. Certifications: CE EMC/LVD, UL508c, cUL industrial safety certification
  14. Net Weight: 1.2 kg

Functional Features

  1. Parker Smart Encoder automatic motor parameter detection; drive self-configures motor operating parameters without manual data entry
  2. Multi-axis synchronous motion coordination via CANopen real-time bus for gantry and packaging machine axis synchronization
  3. Built-in standalone motion programming language; execute positioning sequences without external motion controller
  4. Comprehensive onboard fault diagnostic system with non-volatile fault log storage
  5. Front panel multi-color LED array displaying power status, servo enable, bus communication and fault alarm codes
  6. Full galvanic isolation between mains power circuit, field I/O and encoder feedback circuits to block industrial electromagnetic interference
  7. Hot-swappable rack module design; single axis drive replacement without full rack power shutdown

Working Principle

Single-phase AC mains input passes internal EMI filter and full-wave rectifier to generate DC bus voltage for three-phase inverter power stage. The onboard 32-bit DSP motion processor receives motion commands from analog, pulse or fieldbus interfaces and reads high-resolution position feedback from the motor encoder. Closed-loop PID algorithm calculates three-phase sinusoidal current output for brushless motor stator windings to precisely regulate motor torque, speed and position. Smart Encoder detection circuit interrogates motor encoder memory on power-up to load motor rated voltage, current and pole count parameters automatically. Internal sampling circuits continuously monitor bus voltage, output current and power stage temperature; fault conditions immediately disable inverter switching and latch fault information to internal memory for host bus readout. CANopen/SERCOS communication interface synchronizes motion setpoints with adjacent rack-mounted servo drives for multi-axis coordinated movement.

Material Composition

  1. Module Housing: Black powder-coated aluminum alloy extruded frame with integrated passive heat sink fins
  2. Power Stage PCB: Aluminum base thermal conductive circuit board for IGBT power device cooling
  3. Digital Control PCB: FR-4 fiberglass signal board with isolated optocoupler I/O interfaces
  4. Rack Contact Pins: Gold-plated copper alloy backplane connector for multi-axis rack power and bus communication
  5. Wiring Terminals: Spring-clamp vibration-resistant insulated terminal blocks for motor power and feedback wiring

Structural Characteristics

  1. Standard AR series rack plug-in module form factor; multiple ARxxAE drives stacked vertically inside unified rack chassis sharing single AC mains input
  2. Vertical finned aluminum chassis design for vertical natural convection heat dissipation in rack cabinet
  3. Rear edge gold-plated backplane contact strip for shared DC bus and inter-axis communication bus
  4. Front panel centralized wiring terminals for motor power, encoder feedback and external I/O signals
  5. Mechanical locking latch on module side prevents vibration-induced disconnection from rack backplane

Advantage Highlights

  1. Smart Encoder auto-configuration drastically reduces equipment commissioning time for mixed motor axis systems
  2. Shared rack DC bus design eliminates separate power supply hardware for each individual axis, reducing cabinet component count
  3. Hot-swap module capability minimizes production downtime during single-axis drive maintenance replacement
  4. Multi-bus industrial communication compatibility integrates seamlessly with PLC, HMI and upper-level motion controllers from all mainstream automation brands
  5. Compact rack stacking form factor achieves ultra-dense multi-axis arrangement inside limited-size electrical cabinets
  6. Industrial-grade spring-clamp terminals maintain reliable wiring connection under continuous machine vibration

Applicable Industries

Packaging automation machinery, printing & converting equipment, textile processing machines, robotic pick-and-place systems, woodworking CNC routers, semiconductor packaging equipment, medical automation devices

Installation Requirements

  1. Install module exclusively inside matching Parker AR series multi-axis rack chassis; rack mounted vertically in IP54 rated industrial control cabinet
  2. Maintain minimum 15 mm vertical airflow gap between stacked drive modules inside rack
  3. Motor encoder wiring must use shielded differential twisted pair cable separated from high-current motor power cables
  4. Rack chassis connected to dedicated protective earth ground bus for EMI noise suppression
  5. Cabinet forced cooling fan mandatory for continuous full-load operation above 35 °C ambient temperature

Usage Precautions

  1. Do not apply AC mains voltage exceeding 264 VAC to input terminals; internal rectifier circuit permanent damage occurs
  2. Confirm encoder wiring pinout matching Parker Smart Encoder standard before power-on; miswiring triggers encoder loss fault
  3. Limit continuous operation above rated 4 A output current to maximum 1.5 seconds to avoid thermal shutdown
  4. Clear rack ventilation filter monthly to prevent dust accumulation blocking heat sink airflow
  5. Store spare modules in temperature-controlled low-humidity storage environment to prevent gold-plated backplane contact oxidation
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Parker AR-04AE-13574”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.