HIMA X-AO1601

Product Name:​ HIMax 16-Channel Safety Analog Output Module
Product Introduction:​ Part of the HIMA HIMax safety instrumented system (SIS) family, built to drive final control elements such as control valves, positioners and actuators in SIL 3 rated applications.
Category:
Description
Technical Specifications:
  • Channels: 16 single-ended analog outputs (8 redundant pairs supported)
  • Output Signal: 4–20 mA nominal, 0–22.5 mA operating range
  • Resolution: 16 bit (10,000 digits in SILworX), LSB ≤ 2 µA
  • Accuracy: ≤ ±0.2 % FS at 25 °C, ≤ ±0.5 % FS over full temperature range
  • Load: 600 Ω max resistive, 1 mH max inductive, 100 µF max capacitive (parallel to resistive)
  • Settling Time: 5 ms
  • Fault Shutdown Time: 16 ms (de-energize to trip)
  • Backplane Supply: 24 VDC (19.2–30 VDC), SELV/PELV, ~0.6 A idle / 1.3 A max
  • Operating Temperature: 0 to +60 °C (some references –25 to +70 °C)
  • Storage Temperature: –40 to +85 °C
  • Humidity: 5–95 % RH non-condensing
  • Protection: IP20, pollution degree 2
  • Dimensions: 310 × 29.2 × 230 mm, ~1.2 kg
  • Safety: IEC 61508 SIL 3
    Functional Features:​ Per-channel open-circuit detection, configurable fault-safe behavior (hold/reset), background self-test, redundant architecture support, HART pass-through compatible via terminal board, LED diagnostics, SILworX configuration.
    Structure & Connection:​ Plugs into HIMax rack backplane; requires separate X20-style connector board (X-CB 014 01/02/03/04) for screw or plug termination; mechanical coding prevents misinsertion.
    Installation Requirements:​ 19-inch HIMax rack slot, horizontal or vertical DIN rail mounting inside control cabinet, ESD handling mandatory.
    Application Scenarios:​ ESD, Fire & Gas, turbine protection, burner management, petrochemical, oil & gas, power generation.
    Usage Notes:​ Only authorized personnel may handle modules; verify spare module setting in redundancy groups; perform 10-year proof test per HIMA HI 801 003 E; do not hot-plug in energized Ex loops without isolation.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “HIMA X-AO1601”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.