Bently Nevada 3500/32-A01-B01 4-Channel Relay Module (Full-Height Front Card)

Technical Specifications
Module format : full-height, single-slot, front plug-in
Relay channels : 4 × SPDT (Form C)
Contact rating : 5 A @ 24 Vdc / 120 Vac (resistive)
Maximum switching voltage : 250 Vac / 30 Vdc
Operate time : ≤ 10 ms (typical)
Isolation : 1 500 Vrms coil-to-contact & channel-to-ground
Power draw : 5 W max (24 Vdc from rack back-plane)
MTBF : >300 000 h @ 45 °C per MIL-HDBK-217F
Operating temperature : –40 °C to +85 °C
Storage temperature : –40 °C to +85 °C
Humidity : 5 % – 95 % RH non-condensing
Shock / vibration : 15 g ½-sine 11 ms; 2 g 5-500 Hz operational
Dimensions : 15.5 cm × 10.2 cm × 2.5 cm
Weight : 0.5 kg
Agency approvals : CE, UL/cUL Class I Div 2, ATEX/IECEx Zone 2, RoHS

Category:
Description
Functional Highlights
Independent alarm-drive logic – every relay can be programmed with AND/OR combinations of any monitor channel alarm (Warning / Danger / OK) or real-time value
Three output styles – bus relay, dedicated relay or independent relay to match different voting philosophies
Fail-safe capability – normally-energised or normally-de-energised contact state selectable; supports latching and non-latching modes
Hot-swap maintenance – module can be inserted or removed under power without disturbing rack operation or protection
On-board diagnostics – front LEDs (OK, TX/RX, CH ALARM) give instant visual feedback; detailed relay health, cycle count and contact wear data are reported over the rack Ethernet link
Sealed contacts – epoxy block protects against dust, moisture and corrosive atmospheres (Class G3)
Firmware flash – field-upgradeable through 3500 Rack Configuration Software in <3 min; rollback image stored for safety
TMR ready – certified for use in Triple Modular Redundant racks where 2-out-of-3 voting is required


Application Scenarios
– Steam & gas turbine TSI cabinets – energise emergency stop solenoids, lift trip oil or annunciate overspeed alarms
– Offshore platform centrifugal compressors – drive fire & gas deluge valves, start standby pumps or send shutdown signals to DCS
– LNG refrigeration trains – isolate motor feeders on high vibration or differential expansion alarms
– Ethylene hyper-compressors – combine radial-vibration and temperature alarms through AND logic to initiate rod-drop shutdown
– Cross-country pipeline pump stations – redundant relay pairs vote to trip motor starters on thrust-bearing failure
– Steel mill blast-furnace blowers – energise visual/audible stack lights for early warning of gear-tooth damage
– Wind-turbine test stands – switch brake calipers when tower vibration exceeds safe threshold
– Nuclear feed-water pumps – TMR relay set meets IEEE 338 requirements for safety-related actuation


Installation & Maintenance
The card plugs into any full-height front slot; rear-mounted Euro-style connectors accept field wiring.
Captive screws provide chassis earth bonding and vibration resistance.
Front LEDs give immediate status indication; relay cycle counters and contact wear estimators are accessible through System 1 or any Modbus client.
Replacement takes <1 min with no need to power-down the rack or re-configure monitor set-points.

Compatibility
Backward- and forward-compatible with every 3500 monitor (3500/40M, 3500/42M, 3500/44M, 3500/45, 3500/46M, 3500/50, 3500/60, 3500/62, 3500/70M, 3500/72M, 3500/77M, 3500/90, 3500/92, 3500/93) and with 3500/22M TDI or legacy 3500/20 RIM modules.
Supported by System 1 v6.5 onward and by third-party OPC UA, Modbus and DNP3 clients.

Ordering Reference
350032-A01-B01 – Standard 4-channel relay module, SPDT, conformal coat
350032-A01-B02 – As above plus isolated coil drive
350032-A02-B01 – TMR version for triple-redundant racks
350032-AXX-BXX – Full modular option table for contact material, firmware revision and hazardous-area certification
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Bently Nevada 3500/32-A01-B01 4-Channel Relay Module (Full-Height Front Card)”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.