Honeywell FC-RPB2N12

Product Name: Relay Base / Output Base 12 Channel
Product Introduction: The FC-RPB2N12 is a 12-channel​ relay output base/terminal board for the Honeywell FSC (Fail Safe Control) safety system, providing field wiring termination and isolation for relay modules.
Category:
Description
Technical Specifications:
  • Channels: 12 Relay Output​ interfaces
  • Voltage Rating: Compatible with 24 VDC, 110 VAC, 220 VAC​ (dependent on mounted relay)
  • Current Rating: Typically 2 A – 5 A​ per channel (relay dependent)
  • Isolation: 2500 VAC​ field-to-control isolation
    Functional Features: Distributes control signals to field relays; removable screw terminal blocks for easy wiring; high-voltage isolation barrier between logic and field sides.
    Performance Parameters:
  • Operating Temp: -20°C to +60°C
  • Storage Temp: -40°C to +85°C
  • Protection: IP20 (cabinet mounted)
    Material Composition: Flame-retardant thermoplastic terminal housing; tinned copper alloy contacts; steel mounting chassis.
    Structural Characteristics: Plugs onto FSC rack backplane or mounts on DIN rail; detachable terminal blocks; keying to prevent wrong module insertion.
    Working Principle: The safety processor drives low-voltage logic to the FSC relay card seated on this base; the base routes these signals to field-wired relay coils/contacts isolating hazardous voltage from the control bus.
    Advantages Highlights: Simplifies field wiring with removable terminals; supports high-voltage AC/DC loads; integral to SIL 3 loops when paired with certified FSC modules.
    Applicable Industries: Process Safety (ESD), Fire & Gas, Burner Management, Heavy Manufacturing.
    Model Series: Honeywell FSC Series 100/101/102 Termination Bases.
    Installation Requirements: Snap onto FSC rack or DIN rail; torque terminals to spec; ensure earth ground is connected; verify relay card compatibility (FC-DO series).
    Usage Precautions: Do not exceed relay contact voltage/current ratings; ensure isolation barriers are not bridged; check wiring for loose strands causing cross-talk; verify SIL certification context.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Honeywell FC-RPB2N12”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.