Technical & Performance Parameters
- Effective Measuring Stroke: 0 mm ~ 50 mm linear travel (00031 short stroke specification)
- Output Signal Standard: 4 mA (0% stroke) to 20 mA (100% stroke) DC analog current
- Measurement Linear Accuracy: ±0.1% full stroke range
- Repeatability Error: ±0.05% full measuring stroke
- Operating Supply Voltage: 12 V DC ~ 30 V DC two-wire loop power supply
- Subsea Rated Hydrostatic Pressure: 10,000 psi maximum seawater external pressure
- Surface Platform Working Pressure: Atmospheric to 200 psi non-submerged operation
- Operating Temperature Range: -40 °C ~ +85 °C
- Storage Temperature Range: -50 °C ~ +90 °C
- Ingress Protection Grade: IP68 full subsea sealing, continuous immersion rated
- Internal Circuit Isolation Withstand Voltage: 1000 V AC between sensing element and output signal circuit
- Anti-Vibration Compliance Standard: IEC 60068-2-6 offshore marine vibration certification
- Standard Physical Dimensions: Transmitter body diameter 42 mm, overall assembly length 185 mm, mounting thread M30×2
- Net Assembly Weight: 1.35 kg
- Industry Certifications: ATEX, IECEx, ABS marine, API 6D, SIL 2 functional safety certification
Material Composition
- Outer pressure housing: Super duplex stainless steel UNS S32750, full passivation anti-salt corrosion treatment
- Internal linear sensing core: Titanium alloy magnetic floating plunger, non-contact wear-free design
- Signal conditioning circuit substrate: High-temperature FR4 multi-layer PCB with full marine-grade three-proof coating
- Sealing components: Dual-layer fluorosilicone O-rings, compatible with seawater, crude oil, and hydraulic control fluid
- Cable entry connector: Hastelloy C276 alloy explosion-proof marine cable gland
- Internal magnetic sensing chip: Industrial-grade hall effect sensor with wide temperature stability
- Mounting threaded sleeve: Hardened 316L stainless steel with anti-seize coating for offshore bolted installation
Structural Characteristics
- Fully sealed monoblock pressure vessel housing design, zero fluid leakage risk under full subsea high hydrostatic pressure
- Non-contact magnetic hall effect sensing architecture; no physical friction between plunger and internal sensor to eliminate mechanical wear
- Dual independent fluorosilicone sealing layers at cable gland and plunger penetration points to block seawater ingress
- Standard M30×2 external mounting thread for direct threaded installation into Cameron wellhead actuator cylinder end caps
- Integrated two-wire loop power circuit; only two-core shielded marine cable required for both power supply and position signal transmission
- Compact concentric layout of sensing plunger and circuit compartment to minimize overall assembly footprint on limited subsea tree installation space
- Built-in passive lightning surge protection circuit integrated inside the sealed housing for offshore platform lightning strike resistance
Working Principle
- Valve actuator mechanical linear travel drives the titanium magnetic plunger inside the transmitter’s pressure housing to perform synchronous linear displacement along the measuring stroke
- Internal hall effect sensor continuously detects real-time magnetic field intensity generated by the moving plunger, corresponding proportionally to physical stroke position
- On-board signal conditioning circuit eliminates marine electromagnetic noise, calibrates raw magnetic signals, and converts displacement data into standardized 4–20 mA analog current output
- Two-wire marine shielded cable delivers loop power (12–30 V DC) to the transmitter while transmitting the 4–20 mA position feedback signal back to surface DCS or subsea SCM control unit
- Internal isolation barrier electrically separates the subsea mechanical sensing assembly from surface-side control circuits to block ground potential difference interference across seawater media
- Embedded surge protection components absorb lightning-induced high voltage surges from offshore power and signal cables to prevent circuit burnout
- Real-time built-in self-test circuit monitors sensor signal loss and cable open-circuit faults; outputs fixed <2 mA under fault conditions to trigger upper system valve position alarm
Core Function Features
- Non-contact magnetic sensing structure with infinite mechanical service life, no sliding friction wear under millions of actuator stroke cycles
- IP68 full subsea sealing and 10,000 psi high-pressure rating compatible with deepwater subsea tree installation
- Ultra-precise linear measurement ±0.1% FS, supporting high-accuracy wellhead choke valve flow regulation closed-loop control
- Two-wire 4–20 mA loop-powered design reduces subsea cable quantity and subsea umbilical laying engineering cost
- Native SIL 2 functional safety certification, meeting oil & gas process safety instrument system (SIS) specifications
- Super duplex stainless steel housing delivers superior resistance to seawater chloride ion corrosion and crude oil chemical erosion
- Wide operating temperature range adapts to Arctic cold offshore platforms and tropical high-temperature shallow sea production facilities
- API 6D and ATEX/IECEx explosion-proof certifications for surface hazardous zone wellhead and subsea classified zone deployment
Advantage Highlights
- Cameron OEM original matching component, direct bolt-in replacement for all Cameron subsea tree and surface wellhead actuator assemblies without mechanical modification
- UNS S32750 super duplex material eliminates common offshore rust and pitting corrosion failures seen with 316L stainless steel transmitters
- 50 mm short measuring stroke (00031 variant) optimized for compact subsea gate and choke valve actuators with limited travel range
- Non-contact sensing removes routine mechanical lubrication maintenance requirements for remote subsea installations with no human access
- Integrated surge protection eliminates need for external lightning arrestors on offshore signal cables
- SIL 2 safety rating enables deployment in critical wellhead emergency shutdown (ESD) safety loops
- Compact threaded mounting design reduces subsea tree structural modification and simplifies ROV remote replacement operations
Applicable Industries
Deepwater & shallow water offshore oil and gas production, onshore high-pressure wellhead gathering stations, subsea manifold control systems, floating production storage and offloading (FPSO) valve monitoring, LNG marine terminal wellhead actuator feedback
Installation Requirements
- Screw the M30×2 threaded mounting sleeve fully into the Cameron actuator cylinder end cap; tighten to specified 85 N·m installation torque using calibrated marine torque wrench
- Apply certified nickel-based anti-seize compound evenly to all stainless steel threaded surfaces before installation to prevent saltwater thread seizure
- Connect marine two-core shielded signal cable to the Hastelloy cable gland; uniformly compress gland sealing ferrule to achieve full IP68 waterproof cable locking
- Ensure the transmitter magnetic plunger maintains full mechanical coupling with the actuator’s internal pushrod; zero free play between moving components
- Route signal cable separately from high-voltage hydraulic power cables with minimum 50 cm physical separation to avoid analog signal distortion
- For subsea deployment, conduct 12-hour external hydrostatic pressure testing at 12,000 psi after installation to verify IP68 sealing integrity before subsea lowering
- Calibrate 4 mA (0 mm stroke) and 20 mA (50 mm stroke) signal endpoints via surface DCS system post-installation before valve commissioning
Usage Precautions
- Do not disassemble the monoblock super duplex pressure housing; disassembly breaks factory IP68 sealing and high-pressure containment integrity, voiding subsea operational safety certification
- Strictly avoid over-travel mechanical impact exceeding the rated 50 mm measuring stroke; plunger collision permanently damages internal hall effect sensing chip
- Never use unshielded ordinary industrial cable for signal transmission; unshielded wiring causes severe marine electromagnetic signal drift and inaccurate valve position feedback
- Do not expose the Hastelloy cable gland threaded connector to direct crude oil or chemical solvent spray without protective covers; chemical erosion degrades fluorosilicone sealing rings
- Perform annual offshore visual inspection of cable gland sealing and housing surface passivation coating to detect early salt corrosion pitting
- If feedback signal locks below 2 mA, immediately inspect cable for subsea water ingress open-circuit faults before transmitter replacement
- Storage before installation must use desiccant-sealed moisture-proof packaging; avoid long-term exposure to coastal salt fog atmospheric environments
Reviews