Honeywell FC-SDO-0824

  • Product Name:​ Honeywell Safety Manager Series Fail-Safe Digital Output (SDO) Module, Model FC-SDO-0824
  • Product Introduction:​ This is a certified safety-rated digital output module designed for Honeywell Safety Manager (Experion PKS SCS / FSC) systems. It executes safety logic decisions by switching 24 VDC field loads such as solenoids, alarms, and pilot valves. On loss of communication or internal fault, outputs revert to a predefined safe state (de-energized).
Category:
Description
  • Key Features:
    • 8 independent solid-state source-type (PNP) output channels, 24 VDC
    • Per-channel current up to 0.5 A (some variants 0.55 A / 13 W load); module total typically 2.0 A
    • SIL 3 certified per IEC 61508; TÜV approved; supports 1oo2 / 2oo3 voting in TMR architecture
    • Integrated suppression diode on each channel for inductive load protection
    • Continuous onboard diagnostics — open-circuit, short-to-ground, short-to-supply, and load-current deviation detection (>99% diagnostic coverage)
    • Watchdog timer forces fail-safe deactivation if valid telegram not received
    • Hot-swappable in rack; LED per channel + module-level RUN/FAULT/ACTIVE
  • Performance Parameters:
    • Operating Voltage: 24 VDC (via rack backplane, typical range 18–32 VDC)
    • Response Time: < 20 ms (logic solve to output action)
    • Switching Frequency: up to ~250 kHz rated for diagnostics; practical load switching slower
    • Operating Temp: -20 °C to +70 °C (some references -40 °C to +70 °C)
    • Humidity: 5 %–95 % RH non-condensing
    • Isolation: Channel-to-channel and channel-to-system galvanic isolation
    • Certifications: SIL 3 (IEC 61508), EN 61511, FM Cl. I Div. 2, ATEX/IECEx optional
  • Structure & Material:​ Metal/ABS housing with DIN-rail or rack-backplane mount; gold-plated contacts on removable terminal block base (FC-T08 / FC-T16 series)
  • Installation & Notes:
    • Insert into dedicated Safety Manager I/O slot; ensure correct terminal base is fitted
    • Use properly sized flyback diodes for inductive loads > 13 W or rely on integrated suppression
    • Do NOT exceed 0.5 A per channel; observe total module current derating
    • Verify SIL architecture before deployment in ESD / F&G loops
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Honeywell FC-SDO-0824”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.