Watlow CAS200 CLS216

Product Brief Introduction

Rack-mounted multi-loop precision temperature control unit manufactured by Watlow thermal control brand, CLS216 specification supports 16 independent PID temperature control loops, dedicated to centralized temperature regulation of multi-point heating and cooling industrial process equipment.
Category:
Description

Technical Specifications

  • Model Core Configuration: CAS200 rack base + CLS216 16-channel PID temperature control daughter card
  • Total Independent Control Loops: 16 channels per CLS216 module card
  • Supported Temperature Input Sensors: K, J, T, S, R thermocouple; PT100, PT1000 platinum thermal resistance
  • PID Control Output Types: SSR solid state relay drive pulse output, 4-20mA analog proportional output, relay contact switch output
  • Power Supply Input: 24V DC ±10% rack backplane bus power supply
  • Control Temperature Measurement Range: -200°C ~ +1800°C full sensor compatible range
  • Operating Ambient Temperature: 0°C ~ +50°C rack cabinet continuous operation
  • Communication Interface: RS485 Modbus RTU standard upper host communication port

Functional Features

  1. 16 independent fully isolated PID temperature control loops with separate proportional, integral, derivative parameter setting per channel
  2. Built-in auto-tuning PID algorithm for automatic calculation of optimal control parameters for different heating loads
  3. Multi-segment temperature ramp soak program curve programming for batch thermal process production
  4. Independent high/low temperature alarm threshold configuration for each channel, relay alarm contact output
  5. Sensor open-circuit, short-circuit, over-temperature hardware fault detection for every temperature input channel
  6. Modbus RTU communication realizes remote parameter modification, real-time temperature data reading and program curve upload/download

Performance Parameters

  • Single Channel Temperature Measurement Accuracy: ±0.1°C full scale platinum resistance; ±0.3°C thermocouple
  • PID Control Loop Sampling Period: 100ms synchronous sampling for all 16 channels
  • Temperature Ramp Rate Adjustment Range: 0.1°C/min ~ 999.9°C/min arbitrary setting
  • Alarm Response Trigger Time: ≤150ms after temperature exceeds preset threshold
  • Communication Data Refresh Speed: Minimum 200ms full 16-channel temperature data upload cycle

Material Composition

  • CAS200 Rack Base Housing: Aluminum alloy extruded rack frame with anti-corrosion anodized coating
  • CLS216 Daughter Card Substrate: FR-4 multi-layer isolation circuit board with independent channel isolation circuits
  • Input Isolation Components: Small signal isolation transformers for each temperature sensor channel
  • Output Drive Components: Optocoupler isolation chips
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Watlow CAS200 CLS216”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.