ICS Triplex T8451 Trusted TMR 24 VDC 40‑Channel Digital Output Module

Technical Specifications

  1. Mechanical Specifications
    • Form Factor: Trusted chassis‑mounted module (fits T8100 controller/T8300 expander chassis slots)
    • Dimensions (H×W×D): 241 mm × 51 mm × 181 mm (9.5 in × 2.0 in × 7.1 in)
    • Weight: 1.13 kg (2.5 lb)
    • Front Panel: 40 channel status LEDs (green = active), 5 group power LEDs, power LED (green), fault LED (red), hot swap release lever
    • Mounting: Tool‑less insertion into Trusted chassis
    • Material: Industrial‑grade PCB with conformal coating; metal shielded enclosure for EMC compliance
    • Connectors: 96‑way C‑type backplane connector; dual redundant 24 VDC backplane power inputs (diode‑ORed)
    • Hot Swap: SmartSlot technology (Companion Slot or shared spare compatible)
  2. Electrical Specifications
    • Output Type: 40 independent 24 VDC sinking/sourcing outputs (configurable per channel)
    • Output Voltage: 18–32 VDC (operational); 0–32 VDC (measurement); -1 to 40 VDC (max withstand)
    • Output Current: 2 A continuous per channel; 8 A maximum per power group; 50 mA minimum on‑state load
    • Power Supply: 20–32 VDC redundant backplane supply (24 VDC nominal); 24 W maximum system power
    • Protection: Electronic latching short‑circuit protection; overcurrent/overvoltage protection per channel
    • Isolation: 2500 VDC galvanic between channels, backplane, and field power groups
    • Response Time: 0.5 ms output turn‑on/off delay; 0.5 ms sample update time
    • Leakage Current: < 10 µA (off‑state); On‑state Resistance: 0.6 Ω; Off‑state Resistance: 33 MΩ
Category:
Description
  1. Environmental Specifications
    • Operating Temperature: -40°C to +70°C
    • Storage Temperature: -40°C to +85°C
    • Relative Humidity: 5%–95% (non‑condensing)
    • Shock Resistance: 30 g, 11 ms duration (per IEC 60068‑2‑27)
    • Vibration Resistance: 5 g, 10–150 Hz (per IEC 60068‑2‑6)
    • EMI/EMC Compliance: EN 61000‑6‑2 (immunity), EN 61000‑6‑4 (emissions); CE, UL certified
    • Hazardous Area Certifications: ATEX II 2G Ex ia IIC T4 Ga; IECEx IECEx Ex ia IIC T4 Ga
  2. Safety & Compliance
    • Safety Certification: TÜV Certified IEC 61508 SIL 3; UL 61010‑1; CSA C22.2 No. 61010‑1; CE marked
    • Fault Tolerance: Fully triplicated TMR with 2oo3 voting; no single point of failure
    • Mean Time Between Failures (MTBF): 1,100,000 hours (per Telcordia SR‑332, 25°C)
    • Voting Logic: 2oo3 majority voting for output drive signals; automatic fault masking
    • Safety State: Configurable fail‑safe state (de‑energized or energized) per channel
    • Diagnostics: Continuous line monitoring for open/short circuits; stuck output detection; power group fault alerts

Functional Features

  1. 40 TMR Output Channels: High‑density 24 VDC outputs for large‑scale SIS actuation.
  2. 5 Independent Power Groups: Isolates 8 channels per group to prevent cross‑group fault propagation.
  3. TMR 2oo3 Voting: Eliminates single points of failure via triplicated drive circuits and majority voting.
  4. 2500 VDC Isolation: Protects backplane and channels from field transients/ground loops.
  5. SmartSlot Hot Swap: Module replacement without system shutdown for minimal downtime.
  6. 0.5 ms Update Time: Rapid output response for time‑critical safety shutdowns.
  7. 1 ms SOE Reporting: Captures output state changes for audit trails and root‑cause analysis.
  8. Electronic Short‑Circuit Protection: Latching protection per channel; no external fuses needed.
  9. Line Monitoring: Real‑time open/short circuit detection for field wiring faults.
  10. Redundant Backplane Power: 20–32 VDC diode‑ORed supply for power fault immunity.
  11. Configurable Fail‑Safe States: Per‑channel safe state (de‑energized/energized) for flexibility.
  12. Hazardous Area Ready: ATEX/IECEx certifications for explosive atmosphere deployment.
  13. Front‑Panel Diagnostics: Channel/group/power/fault LEDs enable rapid troubleshooting.
  14. Wide Temperature Range: Operates from -40°C to +70°C for extreme industrial conditions.
  15. 50 mA Minimum Load: Compatible with low‑current field devices (solenoids, small contactors).

Application Scenarios

  1. Oil & Gas ESD Systems: Drives 40 ESD valves and shutdown contactors in zone 1 hazardous areas, with TMR voting for fault tolerance and 0.5 ms response for rapid isolation.
  2. Chemical Plant Batch Control: Controls 40 process valves and heater contactors, using 5 power groups to isolate reaction zones and prevent cross‑process faults.
  3. Power Generation Turbine Trip: Triggers 40 turbine lube oil valves and emergency stop contactors, with 1 ms SOE for post‑trip root‑cause analysis.
  4. Marine Offshore Platforms: Operates 40 fire & gas alarms and lifeboat release mechanisms, with isolation to protect against saltwater‑induced ground loops.
  5. Mining Conveyor Safety: Controls 40 conveyor emergency stops and brake contactors, with hot swap for remote maintenance in dusty, humid mines.
  6. Pharmaceutical GMP Processes: Drives 40 cleanroom door interlocks and sterilization cycle valves, ensuring fail‑safe shutdown and compliance with FDA audit requirements.

Additional Information

  • Origin: United States
  • Warranty: 12‑month warranty for new original units; extended warranties via Rockwell Automation service contracts
  • Compatibility: Trusted T8100 controller chassis, T8300 expander chassis, T8311 expander interface modules
  • Installation: Tool‑less insertion into Trusted chassis; wire field devices to backplane connector; connect redundant 24 VDC backplane power
  • Maintenance: Hot swap for replacement; inspect LEDs for channel/group status; no periodic calibration required (electronic protection self‑resets)
  • Accessories: Trusted system software, field power distribution harnesses, backplane connector adapters, line monitoring test tools
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ICS Triplex T8451 Trusted TMR 24 VDC 40‑Channel Digital Output Module”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.