Technical Specifications
-
Supply: 24 V DC, consumption 2.5 W
-
Inputs: 2 safety channels (S11-S12, S21-S22), single/dual channel, cross-short detection
-
Outputs: 3 NO safety contacts (13-14, 23-24, 33-34), 1 NC auxiliary (41-42), 1 semiconductor output
-
Contact rating: 6 A at 240 V AC AC-1, 6 A at 24 V DC DC-1, 5 A AC-15 at 230 V
-
Reset: manual / automatic / monitored manual via selector
-
Dimensions: 22.5 × 98 × 120 mm
-
Weight: 185 g
-
Housing: PC material, IP40 front/body, IP20 installed
-
Certifications: CE, CCC, UKCA, cULus, TÜV, KOSHA, EAC
-
Standards: EN ISO 13849-1, IEC 62061, EN 60947-5-1
Functional Features
-
Forced-guided contacts
-
LED for power, input 1, input 2, output, reset, fault
-
Plug-in screw terminals
-
DIN 35 mm rail mount
Application Scenarios
Any machine needing certified emergency stop disconnect: presses, CNC, robot fences, assembly lines.
Working Principle
Both input channels closed → internal relay energized → safety NO contacts close to enable contactor coil → any channel opening or cross-short removes relay energy and drops safety outputs.
Installation Requirements
A1/A2 to 24 V DC. Emergency stop NC contacts in series on S11-S12 and S21-S22. Safety contacts in series with main contactor coil. Keep yellow safety wires separated from power wiring.
Usage Notes
Do not permanently short S21-S22 in dual-channel mode. Reset must follow machine risk assessment. Flashing fault LED indicates internal failure, return for service.