  • Product Overview: Dedicated operator interface keypad for GE EX2100 excitation control systems, enabling direct command input, parameter adjustment, and real-time status monitoring. Features a 12-button keypad with 16-character alphanumeric display, function keys for excitation-specific tasks, and field-replaceable hot-swap capability. Installs as a front-panel HMI in EX2100 cabinets; communicates via system backplane to exchange data with the excitation controller. Powers from 24 VDC system bus, operates in -40°C–70°C environments, and supports hot-swap without system shutdown.
  • Technical Specifications – Input Power: 24 VDC (nominal), 21.6–26.4 VDC range; 0.5A maximum current draw
Category:
Description
  • Technical Specifications – Display: 16-character alphanumeric LCD; 7-segment + special characters for status/values
  • Technical Specifications – Keypad Layout: 12 keys (0-9, Enter, Clear); 4 dedicated function keys (Setpoint, Adjust, Status, Reset)
  • Technical Specifications – Communication: Backplane interface to EX2100 controller; 19.2 kbps baud rate; cyclic data refresh 100ms
  • Technical Specifications – Hot-Swap: Field-replaceable without powering down EX2100 system
  • Technical Specifications – Physical: 152mm × 76mm × 25mm; panel-mount bezel; 1kg weight; front-panel sealing IP65
  • Technical Specifications – Environmental: Operating -40°C–70°C; storage -55°C–85°C; 5%–95% non-condensing humidity
  • Technical Specifications – Certifications: CE, UL 508, IEC 61010-1 compliant; vibration/shock IEC 60068-2-6/2-27

  • Functional Features – Excitation-Specific Function Keys: Direct access to set excitation level, adjust field voltage, view system status, reset alarms
  • Functional Features – Alphanumeric Data Entry: 16-character display shows parameters, setpoints, alarms, and diagnostic codes
  • Functional Features – Hot-Swap Replacement: Removes/replaces without system shutdown; maintains controller operation during swap
  • Functional Features – Backplane Communication: Real-time data exchange with EX2100 controller for command execution and status updates
  • Functional Features – Status Indicators: Display shows “FIELD OK”, “ALARM”, “SETPOINT ACTIVE”, “SYSTEM READY” via special characters
  • Functional Features – Error Logging: Stores last 10 alarm codes with timestamps; accessible via keypad
  • Functional Features – Password Protection: 4-digit password locks critical operations (setpoint changes, manual control)
  • Functional Features – Wide Temperature Range: -40°C–70°C operation for outdoor/harsh industrial sites

  • Application Scenarios – EX2100 Excitation Systems: Primary HMI for EX2100 excitation controllers in power plants, industrial generators, and renewable energy systems
  • Application Scenarios – Power Generation: Turbine/generator excitation control rooms; adjusts field current to maintain grid voltage stability
  • Application Scenarios – Industrial Power: On-site control of backup generators, cogeneration systems, and UPS excitation units
  • Application Scenarios – Hydro/Nuclear Power: Excitation control for synchronous generators in hydropower and nuclear facilities
  • Application Scenarios – Remote Operation: Enables local parameter tuning and alarm response where SCADA is unavailable
  • Application Scenarios – Maintenance & Troubleshooting: Rapid access to diagnostic data, alarm logs, and parameter verification during service
  • Application Scenarios – Retrofit Projects: Upgrades legacy excitation system HMIs to EX2100-compatible keypad interface
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE IC752SPL013-BA”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.