ProSoft MVI56-MNETR Modbus TCP
- Technical Specifications
- Mechanical and Power Parameters
- It adopts a single-slot design compatible with the Controllogix 1756 backplane, enabling easy installation into Controllogix chassis without occupying excessive space.
- The backplane current load reaches 800 mA under 5 VDC and 3 mA under 24 VDC, matching the power supply requirements of Controllogix systems for stable operation.
- Communication Parameters
- It is equipped with a 10/100 Mbps Ethernet interface with auto-crossover detection, using an RJ45 connector suitable for Cat5 cables, and it supports Ethernet/IP pass-through communication.
- It supports storage and transfer of up to 5000 16-bit registers with the Controllogix processor through block transfer or side-connect interface. Client parameters are configurable, including a minimum response delay ranging from 0 to 65535 milliseconds, and it also supports floating-point data types.
- Environmental and Display Parameters
- The operating temperature ranges from 0 °C to 60 °C, and the storage temperature ranges from -40 °C to 85 °C. It can operate normally in 5% to 95% relative humidity environments without condensation.
- It is equipped with a 4-character scrolling alphanumeric LED display that shows module version, IP address, application port settings and error information, along with LED indicators for module status, application status and error status.
- Mechanical and Power Parameters
ProSoft 6104-WA-PDPM Wireless PROFIBUS DP Gateway Master Module
Technical Specifications
- Wireless Communication Parameters
- It operates in the 2.4 GHz frequency band ranging from 2400 MHz to 2483.5 MHz and complies with the IEEE 802.11 b wireless standard.
- The wireless data rate can reach up to 11 Mbps, with an output power of 32 mW (15 dBm) and a maximum open-air transmission distance of 400 meters.
- It is equipped with two RP-SMA connectors that support antenna diversity, which enhances the stability of wireless signal reception and transmission.
- PROFIBUS DP Related Parameters
- It is equipped with an RS-485 PROFIBUS DP interface and supports PROFIBUS DP and DP-V1 protocols.
- The communication baud rate of PROFIBUS DP ranges from 9.6 kbps to 12 Mbps, and it can support up to 125 PROFIBUS DP slave devices.
- Power and Mechanical Parameters
- It has a power supply requirement of 10 - 36 VDC, adapting to different industrial power supply environments.
- It adopts a DIN rail mounting design with an IP20 protection rating, which fits the standard installation specifications of industrial control cabinets and prevents dust intrusion effectively.
ProSoft MVI69-MNET Modbus TCP
- Technical Specifications
- Power and Mechanical Parameters
- It has a maximum current load of 800 mA at 5 VDC power supply. It adopts a standard 1769 single-slot design and is compatible with the 1769 backplane, which can be smoothly installed into the corresponding CompactLogix chassis.
- It is recognized as a standard input and output module by the CompactLogix system, enabling unobstructed access to processor memory for smooth data transfer between the processor and the module.
- Communication Parameters
- It is equipped with a 10/100 Base-T Ethernet-compatible interface. The server driver can support connections to up to five Modbus TCP/IP clients through service port 502 with standard MBAP messaging, and another five clients through Modbus RTU/ASCII on service port 2000.
- The client driver can actively read and write data with Modbus TCP/IP-compatible devices, and a single client can support up to 100 commands that can be sent to one or multiple servers. All data mapping of the module starts from Modbus register 40001.
- Compatibility Parameters
- It is compatible with all CompactLogix and MicroLogix 1500 LRP controllers, but it cannot be used with 1769-QBFC1B, 1769-L16X and 1769-L18X models. It supports Enron, Daniels and other floating-point data types to meet diverse data processing needs.
- Power and Mechanical Parameters
ProSoft MVI56-MDA4 MDA Scientific CM4 Gas Analyzer Master Module
Technical Specifications
- Mechanical and Backplane Specifications
- It is compatible with the 1756 backplane, adopts a single - slot design, and can be installed in both local and remote racks of ControlLogix chassis. It is recognized as a standard input and output module by the ControlLogix system and can access the processor memory smoothly.
- Electrical Parameters
- The input voltage ranges from 110V AC to 240V AC, and the operating frequency is 50Hz or 60Hz. The maximum power consumption does not exceed 5W, which shows low energy consumption and has little impact on the overall power load of the industrial control system.
- Communication and Measurement Parameters
- It supports Modbus RTU and Modbus ASCII communication protocols, is equipped with two RS - 232 communication ports for connecting to CM4 gas analyzers, and an RJ45 serial port for configuration operations.
- The sampling rate can reach up to 10Hz. For common gases, the measurement range includes 0 - 25% volume for oxygen and 0 - 20000 ppm for carbon monoxide, with a measurement accuracy of ±0.5%.
ProSoft AN-X2-AB-DHRIO EtherNet
- Technical Specifications
- Power Supply Parameters
- The typical power consumption is 200mA at 12V DC or 100mA at 24V DC, with a maximum power consumption of 2.4W. It adapts to the common low - voltage DC power supply environment in industrial sites and has low overall energy consumption.
- Communication Parameters
- It is equipped with one RJ45 10/100 Mbps Ethernet port and one DH+/Remote I/O port. It supports DH+, Remote I/O and EtherNet/IP protocols and now supports DH+ migrations on SLC networks.
- It supports all DH+ and Remote I/O baud rates, which are 57.6k baud, 115.2k baud and 230.4k baud, and Remote I/O addressing ranges from 0 to 76 octal.
- Environmental and Physical Parameters
- The operating temperature ranges from 0°C to 50°C, and the storage temperature ranges from -40°C to 85°C. It can withstand extreme temperature changes in both indoor and outdoor industrial environments.
- The relative humidity tolerance is 5% to 95% non - condensing. Its dimensions are 107mm x 126mm x 34mm excluding connectors, and it weighs approximately 310 grams. It supports DIN rail mounting for convenient integration into industrial control cabinets.
- Power Supply Parameters
ProSoft 5601-RIO-MCM Remote I/O to Modbus Master
- Technical Specifications
- Electrical Parameters
- The power supply voltage ranges from 18VDC to 32VDC, with a maximum current load of 500mA at 32VDC.
- It adopts a passive power design that draws power directly from the connected Remote I/O scanner, eliminating the need for an independent external power supply and simplifying the wiring layout.
- Communication Parameters
- It supports Remote I/O, Modbus RTU and Modbus TCP protocols. The Modbus serial ports support baud rates ranging from 110 baud to 115k baud, with configurable stop bits of 1 or 2, data sizes of 7 or 8 bits, and parity options including none, even and odd.
- The Remote I/O interface supports baud rates of 57.6k, 115k and 230k, and can realize block data transmission with the scanner, supporting BTR commands up to 63 words and BTW commands up to 64 words.
- Environmental and Physical Parameters
- The operating temperature ranges from -40°C to 85°C, and the storage temperature ranges from -40°C to 85°C. It can adapt to extreme temperature changes in both indoor and outdoor industrial sites.
- The relative humidity tolerance is 5% to 95% non-condensing. Its dimensions are 222.25mm x 88.90mm x 38.10mm and it weighs 0.72kg.
- Electrical Parameters
MTL 5532 Single-Channel Pulse Isolator with Analog and Relay Alarm Outputs
Technical Specifications
- Power Supply Parameters
- The power supply voltage ranges from 20V DC to 35V DC. The maximum power consumption of the module is 2.0W, and it weighs 140 grams, which helps reduce the overall energy consumption and weight of the control cabinet.
- The maximum voltage tolerance of the related circuits reaches 253V RMS, which can adapt to the voltage fluctuations in industrial power supply environments.
- Input and Output Parameters
- For proximity detector input, it provides 7.0V - 9.0V DC excitation with a nominal 1kΩ resistance. The output turns on when the input exceeds 2.1mA and turns off when the input is less than 1.2mA, with a nominal switching hysteresis of 0.2mA.
- The safe - area pulse output has a maximum delay of 10μs, a maximum off - state voltage of 35V, a maximum off - state leakage current of 10μA, a maximum on - state resistance of 25Ω and a maximum on - state current of 50mA.
- The analog output signal ranges from 4mA to 20mA, with an accuracy better than 20μA at 20°C and a temperature drift of less than 14μA/°C. The maximum load resistance it can drive at 20mA is 450Ω.
- The relay alarm output can bear a maximum of 0.5A current at 35V DC.
MTL 5517 Two-Channel Switch
Technical Specifications
- Electrical Parameters
- The intrinsic safety parameters for hazardous area terminals include an open - circuit voltage of 10.5V, a short - circuit current of 14mA, and zero input capacitance and inductance. The maximum voltage tolerance for related circuits reaches 253V RMS.
- The safe - area relay contacts can switch up to 253V RMS, 2A RMS and 100VA. In Zone 2, the relay contacts can switch up to 35V, 2A and 100VA, and the DC supply voltage for specific non - hazardous area circuits can be up to 35V.
- The maximum current consumption is 35mA at 24V DC, and the corresponding power dissipation is 0.84W.
- Response and Environmental Parameters
- The maximum response time of the module is 10ms, ensuring rapid response to signal changes and fault events in the field.
- The operating temperature ranges from -20°C to +60°C. It requires installation in an enclosure with at least IP54 protection level when used in Zone 2.
MTL 5053 31.25kbit/s H1 Fieldbus Isolator with Integrated Power Supply
Technical Specifications
- Power Supply Parameters
- The safe - area input voltage ranges from 20V DC to 35V DC. When the output load is 80mA, the typical current consumption is 135mA at 24V DC, and the current consumption is 105mA at 35V DC.
- It provides a stable 18.4V ±2% power supply for fieldbus devices in hazardous areas, with a maximum output current of 80mA and a DC impedance of 105Ω ±3%.
- Signal and Isolation Parameters
- The digital signal transmission rate is fixed at 31.25kbit/s, which is fully compatible with H1 fieldbus systems and meets relevant fieldbus standards.
- The isolation voltage between safe - area and hazardous - area circuits and the power supply reaches 250V AC. The parameters of terminals 1 and 2 are 22V, 102Ω and 216mA, and the maximum voltage tolerance is 250V RMS or DC.
- Physical and Environmental Parameters
- The operating temperature ranges from -20°C to +60°C. If installed non - vertically, the maximum allowable operating temperature is reduced to 45°C.
- It adopts 10mm spacing DIN rail installation. A green LED indicator is configured to display the power supply status. The shipping weight of the product is 1kg.
MTL 4549Y Dual-Output Intrinsically Safe Isolator with Fault Detection
Technical Specifications
- Signal Parameters
- The input signal is a 4 - 20mA floating signal from the safe-area controller. The digital signal bandwidth ranges from 500Hz to 10kHz, which can meet the transmission needs of most industrial digital communication signals.
- The maximum load resistance reaches 800Ω at 16V and 20mA, and the minimum load resistance is 90Ω, with short-circuit detection activated when the resistance is less than 50Ω. The output resistance exceeds 1MΩ, ensuring stable signal output.
- Accuracy and Stability
- The transfer accuracy is better than 20μA at 20°C, and the temperature drift is less than 1.0μA/°C, which minimizes signal distortion caused by temperature changes.
- The ripple of input and output circuits is less than 40μA peak, and the module settles to the final value within 100ms, ensuring rapid response to signal changes and stable transmission.
- Safety and Functional Parameters
- It has an under-range capability within 1mA and an over-range capability of up to 24mA when the load is 520Ω or less. When a line fault occurs, the current entering the terminals drops to a preset level to protect the circuit.
- It achieves 253V AC or DC isolation between circuits, which can effectively prevent electrical interference between different circuits and ensure the safety of the system.
MTL 4544 Dual-Channel Intrinsically Safe 4-20mA HART Repeater Power Supply
Technical Specifications
- Input Parameters
- The input signal range for the hazardous area covers 0 to 24mA, which includes over-range signals. It supplies a 16.5V voltage to the transmitter when the current reaches 20mA.
- It is compatible with 2-wire or 3-wire transmitters. Separately powered current sources like 4-wire transmitters can also be connected, but HART communication is not available for such connections.
- Output Parameters
- The safe-area output signal ranges from 4 to 20mA, with an under/over-range of 0 to 24mA. For the MTLX544 variant, the safe-area load resistance can be 0 to 360Ω at 24mA and 0 to 450Ω at 20mA.
- The MTLX544S variant acts as a current sink with a maximum safe-area load of 600Ω and supports a maximum voltage source of 24V DC. The safe-area circuit has an output resistance exceeding 1MΩ and a ripple of less than 50µA peak-to-peak.
- Accuracy and Response Performance
- The transfer accuracy is better than 15µA at 20°C, and the temperature drift is less than 0.8µA/°C, ensuring minimal signal distortion due to temperature changes.
- The module settles to within 10% of the final value within 50µs, enabling rapid response to changes in the transmitter's input signals.
MTL 4541 Single-Channel Intrinsically Safe 4-20mA HART Repeater Power Supply
Technical Specifications
- Input Parameters
- The hazardous - area input signal range covers 0 to 24mA, including over - range signals. It supplies 16.5V voltage to the transmitter when the current is 20mA.
- It is compatible with 2 - wire or 3 - wire 4 - 20mA transmitters, and can also connect to separately powered current sources such as 4 - wire transmitters, though HART communication is not supported for the latter.
- Output Parameters
- The safe - area output signal range is 4 - 20mA, with an under/over - range of 0 - 24mA. The load resistance can reach 360Ω at 24mA and 450Ω at 20mA.
- The safe - area circuit has an output resistance greater than 1MΩ, and the circuit ripple is less than 50µA peak - to - peak, ensuring stable output signals.
- Accuracy and Response Performance
- The transfer accuracy is better than 15µA at 20°C, and the temperature drift is less than 0.8µA/°C. The linearity error is less than 0.05%, and the temperature coefficient is 0.01% per °C.
- The module settles to within 10% of the final value within 50µs, enabling rapid response to signal changes.