Product Brief Introduction
- Woodward 5501-381 is factory calibrated plug-in switching power supply exclusively designed for Woodward MicroNet TMR triple redundant turbomachinery control chassis, responsible for converting input AC power into stable DC working bus voltage for all CPU, I/O and communication modules installed inside TMR chassis.
- This product supports hot-swap online replacement under full system live running state without interrupting continuous power supply of entire TMR control rack, which is core redundant power configuration for critical non-stop power generation equipment control cabinet.
- Every finished unit passes full-load aging test, input surge withstand test, insulation voltage test and four-channel fault indicator functional inspection before factory delivery; each single module carries exclusive serialized production number for full lifecycle spare part traceability management.
- It matches standard MicroNet TMR 14-slot VME backplane chassis, maximum two identical 5501-381 modules can be deployed inside one single TMR chassis for dual redundant power parallel backup configuration.
3. Technical Specification
- Rated AC input voltage: 220VAC, allowable input fluctuation range: 187VAC ~ 242VAC
- Input rated frequency range: 47Hz ~ 63Hz industrial universal AC frequency band
- Max rated input apparent power: 1250VA, maximum input rated current: 6.7A
- Input overcurrent protection configuration: built-in 10A time-delay type input fuse at AC input terminal
- DC output rated specification: DC24V stabilized bus output, continuous rated output current: 30A per single module
- AC input power hold-up time: 1 full AC cycle under rated 220VAC input condition during instantaneous power dip
- Overall outer dimension: 203.2mm(L) ×152.4mm(W) ×50.8mm(H)
- Net single module weight: 0.70kg excluding external connecting cable
- Protection grade after cabinet installation: IP20 compliant with IEC60529 standard
- Continuous working ambient temperature range: -40℃ ~ +70℃; storage extreme temperature range: -55℃ ~ +85℃
- Working relative humidity scope: 5%RH ~95%RH non-condensing environment without corrosive gas accumulation
- EMC certification standard: CE, UL508, ISO9001 factory certification fully passed
- Vibration resistance index: comply with IEC60068-2-6 standard, withstand 3g RMS vibration within 10Hz~500Hz frequency range during continuous operation
4. Functional Features
- Built-in full-isolation switching power conversion circuit, completes AC220V to stabilized DC24V conversion and electrical isolation between input AC side and control cabinet DC bus side to cut common-mode ground interference path.
- Front panel equipped with four independent status LED indicator lamps, separately marked Input Fault, Power Fault, Overtemperature and System OK for real-time running status visualization monitoring.
- Standard VME64X rear plug connector structure supports hot-plug disassembly and replacement; internal instant surge suppression circuit automatically stabilizes bus voltage during module plugging action to avoid system undervoltage trip.
- Internal dual-level overvoltage, overcurrent and overtemperature three-stage protection circuit; corresponding protection action triggers automatic cut-off of power output once any abnormal operating parameter exceeds rated threshold.
- Built-in parallel current-sharing control circuit, two pieces of 5501-381 modules can run in parallel redundant mode inside one TMR chassis with balanced load current distribution automatically assigned between dual power units.
- Embedded passive EMI filter at AC input terminal to filter high-frequency clutter and power-frequency harmonic interference transmitted from factory AC power grid side.
- Reserved external fault dry-contact signal output terminal on module side for connecting cabinet DCS remote fault alarm system to realize remote abnormal state upload.
- Surface reserved white label marking area for manual filling of equipment unit number and installation slot number for later maintenance management work.
5. Performance Parameter
- DC output voltage precision: ±0.5%FS under rated full-load 30A output and 25℃ standard ambient condition
- Output long-term continuous drift: ≤0.04%FS per 24-hour full-load uninterrupted running under constant-temperature environment
- Parallel current sharing deviation between dual redundant modules: ≤3% of rated single-module output current under random load change condition
- Input power hold-up characteristic: DC output voltage maintains above DC21.6V within one AC cycle after sudden AC input power loss at rated operating status
- Insulation resistance between AC input circuit and DC output circuit: ≥1500MΩ tested with DC500V megohmmeter under normal ambient
- Withstand voltage value between input and output: AC2000V/1min no breakdown and no creepage discharge phenomenon
- Module overtemperature protection trigger threshold: internal core temperature reaches +85℃ to activate automatic output shut-off protection
- AC input surge withstand capacity: withstand 2kV instantaneous surge pulse at input port per IEC61000-4-5 standard without internal component damage
6. Material Composition
Core PCB Circuit Board
- Substrate material: FR-4 TG150 high-temperature flame retardant epoxy glass fiber board, 6-layer laminated PCB structure; power layer copper foil thickness 35μm, signal layer copper foil thickness 18μm, board surface adopts lead-free HASL anti-oxidation coating.
Outer Metal Housing & Heat Dissipation Radiator
- Outer shielding shell: cold-rolled SPCC steel plate with black matte electrophoretic anti-corrosion coating, plate thickness 1.2mm; built-in radiator fin: extruded aluminum alloy with natural oxidation surface treatment for power tube heat dissipation.
Connector & Conductive Components
- Rear VME plug connector plastic base: UL94-V0 grade glass fiber filled PA66 nylon; internal contact pins: phosphor bronze with 0.8μm full gold plating for anti-oxidation stable conduction.
- AC input terminal conductive inserts: H62 brass raw material with nickel plating surface anti-corrosion treatment; fixed assembly screws: SUS304 stainless steel fasteners.
Internal Electronic Components
- Main switching power tube: industrial wide-temperature grade IGBT power device; input filter capacitor: high-temperature aluminum electrolytic capacitor and polypropylene film capacitor combination; protection components: SMD TVS diode, organic PTC resettable fuse and bimetallic overtemperature cut-off switch.
7. Structural Characteristics
- Overall split three-section compact structure: front panel indicator section, middle internal circuit and radiator section, rear VME plug connector section, three parts fixed with evenly distributed stainless steel anti-loose screws into integrated whole unit.
- Front panel four LED lamps arranged in horizontal equidistant layout with corresponding silk-screen fault function identification text printed directly on panel surface.
- Bottom side reserved integrated limit guide rail structure matching MicroNet TMR chassis VME slot track to ensure vertical smooth plug-in without lateral deflection during installation.
- Upper and lower shell surfaces designed with dense strip-shaped ventilation slot for natural convection heat dissipation of internal power heating components.
- Side wall reserved independent AC wiring terminal small window with removable plastic dust baffle to block foreign dust falling into internal wiring terminal space when unused.
- Internal PCB fixed with high-temperature insulating plastic support pillars to maintain fixed safe clearance between circuit board and metal shell to avoid accidental short-circuit caused by metal debris falling.
8. Working Principle
- External site AC220V industrial power source connects module AC input terminal via shielded power cable; input AC signal first passes built-in EMI filter to eliminate grid clutter interference before entering rectifier and switching conversion circuit.
- Internal high-frequency switching circuit converts alternating current into stable DC24V direct current after isolation transformation, then outputs to TMR chassis backplane power distribution bus via rear VME connector pins.
- When two 5501-381 modules work in parallel redundant state, onboard current-sharing circuit automatically distributes chassis total load current evenly between two power units; single faulty module exits output automatically while the other module bears full chassis load without DC bus voltage collapse.
- Four real-time detection circuits separately monitor input voltage state, internal power circuit working condition, core temperature and output voltage; corresponding LED lamp lights up immediately once any monitored parameter exceeds normal rated range to indicate specific fault category.
- Internal three-stage protection circuit activates instant shut-off of DC output when short-circuit, overcurrent or overtemperature abnormal condition occurs to prevent back-end chassis loaded control modules from overvoltage burnout damage.
- External dry-contact fault signal outputs switch state change synchronously along with internal fault triggering for transmitting abnormal alarm signal to upper-level DCS monitoring system to realize remote fault early warning.
9. Advantage Highlights
- Exclusive customized design for Woodward MicroNet TMR control chassis realizes zero dimensional and electrical compatibility error during VME slot plug-in assembly, eliminating non-original power adapter matching hidden danger.
- Full hot-swap function realizes single faulty power module online replacement without entire control system power outage, greatly improving uninterrupted operation reliability of power station core control equipment.
- Built-in multi-stage integrated protection circuit omits extra external overcurrent protection accessory configuration, simplifies cabinet internal power wiring layout and reduces peripheral fault points.
- Wide-temperature grade raw material selection enables stable continuous operation from -40℃ to +70℃ without additional cabinet forced cooling fan under standard industrial control cabinet environment.
- Dual-module parallel current-sharing redundant mode fully satisfies TMR triple redundant control system high-reliability power supply design requirement for critical power generation unit.
- Complete factory serial number traceability system guarantees spare part inventory accurate matching and after-sale replacement consistency for all on-site running equipment.
- Standard front-panel multi-indicator design shortens on-site fault positioning time and reduces maintenance difficulty during equipment daily inspection work.
10. Applicable Industries
- Thermal & Gas Power Generation Industry: Steam turbine, heavy-duty gas turbine, large diesel generator set MicroNet TMR control cabinet core redundant power supply configuration.
- Oil & Gas Industry: Offshore oil platform large centrifugal compressor control rack, natural gas pipeline pressurization unit TMR turbomachinery control system power matching.
- Marine Propulsion Industry: Large ocean-going cargo vessel main engine TMR governor control cabinet, marine auxiliary gas turbine control system power supply assembly complying with DNV-GL marine standard.
- Petrochemical Refining Industry: Refinery cracking furnace blower, large reciprocating compressor safety interlock TMR control cabinet internal power supply configuration.
- Hydropower Equipment Industry: Large hydro-turbine TMR governor control cabinet core power backup unit installation and application.
- Industrial Heavy Engine Industry: Large industrial gas engine and turbocharger test bench redundant control system dedicated power module matching.
11. Model Series Classification
- Base standard model: 5501-381 (Factory default standard AC220V input bare power module without attached external wiring harness)
- Derivative variant 1: 5501-381-C (PCB full conformal coating customized model for high-humidity coastal and chemical corrosive gas environment)
- Derivative variant 2: 5501-381-K (Complete set model with factory pre-terminated AC input power cable and terminal plug accessory)
- Derivative variant 3: 5501-381-110 (Custom modified AC110V input version for North America and Japan local industrial power grid specification)
12. Installation Requirements
- Cabinet pre-installation environment standard: Install inside IP43 and above sealed industrial control cabinet; keep installation slot over 120mm spacing away from cabinet internal high-power transformer and AC contactor strong magnetic field components.
- VME slot plug-in specification: Align module bottom guide rail with chassis slot inner track, push module horizontally along track until rear VME connector fully locks into backplane socket with audible locking sound; prohibit forced lateral prying during plugging to avoid connector pin bending deformation.
- AC power wiring rule: Use shielded three-core power cable for AC220V input wiring; cable shielding layer single-end connects cabinet PE protection ground bar with copper wire gauge ≥2.5mm².
- Pre-power-on inspection requirement: After module installation and wiring completion, use multimeter to confirm no short-circuit between AC input live line and ground terminal before switching on cabinet AC total power supply.
- Dual redundant installation regulation: When deploying two 5501-381 modules inside single TMR chassis, arrange two modules at non-adjacent slot positions to avoid mutual heat accumulation affecting heat dissipation efficiency.
- Post-install preheating specification: Power on module and maintain continuous 30min preheating period to stabilize internal switching circuit temperature before formal system commissioning and load test.
- Cabinet ventilation constraint: Keep chassis surrounding ventilation space unblocked without baffle or foreign object covering module upper and lower heat dissipation slots.
13. Usage Precautions
- Electrostatic protection regulation: Wear certified anti-static wristband reliably connected to cabinet PE ground bar when pulling out module or opening shell for internal component inspection; bare-hand direct contact with PCB circuit and gold-plated connector pins is strictly forbidden to prevent electrostatic breakdown internal power device.
- Live operation restriction: Prohibit live disassembly of module AC input wiring under powered running state; hot-swap replacement only allows pulling module out from VME slot after confirming front panel OK lamp is in normal bright state.
- Daily maintenance specification: Clean module surface accumulated dust every six months with dry compressed air at maximum 0.3MPa air pressure; avoid high-pressure air direct blowing to internal electrolytic capacitor solder joint area.
- Overload operation constraint: Strictly control single module continuous output current not exceeding rated 30A; prohibit long-term overloading running beyond rated output parameter range.
- Spare module storage standard: Store idle spare modules inside original factory anti-static shielding carton under 15℃~25℃ dry constant-temperature warehouse environment, far away from corrosive chemical reagent and high dust concentration space.
- Fault disposal criterion: Cut off corresponding AC input power supply immediately once abnormal overheating, burnt smell or frequent fault lamp flicker occurs during operation; unauthorized disassembly of module shell and modification of internal original circuit layout are prohibited, contact Woodward official after-sales engineer for professional maintenance.
- Long-term idle equipment management: If control cabinet stops running over 60 consecutive days, cut off all 5501-381 modules AC input power; place desiccant bags inside cabinet and fully close cabinet door to prevent internal PCB damp condensation corrosion.
Reviews