ProSoft AN-X2-AB-DHRIO EtherNet

  • Technical Specifications
    • Power Supply Parameters
      • The typical power consumption is 200mA at 12V DC or 100mA at 24V DC, with a maximum power consumption of 2.4W. It adapts to the common low – voltage DC power supply environment in industrial sites and has low overall energy consumption.
    • Communication Parameters
      • It is equipped with one RJ45 10/100 Mbps Ethernet port and one DH+/Remote I/O port. It supports DH+, Remote I/O and EtherNet/IP protocols and now supports DH+ migrations on SLC networks.
      • It supports all DH+ and Remote I/O baud rates, which are 57.6k baud, 115.2k baud and 230.4k baud, and Remote I/O addressing ranges from 0 to 76 octal.
    • Environmental and Physical Parameters
      • The operating temperature ranges from 0°C to 50°C, and the storage temperature ranges from -40°C to 85°C. It can withstand extreme temperature changes in both indoor and outdoor industrial environments.
      • The relative humidity tolerance is 5% to 95% non – condensing. Its dimensions are 107mm x 126mm x 34mm excluding connectors, and it weighs approximately 310 grams. It supports DIN rail mounting for convenient integration into industrial control cabinets.
Category:
Description
  • Functional Features
    • Multi – mode Operation for Diverse Upgrade Needs
      • It has multiple operation modes. The Drive mode supports upgrading legacy Allen – Bradley drives on Remote I/O to new EtherNet/IP – enabled drives and can support up to 4 EtherNet/IP drives without changing PLC code. The HMI mode allows upgrading legacy PanelViews on Remote I/O or DH+ to Ethernet/IP – based PanelView Plus series HMIs and supports up to 8 PanelViews on the same network.
      • The Remote I/O Scanner mode supports replacing legacy Remote I/O PLCs with ControlLogix or CompactLogix PACs and can handle up to 32 racks of Remote I/O. The Flex I/O Scanner mode replaces obsolete 1794 – ASB adapters and supports up to 16 EtherNet/IP connections.
    • Convenient Configuration and Diagnostics
      • The built – in web server eliminates the need for complex dedicated configuration software. Maintenance personnel can complete configuration and parameter adjustment through a web browser, and easily view real – time diagnostic data to quickly identify connection failures or data transmission abnormalities.
      • The auto – configuration utility can automatically discover baud rates and map discrete I/O, which greatly reduces configuration errors and improves the efficiency of on – site commissioning.
    • High Compatibility and Replacement Capabilities
      • It is fully compatible with Allen – Bradley equipment such as PLC – 5, CompactLogix, ControlLogix, PowerFlex drives and PanelView HMIs. It supports all PowerFlex drives on EtherNet/IP and works smoothly with various mainstream Allen – Bradley devices.
      • It can directly replace multiple old ProSoft modules, which simplifies the supply chain management for enterprises and reduces the difficulty of spare part replacement during later maintenance.
    • Stable and Reliable Operation Performance
      • The optional conformal coating enhances its resistance to harsh environmental factors such as moisture and dust in industrial sites, ensuring stable operation in harsh working conditions.
      • When upgrading related equipment in different modes, most scenarios do not require modifying the existing PLC code, which avoids operational risks caused by code changes and ensures the stable operation of the original control logic.
  • Application Scenarios
    • Legacy Drive Upgrade in Manufacturing Plants
      • In automobile assembly, electronic component processing and other manufacturing workshops, it upgrades legacy Allen – Bradley Remote I/O – connected drives to EtherNet/IP – enabled PowerFlex drives. It maintains the original PLC control logic, ensures the continuous and stable operation of production lines such as assembly lines and conveyor belts, and improves the controllability and monitoring capabilities of the drives.
    • HMI Modernization in Industrial Control Rooms
      • In industrial control rooms equipped with Allen – Bradley PLC – 5 or SLC controllers, it upgrades old Remote I/O or DH+ – connected PanelView HMIs to PanelView Plus series HMIs that support EtherNet/IP. Operators can obtain clearer interface display and faster data response while retaining the original control system, enhancing operation efficiency.
    • PLC System Migration in Petrochemical Plants
      • In petrochemical production sites with long – running Allen – Bradley Remote I/O PLCs, it helps replace the legacy PLCs with ControlLogix or CompactLogix PACs. It retains the existing racks of I/O equipment, realizes the migration of control systems at a low cost, and ensures the smooth transmission of data such as pipeline pressure and material flow between new controllers and on – site I/O modules.
    • Flex I/O Adapter Replacement in Food Processing Plants
      • It replaces obsolete 1794 – ASB adapters in food processing lines, enabling PLCs on Remote I/O to connect and control 1794 – AENT EtherNet/IP Flex adapters. It ensures the stable operation of on – site detection and execution equipment such as temperature sensors and material conveying valves, and meets the strict requirements of the food industry for production continuity.
    • DH+ to EtherNet/IP Data Link in Power Plants
      • In power plants with Allen – Bradley legacy control systems, it acts as a bridge between DH+ networks and EtherNet/IP networks. It realizes data interaction between legacy generators, transformer monitoring modules and modern EtherNet/IP – based SCADA systems. It ensures that operational data such as power generation and equipment temperature are uploaded to the central monitoring platform in real time, facilitating centralized management and early fault warning.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ProSoft AN-X2-AB-DHRIO EtherNet”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.