Triconex DI3301 Digital Input Module

Technical Specifications

  • Input Channels: 32 independent digital input channels, each with isolated electronics for fault tolerance.
  • Input Voltage Range: 18–32 VDC (typically 24 VDC).
  • Input Current: Maximum 6 mA per channel.
  • Input Types: Supports dry contacts (e.g., limit switches) and wet contacts (e.g., relay outputs).
  • Channel Isolation: Each input channel is isolated from the system bus to prevent interference.
  • Redundancy: Triple Modular Redundant (TMR) architecture ensures continuous operation even if one channel fails.
  • Response Time: ≤ 5 ms (including filtering).
  • Diagnostics: Line monitoring, open-circuit detection, short-circuit detection, and self-diagnostics.
  • Operating Temperature: -20°C to +60°C.
  • Storage Temperature: -40°C to +85°C.
  • Humidity Range: 5%–95% RH (non-condensing).
  • Certifications: TÜV-certified for SIL 3 applications; compliant with IEC 61131-2.
Category:
Description

Key Features

  • High Reliability: TMR design ensures fault tolerance, minimizing downtime in critical applications.
  • Precision Timing: Supports Sequence of Events (SOE) with 1 ms timestamp accuracy for forensic analysis.
  • Flexible Integration: Compatible with both local and remote I/O configurations, adapting to diverse plant architectures.
  • Real-Time Diagnostics: Continuously monitors channel status, including wire break detection and diagnostic alarms.
  • Hot Swapping: Modules can be replaced without powering down the system, reducing maintenance disruptions.
  • Cybersecurity: Built-in protection against unauthorized access and data tampering.

Application Scenarios

  • Process Industries: Oil and gas, petrochemical, and chemical plants for emergency shutdown (ESD) systems and fire & gas (F&G) detection.
  • Power Generation: Nuclear and thermal power stations requiring SIL 3-certified input modules for turbine control and safety systems.
  • Energy Sector: Offshore platforms, pipelines, and renewable energy installations where fault-tolerant data acquisition is critical.
  • Manufacturing: Automated production lines, robotics, and machine control systems demanding high-speed, reliable digital inputs.
  • Transportation: Railway signaling and traffic control systems relying on precise digital signal interpretation.

Operational Advantages

  • Enhanced Safety: SIL 3 certification guarantees compliance with global safety standards for high-risk applications.
  • Reduced Downtime: Fault-tolerant design minimizes unplanned shutdowns, improving overall system availability.
  • Scalability: Supports up to 118 I/O modules per system, accommodating growing automation needs.
  • Cost Efficiency: Low lifecycle costs due to extended module lifespan and simplified maintenance.
  • Future-Ready: Enables integration with Industry 4.0 technologies for digital transformation initiatives.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Triconex DI3301 Digital Input Module”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.