ICS Triplex T9892 8‑Channel Duplex Digital Output Termination Assembly

Technical Specifications

  1. Mechanical Specifications
    • Form Factor: AADvance standard termination assembly (compatible with T9300 3‑slot backplanes)
    • Dimensions: 112 mm (width) × 70 mm (depth) × 123 mm (height) (4.41 in × 2.76 in × 4.84 in)
    • Weight: 1.0 kg (2.2 lb)
    • Mounting: Plug‑in to T9300 backplanes; tool‑free installation
    • Protection Rating: IP20 (dust and finger contact protection)
    • Housing Material: Powder‑coated metal alloy with flame‑retardant polymer insulators
    • Color: Black (matches AADvance controller chassis)
    • Connector Type: Locking screw‑type terminal blocks (2.5 mm² wire capacity)
    • Field Power Access: Front‑panel dedicated connectors for dual commoned field power inputs
Category:
Description
  1. Electrical Specifications
    • Nominal Output Compatibility: 24 VDC (via T9451 module); max switching current: 2 A per channel
    • Channel Configuration: 8 duplex isolated channels with dual commoned field wiring
    • Power Distribution: Dual‑redundant power buses (common A and common B) for duplex operation
    • Field Power Input: 24 VDC (18–32 VDC range); dual commoned connections for redundant field power
    • Backplane Power Input: 18–32 VDC
    • Backplane Current Draw: 120 mA (max)
    • Power Consumption: 2.8 W (max)
    • Heat Dissipation: 9.5 BTU/hour
    • Isolation: Channel‑to‑channel isolation: 500 VDC; channel‑to‑chassis isolation: 500 VDC
    • Common Bus Current Capacity: 10 A per common (common A and common B)
  2. Environmental Specifications
    • Operating Temperature: -20°C to +70°C (-4°F to 158°F)
    • Storage Temperature: -40°C to +85°C (-40°F to 185°F)
    • Relative Humidity: 10%–95% (non‑condensing)
    • Vibration Resistance: Compliant with IEC 60068‑2‑6 (2 g, 10–150 Hz)
    • Shock Resistance: Compliant with IEC 60068‑2‑27 (15 g, 11 ms duration)
    • EMI/RFI Immunity: Compliant with EN 61000‑6‑2 (industrial immunity) and EN 61000‑6‑4 (industrial emissions)
    • Altitude: Up to 2000 m (6562 ft) without derating
  3. Compliance & Compatibility
    • Compliance: CE marked; UL listed for industrial control equipment; IEC 61508 SIL 3 certified (when paired with T9451)
    • System Compatibility: AADvance controller systems; T9100 processor base units; T9300 3‑slot backplanes; T9451 digital output modules
    • Configuration Support: AADvance Engineering Tool (v4.0+) for diagnostic monitoring
    • Redundancy Support: Duplex (dual‑redundant) dual commoned configuration
    • Regulatory Approvals: RoHS compliant; compliant with ANSI/ISA 84.00.01 safety standards
  4. Performance Specifications
    • Channel Response Time: <1 ms (module signal to field output, dependent on T9451)
    • Fault Detection: Open/short circuit monitoring; power fault detection (via connected T9451 module)
    • Common Configuration: Dual commoned (common A and common B) for field wiring consolidation
    • Channel Isolation: 500 VDC between channels and channel‑to‑chassis for signal integrity and noise immunity
    • Redundancy Switchover Time: <100 ms (automatic, via paired T9451 module)

Functional Features

  1. 8 Duplex Isolated Channels: Provides channel‑to‑channel electrical isolation (500 VDC) and dual‑redundant paths to eliminate cross‑talk, prevent ground loops, and ensure failover in redundant applications.
  2. SIL 3 Compliance Support: Enables IEC 61508 SIL 3 certification when paired with T9451 digital output modules for safety‑critical control loops.
  3. Dual‑Redundant Power Buses: Delivers 24 VDC (18–32 VDC range) via two independent power buses for fault‑tolerant operation and seamless redundant switchover.
  4. Dual Commoned Field Wiring: Supports two separate common connections (common A and common B) to simplify field wiring and reduce installation time.
  5. Plug‑and‑Play Installation: Mounts quickly to T9300 backplanes without specialized tools for fast deployment and system integration.
  6. Front‑Panel Field Power Access: Dedicated connectors for field power inputs, accessible without removing the termination assembly or paired module.
  7. Diagnostic Integration: Works with T9451 modules to report open/short circuits and power faults via AADvance Engineering Tool for real‑time monitoring.
  8. IP20 Protection: Maintains dust and finger contact protection during operation and maintenance.
  9. EMI/RFI Immunity: Shields signals from electromagnetic interference for reliable data transmission in harsh industrial environments.
  10. RoHS Compliance: Meets environmental standards for hazardous substance restrictions.
  11. AADvance System Compatibility: Integrates seamlessly with T9300 backplanes and T9100 processors for end‑to‑end system functionality and redundant control.
  12. Dual Commoned Configuration: Reduces field wiring complexity by grouping channels into two common buses for final control elements.

Application Scenarios

  1. Oil & Gas Pipeline Solenoid Valve Control: Terminates wiring for 8 dual‑redundant solenoid valves in pipeline emergency shutdown (ESD) systems, using duplex isolation to eliminate ground loops and support SIL 3 safety loops for flow regulation.
  2. Chemical Plant Reactor Safety Shutdown: Interfaces wiring for motor starters controlling reactor feed pumps, centralizing 8 isolated redundant signals to simplify loop testing and maintenance in hazardous process areas.
  3. Power Generation Turbine Lube Oil Pump Control: Connects wiring to dual‑redundant lube oil pump motor starters, ensuring fast signal transfer and automatic failover for turbine protection systems with zero single‑point failure risk.
  4. Pharmaceutical Batch Process Solenoid Valve Control: Terminates wiring for solenoid valves in FDA‑compliant facilities, using isolated duplex channels to maintain signal accuracy and data integrity in validated processes.
  5. Marine Offshore FPSO Fire & Gas System: Consolidates wiring for 8 fire suppression system solenoid valves in harsh marine environments, with a rugged housing that withstands saltwater mist and vibration while isolating signals from electrical noise.
  6. Mining Conveyor Belt Emergency Stop Control: Interfaces wiring for dual‑redundant emergency stop relays, protecting modules from electrical noise and ensuring reliable safety monitoring in explosive and high‑vibration mining operations.

Additional Information

  • Origin: United States
  • Warranty: 12‑month warranty for new original units; extended support via Rockwell Automation service contracts
  • Compatibility: AADvance controller systems, T9300 backplanes, T9100 processors, T9451 digital output modules, AADvance Engineering Tool (v4.0+)
  • Installation: Plug into T9300 backplane; wire field devices to terminal blocks; configure diagnostics via AADvance Engineering Tool
  • Maintenance: Inspect terminal blocks quarterly for tightness; verify field power connections; clean housing to maintain IP20 protection
  • Accessories: Terminal block labels for channel identification; field power cable connectors (compatible with 2.5 mm² wire)
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ICS Triplex T9892 8‑Channel Duplex Digital Output Termination Assembly”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.