GE IS230TNRLH3E

Product Type: Dual-Port Redundant Ethernet Communication Module

Product Introduction:
The IS230TNRLH3E is a dual-port redundant 10/100 Mbps Ethernet communication module designed for GE Mark VIe control systems requiring network redundancy. It provides two independent Ethernet ports that can operate in active/standby or load-sharing mode, ensuring continuous communication even if one port or network path fails.

Category:
Description

Technical Specifications:

Parameter Value
Number of Ports 2 Ports (RJ-45)
Port Speed 10/100 Mbps (Auto-negotiation)
Redundancy Mode Active/Standby, Load-Sharing
Protocol Support TCP/IP, UDP/IP, Modbus TCP, SNMP, HTTP
Failover Time < 50 milliseconds
Maximum Cable Length 100 meters (328 feet) per port
LED Indicators Power, Link (x2), Activity (x2), Redundancy Status
Operating Temperature 0°C to 55°C (32°F to 131°F)
Power Supply +5V DC from Mark VIe Backplane (Redundant)
Dimensions Approximately 155 mm × 25 mm × 120 mm
Weight Approximately 0.28 kg
Certifications UL 61010-1, CE, FCC Part 15, IEC 61000-6-2, IEC 61000-6-4

Functional Features:

  • Two independent 10/100 Mbps Ethernet ports with auto-negotiation
  • Hardware-level redundancy with automatic failover under 50 ms
  • Active/Standby mode: One port active, second port on standby
  • Load-Sharing mode: Both ports active, traffic distributed
  • Modbus TCP master/slave functionality
  • Embedded SNMP agent with trap support
  • Redundant power input from Mark VIe backplane
  • Web-based configuration interface

Structural Features:

  • Dual RJ-45 connectors on front panel
  • 6 LED indicators including dedicated redundancy status LED
  • Hot-swappable module design
  • Conformal-coated PCB for industrial environment durability

Applicable Industries:

  • Critical Power Generation (Gas/Steam Turbine)
  • Nuclear Power Plant Control Systems
  • Oil & Gas Pipeline SCADA
  • Chemical Plant Safety Systems (SIS)

Installation Requirements:

  • Install in Mark VIe chassis with redundant power configuration
  • Connect two separate Ethernet cables to two independent network switches
  • Configure redundancy mode (Active/Standby or Load-Sharing) via configuration tool
  • Assign two unique IP addresses (one per port) or shared IP with failover

Usage Precautions:

  • Both ports must connect to separate network switches for true redundancy
  • Verify failover functionality after installation using diagnostics
  • Do not exceed 100 meters cable length per port
  • Maintain temperature below 55°C
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE IS230TNRLH3E”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.