GE 516TX 336A4940DNP516TX — Industrial Ethernet Switch (N-Tron 516TX Series)
The GE 516TX 336A4940DNP516TX (also referred to as the N-TRON 516TX-A Industrial Ethernet Switch) is a high-reliability networking device designed for mission-critical industrial environments. Part of GE's N-TRON series, this switch delivers robust connectivity and advanced management features for industrial automation systems.
GE Multilin 369-H1-R-M-F-E-H-E – Motor Management Relay
The GE 369-HI-R-M-F-E-H-E (also referred to as the Multilin 369 Motor Management Relay) is a high-performance industrial device designed for advanced motor protection, monitoring, and control in mission-critical applications. As part of GE’s Multilin product line, it combines robust hardware with programmable logic to ensure reliability in harsh environments.
GE IS215UCVEH2AE
The GE IS215UCVEH2AE is a VMEbus-based controller card designed for mission-critical industrial control systems, particularly within GE's Mark VI Speedtronic Turbine Control System. It serves as the central processing unit (CPU) for managing real-time operations in gas and steam turbines, ensuring precise control and monitoring of rotational speed, load, and safety parameters.
FOXBORO FCP270
The FOXBORO FCP270 (Field Control Processor 270) is a distributed, fault-tolerant controller designed for industrial process automation. As part of the I/A Series Distributed Control System (DCS) by Foxboro (now Schneider Electric), it executes real-time control logic, data acquisition, and alarm management in harsh environments.
FOXBORO A2H124-24FX Industrial Managed Switch
The FOXBORO A2H124-24FX (also referred to as the Enterasys A2H124-24FX) is a Layer 2 managed Ethernet switch designed for industrial and enterprise networks. Manufactured by Enterasys Networks (now part of Extreme Networks), this switch combines high-performance connectivity with robust security and scalability.
EMERSON A6370D – Programmable Controller / Overspeed Protection Monitor
COMPRESSOR IOC-555-D
The IOC-555-D is a simplex I/O communication card designed by Compressor Controls Corporation (CCC) for industrial automation systems, particularly in compressor and turbine control applications. While the term "COMPRESSOR IOC-555-D" may imply a standalone compressor, the IOC-555-D is actually a critical component within compressor control systems
Bently Nevada 3500/15 127610-01 – High-Reliability AC Power Supply Module
Technical Specifications
- Input Parameters:
- Voltage Range: 100–240 VAC (50/60 Hz) with wide compatibility for global power systems .
- Input Current: ≤2 A at full load (24 VDC, 5 A output) .
- Efficiency: ≥94% under typical load conditions, minimizing energy loss .
- Output Parameters:
- Voltage: 24 VDC with ±1% regulation to ensure stable power delivery .
- Maximum Current: 5 A continuous, supporting up to 14 monitoring modules in a 3500/05 rack .
- Ripple Noise: <100 mV peak-to-peak for sensitive industrial electronics .
Bently Nevada 350005
Bently Nevada 190065A-00-00-01-00-00 – General-Purpose Equipment Monitor
Technical Specifications
- Input Capabilities:
- Transducer Inputs: Four configurable channels supporting 2-wire or 3-wire accelerometers, velocity sensors, or proximity probes for vibration, position, or speed measurements .
- Temperature Inputs: Four channels supporting Type E, J, K, and T thermocouples, as well as 2-wire or 3-wire RTDs for thermal monitoring .
- Signal Conditioning: 24-bit ADC conversion ensures high-resolution data acquisition with ±0.1% full-scale accuracy .
ABB REF615C_E HCFDACADABC2BAN11E – Comprehensive Feeder Protection and Control Relay
The ABB REF615C_E is a high-performance feeder protection and control relay designed for medium-voltage (MV) distribution systems, combining advanced protection, automation, and communication capabilities. Below is a detailed overview based on verified technical documentation and industrial application data:
Technical Specifications
- Voltage Range:
- Primary Voltage: 10–35 kV (compatible with standard MV networks) .
- Secondary Voltage Input: 100 V (via voltage transformers) or direct sensor inputs (346–2339 mV for voltage dividers) .