TRICONEX CM3201 – Communication Module for Safety-Critical Systems

Technical Specifications:

  • Type: Communication Module
  • System Compatibility: Designed to work within the Tricon system architecture, supporting seamless integration with other Tricon components.
  • Communication Protocols: Supports various industry-standard communication protocols, facilitating connectivity with Distributed Control Systems (DCS), Supervisory Control and Data Acquisition (SCADA) systems, and other plant networks.

Triconex CM3201 Communication Module

Technical Specifications
  • Power Supply: 24 V DC (input voltage range: 18 V DC to 30 V DC)
  • Communication Interfaces: Ethernet (10 Mbps), RS-232, RS-485
  • Redundancy Design: Triple-modular redundant (TMR) architecture for fault tolerance
  • Isolation Voltage: 500 V DC
  • Operating Temperature Range: -40°C to 70°C
  • Dimensions: Approximately 22 cm × 16.9 cm × 4.4 cm
  • Weight: Around 5 kg
  • Certifications: TÜV-certified for SIL 3 applications (IEC 61508, IEC 61511)

Triconex DI3201 Digital Input Module

Technical Specifications
  • Processor: 32-bit dual-core safety CPU, 180 MHz clock speed
  • Channels: 32 digital input channels per module
  • Redundancy: Triple Modular Redundant (TMR) architecture for fault tolerance
  • Input Signal Range: Compatible with standard digital voltage levels (e.g., 24 V DC)
  • SOE Resolution: Supports Sequence of Events (SOE) with 1 ms timestamp accuracy
  • Communication: Integrated into Triconex TMR systems via backplane or fieldbus interfaces
  • Environmental: Operates in temperatures from -40°C to 70°C; IP20 protection rating
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2

Triconex DI3301 Digital Input Module

Technical Specifications
  • Input Channels: 32 independent digital input channels, each with isolated electronics for fault tolerance.
  • Input Voltage Range: 18–32 VDC (typically 24 VDC).
  • Input Current: Maximum 6 mA per channel.
  • Input Types: Supports dry contacts (e.g., limit switches) and wet contacts (e.g., relay outputs).
  • Channel Isolation: Each input channel is isolated from the system bus to prevent interference.
  • Redundancy: Triple Modular Redundant (TMR) architecture ensures continuous operation even if one channel fails.
  • Response Time: ≤ 5 ms (including filtering).
  • Diagnostics: Line monitoring, open-circuit detection, short-circuit detection, and self-diagnostics.
  • Operating Temperature: -20°C to +60°C.
  • Storage Temperature: -40°C to +85°C.
  • Humidity Range: 5%–95% RH (non-condensing).
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2.

TRICONEX DI3301 Digital Input Module

Technical Specifications
  • Input Channels: 32 independent digital input channels
  • Input Voltage Range: 18–32 VDC (typical 24 VDC)
  • Input Current: ≤6 mA per channel
  • Input Types: Dry contact or wet contact signals
  • Channel Isolation: Each input channel is isolated from the system bus
  • Redundancy Design: TMR (Triple Modular Redundant) input paths per channel
  • Response Time: ≤5 ms (including filtering)
  • Diagnostic Functions: Line monitoring, open-circuit detection, short-circuit detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Humidity Range: 5%–95% RH (non-condensing)
  • Weight: 1.42 kg
  • Mounting: Mechanically locked to prevent misinstallation
  • Certifications: SIL 3 (IEC 61508), TÜV Rheinland-certified

Triconex DO 3626X Digital Output Module

Technical Specifications:
  • Channels: Multiple digital output channels (specific count varies by configuration).
  • Output Type: Switch-type (ON/OFF) for discrete control.
  • Output Current: Supports up to 2A per channel (actual value may vary based on configuration).
  • Load Voltage: Compatible with 24V DC systems (other voltages may be supported depending on model).
  • Response Time: ≤2ms for rapid signal conversion.
  • Power Consumption: Optimized for low energy use, typically ≤5W.
  • Operating Temperature: -20°C to +70°C (industrial-grade).
  • Dimensions: Compact design for space-efficient installation (e.g., 160mm × 100mm × 25mm).
  • Weight: Approximately 2kg.
  • Certifications: Compliant with IEC 61508 (SIL 3), TÜV, and other industrial safety standards.

TRICONEX DO3201 Digital Output Module

Technical Specifications
  • Processor: 32-bit dual-core SIL3-rated safety CPU, 180 MHz clock speed
  • Channels: 32 digital output channels per module
  • Architecture: Triple Modular Redundant (TMR) for fault tolerance
  • Output Current: Single-channel maximum 2 A
  • Output Signal Range: Supports standard industrial voltage levels (e.g., 24 V DC)
  • SOE Resolution: Supports Sequence of Events (SOE) with 1 ms timestamp accuracy
  • Diagnostics: Real-time monitoring of channel status, including open-circuit, short-circuit, and overload fault detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2

TRICONEX DO3401 Digital Output Module

Technical Specifications
  • Output Channels: 32 digital output channels
  • Output Type: 24 VDC, low-level effective (Sink-type output)
  • Output Structure: Transistor output (NPN or PNP, depending on version)
  • Output Capacity: Maximum 0.5 A per channel
  • Output Voltage Range: 18–32 VDC (24 VDC recommended)
  • Channel Isolation: Each channel is optically isolated from the system bus
  • Response Time: ≤ 5 ms (channel delay)
  • Short-Circuit Protection: Channel-level short-circuit and overcurrent protection
  • Redundancy: Operates with Triconex's triple modular redundant (TMR) architecture for fault tolerance
  • Status Monitoring: Supports per-channel status diagnostics, failure monitoring, and LED status indicators
  • Module Identification: Supports automatic identification and configuration, with channel addresses assigned by the controller

TRICONEX DO3625A Digital Output Module

Technical Specifications
  • Channels: 8 digital output channels
  • Output Type: Switch-type outputs
  • Output Current: 2 A per channel
  • Load Voltage: 250 V AC/DC
  • Response Time: ≤ 2 ms
  • Power Consumption: ≤ 5 W
  • Dimensions: 160 mm x 100 mm x 25 mm
  • Redundancy: Triple Modular Redundant (TMR) design for enhanced fault tolerance
  • Safety Certification: Compliant with SIL 3 safety integrity level requirements

TRICONEX DO3626X Digital Output Module

Technical Specifications
  • Output Channels: Multiple digital output channels (exact count varies by configuration).
  • Output Voltage: 24 V DC (standard industrial voltage).
  • Output Current: Supports a range of current levels to drive various loads (e.g., 100–400 A in some configurations).
  • Redundancy: Triple Modular Redundant (TMR) architecture ensures fault tolerance, allowing continuous operation even if one channel fails.
  • Response Time: Fast response time for real-time control applications (≤ 5 ms in typical configurations).
  • Operating Temperature: -20°C to +60°C (industrial-grade temperature range).
  • Storage Temperature: -40°C to +85°C.
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2 and other international standards.

TRICONEX DO9662-810 Digital Output Module

Technical Specifications
  • Output Channels: 16 digital output channels
  • Output Voltage: 24 VDC
  • Output Current: Supports low-level effective (sink-type) outputs with a maximum of 0.5 A per channel
  • Channel Isolation: Each channel is optically isolated from the system bus to prevent interference and ensure fault tolerance
  • Response Time: Fast response time for real-time control applications (≤ 5 ms)
  • Redundancy: Operates within Triconex's triple modular redundant (TMR) architecture for enhanced fault tolerance
  • Status Monitoring: Supports per-channel diagnostics, including open-circuit and short-circuit detection
  • Operating Temperature: -20°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2 and other international standards

TRICONEX EM2281 Safety Controller Module

Technical Specifications
  • Redundancy Architecture: Triple Modular Redundant (TMR) for enhanced fault tolerance.
  • Input/Output Channels: Supports a variety of I/O configurations, including digital and analog inputs/outputs, depending on the specific model and configuration.
  • Communication Protocols: Modbus RTU/TCP, HART, and other industrial protocols for seamless integration with DCS and SCADA systems.
  • Input Voltage: 24 V DC.
  • Power Consumption: Approximately 20 W.
  • Operating Temperature Range: 0°C to +60°C.
  • Storage Temperature Range: -40°C to +85°C.
  • Protection Class: IP20.
  • Programming Software: TriStation 1131 for configuration and programming.
  • Certifications: Compliant with IEC 61508 SIL 3, FM, ATEX, and other international safety standards.