ProSoft AN-X2-AB-DHRIO EtherNet

  • Technical Specifications
    • Power Supply Parameters
      • The typical power consumption is 200mA at 12V DC or 100mA at 24V DC, with a maximum power consumption of 2.4W. It adapts to the common low - voltage DC power supply environment in industrial sites and has low overall energy consumption.
    • Communication Parameters
      • It is equipped with one RJ45 10/100 Mbps Ethernet port and one DH+/Remote I/O port. It supports DH+, Remote I/O and EtherNet/IP protocols and now supports DH+ migrations on SLC networks.
      • It supports all DH+ and Remote I/O baud rates, which are 57.6k baud, 115.2k baud and 230.4k baud, and Remote I/O addressing ranges from 0 to 76 octal.
    • Environmental and Physical Parameters
      • The operating temperature ranges from 0°C to 50°C, and the storage temperature ranges from -40°C to 85°C. It can withstand extreme temperature changes in both indoor and outdoor industrial environments.
      • The relative humidity tolerance is 5% to 95% non - condensing. Its dimensions are 107mm x 126mm x 34mm excluding connectors, and it weighs approximately 310 grams. It supports DIN rail mounting for convenient integration into industrial control cabinets.

ProSoft MVI56-MDA4 MDA Scientific CM4 Gas Analyzer Master Module

Technical Specifications
  • Mechanical and Backplane Specifications
    • It is compatible with the 1756 backplane, adopts a single - slot design, and can be installed in both local and remote racks of ControlLogix chassis. It is recognized as a standard input and output module by the ControlLogix system and can access the processor memory smoothly.
  • Electrical Parameters
    • The input voltage ranges from 110V AC to 240V AC, and the operating frequency is 50Hz or 60Hz. The maximum power consumption does not exceed 5W, which shows low energy consumption and has little impact on the overall power load of the industrial control system.
  • Communication and Measurement Parameters
    • It supports Modbus RTU and Modbus ASCII communication protocols, is equipped with two RS - 232 communication ports for connecting to CM4 gas analyzers, and an RJ45 serial port for configuration operations.
    • The sampling rate can reach up to 10Hz. For common gases, the measurement range includes 0 - 25% volume for oxygen and 0 - 20000 ppm for carbon monoxide, with a measurement accuracy of ±0.5%.

ProSoft MVI56-MNETR Modbus TCP

  • Technical Specifications
    • Mechanical and Power Parameters
      • It adopts a single-slot design compatible with the Controllogix 1756 backplane, enabling easy installation into Controllogix chassis without occupying excessive space.
      • The backplane current load reaches 800 mA under 5 VDC and 3 mA under 24 VDC, matching the power supply requirements of Controllogix systems for stable operation.
    • Communication Parameters
      • It is equipped with a 10/100 Mbps Ethernet interface with auto-crossover detection, using an RJ45 connector suitable for Cat5 cables, and it supports Ethernet/IP pass-through communication.
      • It supports storage and transfer of up to 5000 16-bit registers with the Controllogix processor through block transfer or side-connect interface. Client parameters are configurable, including a minimum response delay ranging from 0 to 65535 milliseconds, and it also supports floating-point data types.
    • Environmental and Display Parameters
      • The operating temperature ranges from 0 °C to 60 °C, and the storage temperature ranges from -40 °C to 85 °C. It can operate normally in 5% to 95% relative humidity environments without condensation.
      • It is equipped with a 4-character scrolling alphanumeric LED display that shows module version, IP address, application port settings and error information, along with LED indicators for module status, application status and error status.

ProSoft MVI56-PDPMV1 PROFIBUS DP-V1 Master Network Interface Module for ControlLogix

  • Technical Specifications
    • Power and Physical Parameters
      • It is compatible with the 1756 backplane and occupies a single slot. The backplane current load is 800 mA at 5.1 VDC and 3 mA at 24 VDC, matching standard ControlLogix chassis power supply configurations.
      • The operating temperature range is 0°C to 60°C, and the storage temperature range is -40°C to 85°C. It can operate normally in an environment with 5% to 95% relative humidity without condensation.
      • It resists 30g operational shock and 50g non-operational shock, and can withstand 5g vibration within the frequency range of 10Hz to 150Hz, adapting to harsh industrial site conditions.
    • Communication Parameters
      • It supports all standardized PROFIBUS baud rates, with the maximum baud rate reaching 12 Mbps, meeting the requirements of high-speed data transmission in industrial scenarios.
      • It can connect up to 125 slave devices and can access PROFIBUS PA slaves through DP/PA couplers or links. It also allows multiple master modules to be installed in a single rack to expand network capacity.
      • It is equipped with an RS-232 configuration port with an RJ45 interface, and comes with an RJ45 to DB-9 male cable for on-site configuration and debugging.
    • Software Compatibility Parameters
      • It works with ProSoft Configuration Builder software, supporting functions such as importing project-specific GSD files and automatic bus parameter calculation.
      • It uses ladder logic for data transfer between the module and the processor, and a sample ladder file with add-on instructions is provided to simplify the configuration process for users.
      • It supports communication with configuration software via Ethernet routing through Rockwell Automation Ethernet interfaces such as 1756-ENBT and 1756-EN2T.

ProSoft MVI56-PDPS PROFIBUS DP Slave Communication Module for ControlLogix

Technical Specifications
  • Mechanical and Power Parameters
    • It adopts a single-slot design compatible with the ControlLogix 1756 backplane, supporting installation in both local and remote ControlLogix racks.
    • The power consumption parameters match ControlLogix chassis requirements: 5 VDC backplane current draw is 800 mA, and 24 VDC current draw is 3 mA, ensuring stable operation without overloading the chassis power supply.
  • PROFIBUS DP Communication Parameters
    • It complies with PROFIBUS DP V0 and V1 standards, supporting baud rates ranging from 9.6 kbps to 12 Mbps for flexible network configuration.
    • The module supports up to 244 bytes of input data and 244 bytes of output data for cyclic communication. For acyclic communication, it supports PROFIBUS DP V1 services, including parameterization, diagnosis and alarm handling.
    • It is equipped with a standard DB9 male PROFIBUS DP connector, compatible with standard PROFIBUS DP cables and connectors, and supports PROFIBUS DP slave addressing from 0 to 125.

ProSoft MVI69-MNET Modbus TCP

  • Technical Specifications
    • Power and Mechanical Parameters
      • It has a maximum current load of 800 mA at 5 VDC power supply. It adopts a standard 1769 single-slot design and is compatible with the 1769 backplane, which can be smoothly installed into the corresponding CompactLogix chassis.
      • It is recognized as a standard input and output module by the CompactLogix system, enabling unobstructed access to processor memory for smooth data transfer between the processor and the module.
    • Communication Parameters
      • It is equipped with a 10/100 Base-T Ethernet-compatible interface. The server driver can support connections to up to five Modbus TCP/IP clients through service port 502 with standard MBAP messaging, and another five clients through Modbus RTU/ASCII on service port 2000.
      • The client driver can actively read and write data with Modbus TCP/IP-compatible devices, and a single client can support up to 100 commands that can be sent to one or multiple servers. All data mapping of the module starts from Modbus register 40001.
    • Compatibility Parameters
      • It is compatible with all CompactLogix and MicroLogix 1500 LRP controllers, but it cannot be used with 1769-QBFC1B, 1769-L16X and 1769-L18X models. It supports Enron, Daniels and other floating-point data types to meet diverse data processing needs.

ProSoft MVI94-GSC Flex I/O Generic Serial Communication Module

  • Technical Specifications
    • Mechanical and Power Parameters
      • It adopts DIN rail installation mode, with dimensions of 120mm x 80mm x 40mm and a weight of about 200g, featuring a compact structure that saves installation space.
      • The power supply range is 9 - 30V DC, meeting the power demand of most industrial on-site power supply systems, and its enclosure protection level reaches IP20.
      • The operating temperature range is -40°C to 85°C, which enables it to operate stably in extreme temperature environments such as cold workshops and high-temperature industrial sites.
    • Communication Parameters
      • It supports multiple communication protocols including RS-232, RS-422, RS-485, ASCII, Modbus RTU and Modbus TCP/IP, covering most serial communication needs in industrial fields.
      • The maximum baud rate can reach 115.2 kbps, and it supports flexible configuration of parameters such as data bits and stop bits to match different serial device communication requirements.
      • It is equipped with a single-slot interface that supports ASCII communication, and is built with a 4096-character data buffer to ensure the stability of data transmission and avoid data loss due to transmission delays.
    • Compatibility Parameters
      • It is fully compatible with Allen-Bradley ControlLogix and CompactLogix series PLCs, and can be perfectly integrated into the corresponding control system architectures.
      • It is compatible with various serial industrial devices such as bar code readers, scales, terminals and printers, without requiring additional adaptation accessories during connection.

ProSoft PLX31-EIP-SIE EtherNet/IP to Siemens Industrial Ethernet Gateway

Core Function

  • Protocol Conversion: Bridges EtherNet/IP (CIP, PCCC) and Siemens Industrial Ethernet protocols for seamless interoperability between Rockwell controllers and Siemens PACs .
  • Data Exchange: Supports high-speed bidirectional transfers of up to 10,000 16-bit registers, ideal for large-scale industrial data synchronization .

ProSoft PLX32-EIP-PND EtherNet/IP to PROFINET Gateway

Functional Features

    1. Bidirectional Data Integration
      • Seamless data mapping between EtherNet/IP™ and PROFINET® I/O controllers without ladder logic programming .
      • Supports 100 configurable commands per client for customized data reads/writes .
    2. High Reliability & Redundancy
      • Dual Ethernet ports enable redundant network topologies, eliminating single-point failures .
      • SD Card Slot: Stores configurations for rapid recovery or transfer between gateways .

ProSoft PLX32-EIP-SIE Industrial Ethernet Communication Gateway

Technical Specifications
  • Power and Physical Parameters
    • It operates on a 24 VDC power supply and has a power consumption of approximately 5W, which is compatible with standard industrial power supply systems.
    • Its dimensions are 118 mm x 85 mm x 75 mm, and it adopts a compact structural design that saves installation space. It can be flexibly installed in various industrial control cabinets.
    • It has an operating temperature range of -40°C to 85°C, which allows it to run stably in extreme temperature environments such as cold workshops and high-temperature processing areas. It also features strong environmental adaptability with protection against dust and moisture.
  • Communication Parameters
    • It is equipped with Ethernet RJ-45 interfaces, supporting 10/100 Mbps Ethernet transmission rates to meet the data transmission needs of most industrial scenarios.
    • It supports dual subnet capability, allowing each protocol to reside on separate Ethernet subnets, which enhances the flexibility of network configuration.
    • It is compatible with multiple protocols including EtherNet/IP, Siemens Industrial Ethernet and Modbus TCP/IP, and realizes smooth protocol conversion and data interaction between different networks.

ProSoft PTQ-PDPMV1 PROFIBUS DPV1 Master Network Interface Module for Quantum Processors

Technical Specifications
  • Power and Physical Parameters
    • It uses a 24VDC power supply and has a power consumption of 1.5W, which is compatible with standard industrial power supply configurations.
    • Its dimensions are 110 mm × 95 mm × 50 mm and weighs 0.5 kg. The compact size allows for flexible installation in industrial control cabinets.
    • It operates within a temperature range of -40°C to 85°C and can withstand a humidity range of 5% to 95% without condensation, adapting to harsh industrial environmental conditions.
  • Communication Parameters
    • It serves as a PROFIBUS DPV1 master interface and supports baud rates ranging from 9600 bps to 12 Mbps, with automatic baud rate detection for all valid PROFIBUS DPV1 rates.
    • It can connect up to 125 slave devices when using repeaters, and can also connect PROFIBUS PA slaves to the network through DP/PA couplers or links.
    • It requires Ethernet connectivity for normal operation, and uses UDP messaging to back up data in status registers between modules to determine switchover conditions.

ProSoft RLX2-IHNF-A 802.11abgn Fast Industrial Hotspot

  • Technical Specifications
    • Physical and Environmental Parameters
      • It adopts a die-cast aluminum-plastic housing and DIN rail mounting. Its dimensions are 14.8 cm × 11.8 cm × 3.8 cm, and it weighs 499 grams, which is compact and easy to install in control cabinets.
      • The operating temperature range is -40°C to 70°C, and it can withstand up to 100% relative humidity without condensation. It complies with IEC 60068 anti-shock and anti-vibration standards, resisting 20g three-axis shock and 5g vibration from 10Hz to 150Hz.
    • Power Parameters
      • It supports 10 - 24 VDC power supply and is compatible with the 802.3af PoE standard. It can be powered by a PoE injector, reducing wiring complexity.
      • Its power consumption is less than 8W for Series C and less than 9W for Series B, featuring low energy consumption and adapting to long-term continuous operation in industrial systems.
    • Communication Parameters
      • It supports multiple wireless standards such as 802.11a, 802.11g, 802.11n, 802.11h and 802.11i, and is equipped with 3 RP-SMA antenna connectors for MIMO technology.
      • The adjustable transmit power ranges from 17 dBm to 22 dBm, and the receiver sensitivity is as low as -92 dBm at low transmission rates, ensuring stable signal reception.
      • It is equipped with one 10/100/1000 Base-T shielded RJ45 Ethernet port and one RS232 DB9 female serial port, supporting direct communication conversion between Modbus TCP/IP and Modbus RTU.