KROHNE OPTISONIC6300

Product Name
OPTISONIC 6300 Clamp-On Ultrasonic Flowmeter
Product Introduction
Permanent clamp-on ultrasonic flowmeter for liquids in existing pipelines. Measures volumetric flow without cutting the pipe, interrupting process, or contacting the medium—ideal for retrofit metering and non-intrusive custody/utility measurement.
Category:
Description
Technical Specifications
Principle: Ultrasonic transit-time
Medium: liquids, conductive and non-conductive
Pipe Size: DN15–DN4000 / 0.5″–160″
Velocity Range: 0.1–20 m/s
Process Temperature: -40 to +200 °C
Pressure Limit: none from sensor; limited by pipe
Outputs: 4–20 mA, HART 7, Modbus, Foundation Fieldbus, Profibus PA/DP
Sensor Rail: stainless steel
Converter: field/wall mounted
Diagnostics: NAMUR NE107
Options: IP68 / NEMA 6P, thermal energy, hazardous area
Functional Features
No pipe cutting or shutdown
External stainless sensor rail
Dual-path / X-mode reliability
Thermal energy calculation
Low maintenance coupling system
Advanced flow diagnostics
Application Scenarios
Potable water
Cooling water
Demineralized water
Sanitary liquid lines
Power-plant water circuits
Chemical process liquids
Performance Parameters
Accuracy: configuration and calibration dependent
Repeatability: ultrasonic transit-time class
Empty Pipe Detection: diagnostics supported
Energy Measurement: flow × temperature option
Material / Structure
Stainless steel sensor rail
Ultrasonic transducers
Coupling pads / regrease system
Field-mounted converter housing
Shielded transducer cables
Working Principle
Ultrasonic pulses travel through the pipe wall and liquid. The downstream pulse travels faster and the upstream pulse slower. The meter evaluates transit-time difference, derives flow velocity, and calculates flow using pipe diameter and fluid properties.
Installation Requirements
Pipe must be full and acoustically transmissible
Clean pipe outer surface
Mount sensor rail at KROHNE spacing
Apply correct coupling medium/pads
Avoid severe scale, heavy lining or strong vibration
Ground and shield converter correctly
Usage Notes
Air/gas pockets degrade accuracy
Insulated/lined pipes need application check
Re-verify after pipe or process change
Do not measure in empty pipe
Follow EX and laser/ultrasonic safety docs
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “KROHNE OPTISONIC6300”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.