Bently Nevada ANA-D3510-100-A1 120M8155-01

Product Brief Introduction

4-channel isolated analog output submodule for Bently Nevada 3510 rack-based vibration monitoring system, converts internal digital machinery vibration/position data to standard industrial 4–20mA analog signals for PLC/SCADA remote acquisition.
Category:
Description

Technical Specifications

  1. Analog Output Channels: 4 fully galvanically isolated channels
  2. Standard Output Signal: 4–20 mA DC per channel
  3. Isolation Voltage Rating: 2500 VAC channel-to-backplane isolation
  4. Output Resolution: 16-bit digital-to-analog conversion
  5. Full-Scale Calibration Range: User-programmable 0–100% machinery measurement span
  6. Backplane Communication Interface: Bently Nevada proprietary 3500 series rack bus
  7. Operating Temperature Range: 0°C to +60°C
  8. Maximum Load Resistance per Channel: 500 Ω
  9. Assembly Hardware Identifier: Fixed part suffix 120M8155-01 full mechanical assembly

Functional Features

  • Independent channel span and zero calibration via host 3510 rack configuration software
  • Fault detection for open circuit and short circuit on each analog output loop
  • Overload current limiting protection for all output terminals
  • Channel status digital diagnostic flag transmitted to rack main processor
  • Signal scaling mapping vibration, displacement, speed measurement to 4–20mA range

Structural Characteristics

  • Standard 3500 series single-width rack plug-in module form factor
  • Gold-plated edge connector for rack backplane bus communication
  • Rear screw terminal strip for field analog loop wiring
  • Integrated internal isolation transformers per output channel

Material Composition

  • Module housing: Flame-retardant black ABS industrial plastic
  • Backplane edge connector: Gold-plated beryllium copper contact pins
  • Isolation components: High withstand voltage epoxy encapsulated transformers
  • Circuit substrate: FR4 high-reliability industrial PCB

Working Principle

Receive digital machinery measurement data (shaft vibration, axial position, rotational speed) from 3510 rack main processor via backplane bus; internal 16-bit DAC converts digital value to proportional analog current; galvanic isolation blocks ground loop interference between monitoring rack and field control system; continuously monitor loop impedance, trigger diagnostic fault flag upon wire break or short circuit; limit output current automatically to protect DAC circuit under overload conditions.

Advantage Highlights

  • High isolation voltage eliminates ground loop signal distortion in multi-system interconnection
  • Independent channel configuration without cross-channel signal crosstalk
  • Direct plug-and-play compatibility with all 3510 rack mainframes
  • Built-in loop fault diagnostics reduce field troubleshooting labor cost
  • Standard 4–20mA industry signal compatible with all mainstream industrial PLC hardware

Applicable Industries

Oil refinery rotating machinery monitoring, gas turbine power plants, steam turbine condition monitoring, petrochemical compressor stations, mining heavy rotating equipment, pulp & paper mill rotating asset protection

Installation Requirements

  1. Insert module into vacant single-width slot of 3510 series rack, lock side retention clips fully
  2. Route analog output wiring with shielded twisted pair cable, separate from high-voltage power cables
  3. Maintain rack cabinet ambient temperature below +60°C with cabinet ventilation fans
  4. Set maximum loop resistance under 500 Ω for each 4–20mA channel
  5. Complete channel scaling configuration via Bently Nevada System 1 software post-installation

Usage Precautions

  • Do not connect AC voltage signals to analog output field terminals; permanent circuit damage occurs
  • Avoid mounting rack in areas with continuous oil mist or conductive process dust
  • Perform full channel zero/span calibration after every field wiring modification
  • Do not hot-swap module while 3510 rack main power remains energized
  • Ground cable shield single-ended at PLC receiver side only to avoid dual ground loops
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Bently Nevada ANA-D3510-100-A1 120M8155-01”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.