Working Principle: Emits ultrasonic pulses (200 kHz transducer); measures round-trip echo time to calculate target distance; internally compensates for air temperature; converts result to analog signal and/or evaluates against configurable switching thresholds.
Measuring Range: 200 mm – 2,000 mm (usable working range 200–1,300 mm typical, max. detectable to 2,000 mm)
Blind Zone: 200 mm
Transducer Frequency: 200 kHz
Resolution: 0.18 mm – 0.57 mm (depending on analog window setting)
Repeatability: ±0.15 %
Accuracy: ±1 % of measured value (with internal temperature drift compensation)
Supply Voltage (Ub): 9 V DC – 30 V DC, reverse polarity protected
No-load Current Consumption: ≤ 80 mA
Outputs:
-
Output 1 — Analog: 4–20 mA or 0–10 V (selectable rising/falling characteristic, short-circuit protected; 0–10 V requires Ub ≥ 15 V)
-
Output 2 — Switching: PNP, Imax = 200 mA, NO/NC selectable, short-circuit protected
-
Output 3 — Switching: PNP, Imax = 200 mA, NO/NC selectable, short-circuit protected
Response Time: 110 ms (typical); delay prior to availability < 300 ms
Switching Hysteresis: 20 mm
Inputs: 1× COM input; synchronization input supported
Connection Type: 5-pin M12 (A-coded) male connector
Housing Material: Nickel-plated brass sleeve; end caps and sensing face in PBT (Polybutylene Terephthalate) and TPU (Thermoplastic Polyurethane)
Transducer Membrane Material: Polyurethane foam with glass-filled epoxy resin
Protection Class: IP67 per EN 60529
Operating Temperature: –25 °C to +70 °C
Storage Temperature: –40 °C to +85 °C
Weight: ≈ 150 g
Display / Configuration: 3-digit 7-segment LED + 2× three-color status LEDs; 2 pushbuttons for Teach-in and numeric config via TouchControl; compatible with LinkControl software (LCA-2)
Temperature Compensation: Internally active
Synchronization / Multiplex: Supported (multiple sensors can be synchronized to avoid crosstalk)
Applicable Industries: Automotive manufacturing, packaging & filling lines, logistics/warehousing (pallet/stack height), food & beverage (non-hygienic washdown zones), AGV obstacle detection, paper & printing (web edge/double-sheet detection)
Installation Requirements: Mount with M30 threaded barrel using lock nuts; ensure transducer face is unobstructed within blind zone; avoid mounting multiple units facing each other without synchronization; sensor axis should be perpendicular to flat target for best accuracy.
Usage Notes: Do not expose transducer membrane to aggressive solvents or mechanical impact; for transparent/fluffy/very soft materials verify echo return in application; analog output load resistance must comply with loop specs (≥ 500 Ω for current output); periodic re-teach may be required if acoustic environment changes significantly.