ABB BCU-02

Technical Specifications:
  • Designed to manage various types of boilers including gas, oil, and dual-fuel boilers.
  • Capable of handling multiple burner configurations and supports integration with external systems for comprehensive control and monitoring.
  • Equipped with advanced sensors for measuring temperature, pressure, and flow rates, ensuring precise control over boiler parameters.
  • Supports communication protocols such as Modbus, allowing seamless integration with building management systems (BMS) or other supervisory control systems.

ABB BDFC-01C Backplane Module

Technical Specifications

  • Current: 0 - 60A
  • Power: 220V
  • Working Temperature: It can work normally in a certain temperature range, but the specific value is not clearly stated in the existing information.
  • Installation Method: It can be installed on - site, and the installation method is clamping connection.

ABB BSD0750

  • Rated Power: 750W
  • Input Voltage Range: 200 - 230VAC
  • Output Current: 4.8A
  • Peak Torque: 3.2 Nm
  • Speed Range: 0 - 6000 rpm
  • Position Accuracy: ±0.01°
  • Acceleration: 0 - 10000 rpm/s
  • Maximum Working Voltage: 690V AC
  • Rated Current: 750A

ABB CI522A 3BSE018283R1 Communication Interface Module

Technical Specifications

  • Basic Parameters
    • Type: Communication interface module.
    • Series: CI522A.
    • Weight: Approximately 0.2kg.
    • Installation method: DIN rail mounting or screw fixing.
  • Electrical Parameters
    • Input voltage: 24V DC ±20%.
    • Output voltage: 24V DC.
    • Maximum output current: 500mA.
    • Communication baud rate: Up to 1.5Mbps.
  • Environmental Parameters
    • Operating temperature range: -25°C to +70°C.
    • Storage temperature: -40°C to +85°C.
    • Relative humidity: 5% to 95% (non-condensing).
    • Protection level: IP20.

ABB CI534V02 3BSE010700R1 Profibus DP-V1 Communication Interface Module (for AC 800M DCS)

Technical Specifications

  • Communication Performance:
    • Protocol Support: Profibus DP-V1 (compliant with IEC 61158-3-1); backward compatible with Profibus DP-V0
    • Communication Rate: 9.6 kbps – 12 Mbps (auto-negotiation or manual configuration)
    • Maximum Nodes: Up to 124 Profibus DP slave devices per module
    • Cyclic Data Transfer: Supports real-time process data exchange (typical update time <1ms at 12 Mbps)
    • Acyclic Data Transfer: Supports FDL (Fieldbus Data Link) and DPV1 acyclic services (for device parameterization and diagnostics)
    • Bus Topology: Line topology (supports redundant bus configuration for high availability)
  • Electrical Parameters:
    • Power Supply: 24V DC (from AC 800M controller backplane); Power consumption: 3W (max)
    • Profibus DP Interface: 2 x Sub-D9 male connectors (for primary and redundant bus, if used)
    • Isolation: 500V AC galvanic isolation between Profibus bus and controller backplane

ABB CI627A 3BSE017457R1 Serial Communication Interface Module

Technical Specifications
  • Communication Specifications
    • Protocols Supported: RS-232, RS-422, RS-485 (full-duplex and half-duplex modes); compatible with Modbus RTU protocol
    • Serial Ports: 2 independent serial communication ports
    • Transmission Speed: 300 bit/s to 115200 bit/s (configurable via software)
    • Data Bits: 7 or 8 bits (selectable)
    • Parity Check: None, Even, Odd (configurable)
    • Stop Bits: 1 or 2 bits (selectable)
    • Flow Control: Hardware (RTS/CTS) and software (XON/XOFF) flow control supported
  • Power Specifications
    • Power Supply Voltage: 24 VDC (operating range: 20.4 VDC to 28.8 VDC)
    • Power Consumption: 2.5 W (typical value under normal operation)

ABB CI801 Communication Interface Module

Technical Specifications:
  • Communication Protocols:
    • PROFIBUS DP (from station mode) with automatic baud rate adaptation from 9.6 Kbps to 12 Mbps.
    • Supports PROFIBUS-DPV1 for enhanced functionality.
    • RS-485 interface compliant with PROFIBUS DP standards.
  • Power Supply:
    • Operating voltage: 24 V DC (typically supplied by the controller backplane).
    • Power consumption: ≤ 5 W.

ABB CI801 Profibus FCI S800 Interface

Technical Specifications
  • Product Type: Fieldbus communication interface module.
  • Installation Method: DIN rail mounting.
  • Dimensions: 58.5mm x 136mm x 85.6mm.
  • Net Weight: 0.3kg.
  • Power Supply: 24VDC.
  • Supported Communication Protocols: Profibus DP, Foundation Fieldbus H1, HART.
  • Number of Fieldbus Connections: 1.
  • Number of Supported I/O Channels: Up to 256.

ABB CI840A 3BSE041882R1 Profibus DP-V1 Communication Interface Module

Technical Specifications
  • Form Factor: 19-inch rack mount.
  • Dimensions: 135mm x 75mm x 90mm; or 127mm x 102mm x 178mm; or 96mm x 119mm x 54mm.
  • Net Weight: 0.34kg; or approximately 0.5kg; or 1kg.
  • Power Supply: 24VDC.
  • Power Consumption: 20W; or less than 5W.
  • Operating Temperature: -20°C to 70°C; or -40°C to 85°C.
  • Protection Class: IP20; or IP65.
  • Communication Protocol: Supports Profibus DP-V1 protocol; also compatible with standard bus protocols such as Modbus, DeviceNet, and CANopen.
  • Communication Interface: Profibus DP-V1 fieldbus interface, RS-485 interface; also supports RS232/422/485 serial ports, USB3.2/2.0, and HDMI high-definition display; equipped with dual Intel Gigabit Ethernet ports.

ABB CI854A PROFIBUS-DP/V1 Interface Module

Technical Specifications
  • Power Specifications
    • Voltage: 24V DC (some models support 220V AC)
    • Current: Maximum 250mA (some models support 5mA or 0.5A)
  • Communication Specifications
    • Protocols: PROFIBUS DP/V1, Modbus RTU, Modbus TCP, Ethernet, CAN, IEC 60870-5-101, etc.
    • Master or Slave: Master
    • Number of Channels: 2 PROFIBUS ports
    • Transmission Speed: 9.6 - 12000 kbit/s; PROFIBUS DP: Maximum 12 Mbps; CAN: Maximum 1 Mbps; Ethernet: Maximum 100 Mbps
    • Line Redundancy: Yes
    • Module Redundancy: Yes
    • Maximum Communication Distance: 100 meters
    • Number of Nodes: PROFIBUS DP: Maximum 31 nodes; CAN: Maximum 255 nodes; Ethernet: Maximum 254 nodes

ABB CI854AK01 3BSE030220R1

Technical Specifications
  • Physical Dimensions:
    • Depth: 127.5 mm
    • Height: 186 mm
    • Width: 59 mm
    • Weight: 0.59 kg
  • Communication Protocols: Supports Modbus, Profinet, Profibus DP/DP-V1, and FOUNDATION Fieldbus, enabling seamless integration with diverse industrial devices.
  • Tension Measurement: Utilizes incremental photoelectric encoders and M/T speed measurement for high-precision motor rotor speed feedback.
  • Environmental Compliance: Adheres to EU Directive 2011/65/EU (RoHS) and classified as small equipment (WEEE) for eco-friendly disposal.

ABB CI854AK01 3BSE030220R1 Communication Module

Technical Specifications

  • Compatibility: Exclusively designed for ABB AC 800M DCS; Integrates with ABB’s PROFINET IRT (Isochronous Real-Time) network architecture
  • Processor: 32-bit industrial-grade microprocessor with a clock speed of 500 MHz (optimized for real-time data processing)
  • Memory: 256 MB DDR3 SDRAM (for data buffering and protocol handling); 128 MB Flash memory (for firmware storage and configuration files)
  • Operating Voltage: 24 V DC (nominal); Voltage tolerance: 19.2 V DC – 28.8 V DC
  • Power Consumption: Typical 8 W, Maximum 12 W (under full communication load)
  • Operating Temperature: -25°C to +60°C (ambient temperature, suitable for harsh industrial environments)