Core Technical Specifications
- Signal Input Channels: 6 multi-purpose analog voltage/current input channels
- Input Signal Ranges: 0–120 V AC voltage transformer signals, 0–5 A AC current transformer signals
- Signal Sampling Resolution: 16-bit high-speed analog-to-digital conversion
- Internal Communication Bus: VME industrial rack backplane bus, Profibus DP auxiliary field bus
- Auxiliary Power Supply Input: 100–125 V AC / 220–240 V AC dual universal mains supply
- Operating Temperature Range: -40 °C to +85 °C wide industrial temperature rating
- Storage Temperature Range: -50 °C to +90 °C
- Ingress Protection Class: IP23 with complete cabinet housing assembly
- Mechanical Form Factor: Standard 6U VME rack card form factor
- Net Weight: 0.65 kg
Functional Features
- Synchronous multi-channel sampling of generator three-phase voltage and current CT/PT secondary signals
- Real-time calculation of generator active power, reactive power, power factor, and rotor excitation demand
- Built-in anti-aliasing low-pass filtering to suppress grid high-frequency harmonic interference
- On-board overvoltage, overcurrent, and signal loss fault detection with front-panel alarm LEDs
- Profibus DP bus communication transmits real-time generator operating data to central plant SCADA systems
Working Principle
Secondary voltage and current signals from generator potential transformers (PT) and current transformers (CT) enter the module’s isolated signal conditioning circuits, which scale and filter raw AC waveforms. The conditioned analog signals feed the 16-bit multi-channel ADC chip for synchronous digital sampling. An on-board FPGA computes real-time generator electrical parameters and transmits calculated excitation demand setpoints to the main AVR control logic via the VME backplane bus. Real-time operating data is simultaneously transmitted to plant SCADA via the Profibus DP field bus interface.
Material & Structural Characteristics
- Main PCB substrate: High-temperature FR-4 PCB with full conformal anti-corrosion coating
- Signal isolation components: High withstand voltage isolation transformers for CT/PT input channels
- Module housing: Cold-rolled steel rack card frame with black anti-corrosion electrostatic coating
- Field wiring terminals: Screw-type brass terminal blocks with anti-loosening spring washers
- VME backplane connector: Gold-plated multi-pin spring contact edge connector
Core Advantages & Highlights
- Wide -40 °C to +85 °C operating temperature range adapts to unconditioned power station cabinet environments
- Full galvanic isolation between CT/PT field circuits and internal control logic eliminates transformer surge damage
- Native VME and Profibus dual bus compatibility integrates seamlessly with Alstom Microrec excitation control platforms
- Synchronous multi-channel sampling ensures accurate power factor and excitation demand calculation
- Rugged industrial mechanical construction withstands continuous power station vibration conditions
Applicable Industries
Large thermal power generator excitation control, hydroelectric synchronous generator AVR systems, combined-cycle gas turbine generator voltage regulation, wind farm synchronous generator grid stabilization control
Installation Mandatory Requirements
- Install within standard 6U VME rack with minimum 25 mm vertical ventilation clearance above and below the module
- Separate CT/PT secondary signal wiring from high-voltage power cables by minimum 30 cm distance
- All CT secondary wiring must include dedicated short-circuit terminal blocks for maintenance safety
- Auxiliary AC power input must incorporate surge suppression protection against grid voltage transients
- Execute full CT/PT signal calibration after module installation before generator unit commissioning
Operation & Maintenance Precautions
- Never disconnect CT secondary wiring while the generator unit remains energized to avoid dangerous open-circuit voltage generation
- Conduct full signal channel calibration every 24 months of continuous generator operation
- Avoid exposure to hydrogen gas leakage environments without sealed cabinet air circulation
- Disconnect auxiliary AC power supply before removing the module from the VME rack backplane
- Store spare modules in temperature-controlled dry storage with anti-static packaging to preserve conformal coating integrity