TRICONEX 2000361-001 Digital Output Module part of Triconex Tricon system

Technical Specifications

  • Brand: TRICONEX (a Schneider Electric brand)
  • Model: 2000361-001
  • Redundancy: Triple-modular redundant (TMR) design with three independent channels per output signal.
  • Output Type: Digital outputs (specific voltage/current ratings depend on system configuration).
  • Diagnostic Coverage: Full hardware and software diagnostics for each channel, including output feedback verification.
  • Communication: Integrated into the Triconex Tricon system via TriBus for real-time data exchange between modules.
  • Environmental: Designed for harsh industrial environments with high resistance to electromagnetic interference (EMI) and temperature extremes.
  • Certifications: Complies with international safety standards such as IEC 61508 (SIL 3), TÜV, and other industry-specific approvals.
Category:
Description

Key Features

  • Fault Tolerance: The TMR architecture ensures continuous operation even if one channel fails, with automatic failover to healthy channels.
  • Real-Time Diagnostics: Continuous monitoring of output states, feedback loops, and hardware health to detect and isolate faults instantly.
  • Hot Swapping: Modules can be replaced without shutting down the system, minimizing downtime during maintenance.
  • High Availability: Supports online testing and calibration of outputs without interrupting control processes.
  • Secure Design: Resistant to unauthorized access or tampering, ensuring data integrity and system safety.

Application Scenarios
The TRICONEX 2000361-001 is widely used in industries where safety and reliability are paramount, including:

  • Oil & Gas: Emergency shutdown (ESD) systems, fire and gas (F&G) detection, and burner management systems (BMS).
  • Petrochemical: High-integrity pressure protection systems (HIPPS) and turbine control and protection (TMC).
  • Power Generation: Boiler protection, nuclear plant safety systems, and renewable energy control.
  • Pharmaceutical: Critical process control for sterile manufacturing and hazardous material handling.
  • Other High-Risk Industries: Mining, pulp and paper, and water treatment facilities requiring SIL 3-certified safety systems.

System Compatibility
The 2000361-001 module is fully compatible with the Triconex Tricon system, which includes:

  • Tricon Controllers: Triple-redundant controllers with shared memory and synchronized execution.
  • Input/Output Modules: Analog and digital input/output modules for interfacing with field devices.
  • Communication Modules: Support for Modbus, Ethernet, and other industrial protocols.
  • Engineering Workstations: Configuration and monitoring software for system setup and diagnostics.

Why Choose TRICONEX 2000361-001?

  • Proven Reliability: Over 1 billion hours of fault-free operation recorded in Triconex systems.
  • Global Certifications: Meets stringent safety requirements for worldwide deployment.
  • Scalability: Modular design allows easy expansion as process demands grow.
  • Support: Backed by Schneider Electric’s global service network for technical assistance and spare parts.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “TRICONEX 2000361-001 Digital Output Module part of Triconex Tricon system”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.