Bently Nevada 19000-00-90-18-02 Universal Machinery Monitoring System
Technical Specifications
-
Measurement & Input Parameters
- Sensor inputs: 4 channels (supports 2-wire/3-wire accelerometers, velocity sensors, proximitor sensors)
- Temperature inputs: 4 channels (compatible with E, J, K, T-type thermocouples; 2-wire/3-wire RTDs)
- Frequency response: 0.5 Hz to 200 Hz
- ADC resolution: 24-bit
- Data acquisition: High-speed with advanced signal processing algorithms
-
Output Parameters
- Relay outputs: 6 configurable channels (programmable based on normal, alarm, danger states)
- Recorder outputs: 4 configurable 4–20 mA channels (transmits data for any variable from any channel)
- Buffer outputs: 1 dedicated channel per sensor input (direct signal transmission)
-
Electrical Parameters
- Operating voltage: 24 V DC; 100–240 V AC, 50/60 Hz
- Input voltage range: 18–32 V DC, 2.5 A
- Communication protocols: Ethernet/IP, Profinet, Modbus RTU, CAN, RS232/485
- Communication interfaces: Ethernet port, software-configurable RS232/485 serial port, USB
- Modbus gateway: Supports data transmission to Modbus clients (static variables, status, event logs, time/date)
Bently Nevada 18745-03 Universal Equipment Monitor
Technical Specifications
-
Measurement Parameters
- Proximitor measurement type: Static and dynamic distance, gap
- Proximitor range: 5 mm to 8 mm (core range); 0 mm to 10 mm (extended range)
- Proximitor accuracy: ±25 µm; ±1% of reading
- Vibration/velocity/position measurement: Supported via configurable sensor inputs
- Temperature measurement: Compatible with E, J, K, T-type thermocouples and 2-wire/3-wire RTDs
- Frequency response (monitor): 0.5 Hz to 200 Hz
- Output frequency (proximitor): 30 kHz
-
Electrical Parameters
- Operating voltage: 220 V
- Input channels: 4 sensor inputs (supports 2-wire/3-wire accelerometers, velocity sensors, proximitors); 4 temperature inputs
- Output channels: 6 relay outputs; 4 configurable 4–20 mA recorder outputs; 1 dedicated buffer output per sensor input
- ADC resolution: 24-bit
- Communication protocols: Ethernet/IP, Profinet, Modbus RTU, CAN, RS232/485
- Communication interfaces: Ethernet port, software-configurable RS232/485 serial port
Bently Nevada 9200-06-02-10-00 Two-Wire Seismo Probe Velocity Transducer
Technical Specifications
-
Measurement Parameters
- Measurement type: Absolute vibration velocity (relative to free space)
- Measurement range: 0.5 to 30,000 rpm
- Sensitivity: 20 mV/mm/s (500 mV/in/s) ±5% at 100 Hz (6,000 cpm)
- Accuracy: ±0.2% of full scale
- Resolution: 0.01 rpm
- Frequency response: 10 Hz (600 cpm) to 1 kHz (60,000 cpm), ±3 dB typical
-
Electrical Parameters
- Output type: Voltage output proportional to vibration velocity; optional 4–20 mA or 0–10 V
- Wiring configuration: Two-wire system (no external power required)
- Lead length: Up to 305 meters (1,000 feet) between transducer and monitoring system
- Compatibility with converters: Works with 9513 and 46687 velocity-displacement converters
Bently Nevada 13677-01 Industrial Signal Conditioning Module
Technical Specifications
-
-
Input Parameters
- Input type: Low-level analog signals (voltage, current, or resistance-based sensor inputs)
- Input channels: 4 differential or 8 single-ended input channels
- Input range: Configurable for ±5 VDC, ±10 VDC, 0–5 VDC, 4–20 mA, or 10–30 mA
- Input impedance: ≥ 100 kΩ for voltage inputs; ≤ 10 Ω for current inputs
- Common-mode rejection ratio (CMRR): ≥ 80 dB at 50/60 Hz (minimizes interference from common-mode signals)
-
Output Parameters
- Output type: Standardized analog output (4–20 mA DC or 0–10 VDC)
- Output accuracy: ±0.05% of full scale (at 25 °C ambient temperature)
- Output resolution: 16-bit (ensures precise signal representation)
- Output load capacity: Up to 500 Ω for 4–20 mA output; ≥ 10 kΩ for voltage output
-
Electrical Requirements
- Power supply: 24 VDC ±10% (compatible with standard industrial power systems)
- Power consumption: ≤ 2.0 W (low energy consumption for continuous operation)
- Reverse polarity protection: Integrated (prevents module damage from incorrect wiring)
- EMI/RFI immunity: Complies with IEC 61000-6-2 (industrial environment electromagnetic compatibility standards)
-
Bently Nevada 9200-06-01-10-00 Vibration Transmitter
Technical Specifications
-
Input Parameters
- Input type: Accepts signals from piezoelectric accelerometers or velocity sensors
- Input range: Configurable for acceleration (0–500 m/s²), velocity (0–50 mm/s), or displacement (0–1000 μm)
- Frequency response: 0.5 Hz to 10,000 Hz (covers most industrial rotating machinery needs)
- Input impedance: ≥ 10 MΩ (ensures minimal signal loss from sensors)
-
Output Parameters
- Output type: 4–20 mA DC current loop (standard industrial output)
- Output accuracy: ±0.1% of full scale (at 25 °C ambient temperature)
- Output load: Up to 750 Ω (compatible with most DCS/PLC input modules)
- Additional output: Optional relay output (for alarm triggering, based on configuration)
Bently Nevada 60M500-05-00 vbOnline Pro Condition Monitoring System
Technical Specifications
-
Electrical Parameters
- Minimum input power: 18 VDC
- Maximum input power: 36 VDC
- Maximum current: 1.7 A
- Maximum inrush current: 2.7 A (less than 5 ms)
- Dynamic range: 110 dB @ fs = 102.4 ksps
- Signal/noise ratio: 110 dB @ fs = 102.4 ksps
- A/D conversion: 24-bit sigma-delta
- Bandwidth: 0 to 40 kHz
- Output signal: 0-5 V
- Supported protocols: Bently Nevada proprietary protocol, Modicon Modbus, Modbus/TCP
- Communication interfaces: Ethernet TCP/IP, serial (RS 232/RS 422/RS 485)
Foxboro RH924YF
Technical Specifications
- Power Supply: 24 VDC
- Operating Temperature Range: -20°C to +70°C
- Input Power: 220 VAC
- Output Frequency: 50 Hz
- Communication Protocols Supported: Modbus RTU, CAN open, Ethernet/IP
- SIL Compliance: Certified for SIL 2
- Enclosure Type: IP65
- Environmental Rating: NEMA 12
- Dimensions: 210 mm x 40 mm x 60 mm
- Weight: 0.5 kg
- Number of Inputs/Outputs: 4/4
Foxboro P0973CN
Foxboro P0926GH
Technical Specifications
- Power Supply: 24 VDC (common)
- Input/Output Signal: For analog input, it can support 0 - 10 V or 4 - 20 mA analog signal input; for analog output, it can provide 0 - 10 V or 4 - 20 mA output signal.
- Accuracy: Input voltage accuracy can reach ±0.05% for analog input; output accuracy is ±0.5% for analog output.
- Repeatability: ±0.2% for analog output.
- Response Time: 10 ms for analog output.
- Operating Temperature Range: - 20℃ - 60℃ (varies according to different specifications).
- Dimensions: Approximately 100 mm x 65 mm x 30 mm or 127 mm × 127 mm × 50 mm (varies according to different specifications).
- Weight: About 0.4 kg - 0.5 kg (varies according to different specifications).
Foxboro P0917MG
Technical Specifications
- Power Supply: 24 VDC
- Power Consumption: 8.5 W to 10 W
- Input Voltage Range: - 10 V to + 10 V or - 20 mA to 20 mA
- Output Signal: 4 - 20 mA DC
- Accuracy: ±0.15% or ±0.25%
- Operating Temperature Range: 0°C to + 60°C
- Storage Temperature Range: - 40°C to + 85°C
- Humidity Range: 5% to 95% (non - condensing)
- Memory: 16 MB SDRAM and 32 MB Flash
- Dimensions: 35 mm x 25 mm x 15 mm
Foxboro P0916JY
Technical Specifications
- Power Supply: 24 VDC
- Power Consumption: 50 mA
- Input Voltage Range: 0 to 24 VDC
- Input Current: 2 mA
- Output Voltage Range: 0 to 24 VDC
- Output Current: 2 A
- Operating Temperature: - 40 to 70 °C
- Storage Temperature: - 40 to 85 °C
- Humidity: 0 to 95% RH, non - condensing
- Vibration: 5 g rms, 10 to 500 Hz
- Shock: 15 g, 11 ms half - sine
Foxboro P0916JS Compression Terminal Module
Technical Specifications
- Power Supply: 24V DC
- Input Signal: 4 - 20mA
- Output Signal: 0 - 10V
- Number of Input/Output Channels: 16 input channels, supporting NPN and PNP programming
- Communication Protocol: Modbus, HART, etc.
- Operating Temperature Range: - 40°C to + 70°C
- Storage Temperature Range: - 40°C to + 85°C
- Relative Humidity: 5% to 95%
- Protection Level: IP67
- Dimensions: 100x60x25 mm (3.94×2.36×0.98 inches)
- Weight: 0.25 kg (0.5 lb)