LEM LF1005-SSP16

Product Name​
LEM LF 1005-S/SP16 closed-loop Hall-effect current transducer.
Product Introduction​
LF1005-S/SP16 is a high-current closed-loop transducer for AC, DC and pulsed current measurement. It provides galvanic isolation between the primary conductor and the measuring circuit and outputs a voltage signal proportional to primary current for power converters, drives and protection systems.
Category:
Description
Technical Specifications​
Nominal primary current 1005 A RMS. Measurement range 0 to ±1500 A peak. Conversion principle closed-loop Hall/compensated Hall. SP16 voltage output ±4 V on the named variant. Accuracy at nominal and 25 °C ≤ ±0.5%. Linearity error < 0.1%. Offset referred to primary ≤ ±0.3 mA. Bandwidth -3 dB DC to 100 kHz. Response time ≤ 1 µs. Supply voltage ±15 V DC ±5%. Secondary consumption ≤ 55 mA. Isolation voltage RMS 50 Hz, 1 minute, 3 kV. Operating temperature -40 °C to +85 °C. Storage temperature -50 °C to +90 °C. Protection class IP20 for PCB/panel mounted versions. Conductor aperture sized for busbar or cable pass-through in LF form factor.
Function Features​
Galvanic isolation, wide AC/DC/pulsed bandwidth, fast response for short-circuit detection, low offset, high linearity, immunity to external magnetic disturbance through compensated loop, voltage output for direct ADC/controller interface.
Structure Characteristics​
Magnetic core with air-gap Hall sensor, compensation winding, signal-conditioning PCB, insulated primary pass-through aperture, molded housing, secondary connector/terminal interface, panel/PCB mounting features.
Working Principle​
Primary current creates magnetic flux in the core. The Hall sensor detects flux error; the electronics drive a compensation current through the secondary winding to null the flux. The compensation current, converted to a voltage output, is proportional to primary current and reproduces AC, DC or pulsed waveforms.
Installation Requirements​
Mount with adequate clearance for the primary busbar/cable aperture. Use specified ±15 V supply with filtering. Route output and power cables away from high-noise switching paths where practical. Torque primary connections to system ratings and verify creepage/clearance for the operating voltage.
Usage Precautions​
Do not exceed 1005 A continuous or ±1500 A peak without thermal derating review. Respect ±15 V supply tolerance and 3 kV isolation rating. Avoid mechanical stress on the primary aperture. Calibrate offset during commissioning; verify zero output with no primary current. Replace if isolation testing fails or housing is damaged.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “LEM LF1005-SSP16”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.