Eaton KW3400F

Product Name​
Eaton Series C KW frame-only molded-case breaker frame, KW3400F.
Product Introduction​
KW3400F is the frame-only version of the KW 400 A molded-case breaker. It includes the K-frame structure, operating mechanism and adjustable thermal-magnetic trip provision but is supplied without terminals, allowing distributors or panel builders to add specific terminal kits, lugs and accessories.
Category:
Description
Technical Specifications​
Rated current 400 A. Pole count 3. Voltage rating 600 V AC, 250 V DC. Breaking capacity 45 kAIC at 415 V AC for the listed frame-only configuration. Trip type adjustable thermal and adjustable magnetic. Frame type K-frame, Series C, world/standard version. Terminals none; frame only. Approximate dimensions 140 mm x 105 mm x 140 mm; approximate weight 4.2 kg depending on trip unit.
Function Features​
Adjustable thermal and magnetic thresholds provide customized overload and short-circuit protection. Terminal-free frame supports flexible lug selection for busbar, cable and panel integration. Compatible with Eaton Series C K-frame accessories and separate trip units where required.
Structure Characteristics​
Insulated molded case, three-pole contact stack, adjustable bimetal thermal element compartment, magnetic actuator compartment, arc chute channels and manual operating handle. Terminal mounting faces are left open for field-fitted pressure terminals or copper/aluminum connectors.
Working Principle​
Same thermal-magnetic operation as KW3400: bimetal deflection for overload, electromagnetic armature for instantaneous short-circuit release. The frame transmits trip motion to the contact arms and isolates live parts through the molded enclosure.
Installation Requirements​
Install by qualified electrical personnel. Fit approved Eaton terminal kits matching conductor type and torque values. Confirm trip unit calibration before energization. Verify frame mounting clearances, ventilation and barrier requirements in the enclosure. For systems above 415 V AC, confirm the complete breaker assembly breaking rating rather than the 415 V frame-only rating alone.
Usage Precautions​
Never energize as frame-only without properly installed terminals and trip unit. Do not exceed 600 V AC or 250 V DC. Confirm kAIC at the actual system voltage; 45 kAIC applies at 415 V AC for this frame-only listing. Periodically verify thermal and magnetic set points after heavy fault duty.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Eaton KW3400F”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.