Woodward PEAK200-HVAC 8200-1501

Technical Specifications:

  • Model Number: 8200-1501
  • Controller Type: Digital microprocessor-based HVAC controller
  • Supply Voltage: 24 V AC ± 10%, 50/60 Hz
  • Power Consumption: Less than 15 VA
  • Operating Temperature: 0°C to +50°C
  • Storage Temperature: -25°C to +70°C
  • Humidity Range: 5% to 95% relative humidity, non-condensing
Category:
Description
  • Display: Integrated backlit LCD with local user interface for setup and monitoring
  • Input Types:
    • Analog: 0–10 V DC, 4–20 mA, RTD (Pt1000), resistive sensors
    • Digital: Dry contact inputs for status monitoring
  • Output Types:
    • Analog: 0–10 V DC or 4–20 mA for modulating valves, dampers, VFDs
    • Digital: Relay outputs (SPDT) for fan control, alarms, staging
  • Communication Interfaces: BACnet MS/TP, Modbus RTU, optional BACnet IP
  • Control Algorithms: PID, cascaded PID, floating control, logic sequencing
  • Memory: Non-volatile memory for program and setpoint retention
  • Mounting: DIN rail or panel mount
  • Enclosure Rating: IP20 (for indoor use)
  • Certifications: CE, UL Listed (File No. E126367), RoHS compliant

Functional Features:

  • Multi-Stage Control: Supports staging of heating and cooling equipment for improved energy efficiency
  • Economizer Logic: Built-in dry bulb and enthalpy-based economizer control for free cooling
  • Demand Controlled Ventilation (DCV): Integrates with CO₂ sensors to modulate fresh air based on occupancy
  • Time Scheduling: Onboard calendar and time clock for automatic occupancy-based operation
  • Alarm Management: Comprehensive alarm logging with time-stamped events and relay outputs
  • Auto-Tuning: Self-optimizing PID tuning for stable and responsive control
  • Graphical Programming: User-friendly configuration via local interface or PC software (e.g., PEAK Express)
  • Interoperability: Native BACnet support enables seamless integration into building automation systems (BAS)

Applications:

  • Commercial Buildings: Air handling units (AHUs), rooftop units (RTUs), and fan coil units in offices, schools, and retail spaces
  • Healthcare Facilities: Critical environment control in hospitals and laboratories requiring stable temperature and air quality
  • Data Centers: Precision control of cooling systems to maintain optimal operating temperatures
  • Industrial HVAC: Climate control in manufacturing plants, clean rooms, and process areas
  • Transportation Hubs: Environmental management in airports, train stations, and terminals
  • Energy Management Systems: Integration into central energy dashboards for monitoring and optimization
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Woodward PEAK200-HVAC 8200-1501”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.