ICS Triplex T9084U AADvance IEC 61131 Workbench 5‑User USB License Key

Technical Specifications

  1. License & Software Specifications
    • License Model: 5‑user concurrent access; unlimited AADvance controller support
    • Software Compatibility: AADvance Workbench (Release 1.20.518 and later; Software Identity: 354130)
    • Programming Standards: IEC 61131‑3 (LD, FBD, ST, IL, SFC); IEC 61499 distributed function blocks
    • Safety Compliance: Supports IEC 61508 SIL 2/SIL 3 AADvance controller applications
    • Validation Method: Hardware‑bound USB key (no network license server required)
    • User Access: Concurrent logins for up to 5 engineers; role‑based permissions configurable via Workbench
  2. Hardware & Physical Specifications
    • Form Factor: USB 2.0 hardware key (plug‑and‑play)
    • Dimensions (H×W×D): 22 mm × 124 mm × 126 mm (0.87 in × 4.88 in × 4.96 in)
    • Weight: 0.1 kg (0.22 lb)
    • Enclosure: Rugged plastic casing (IP50 dust protection)
    • Interface: USB 2.0 (backward‑compatible with USB 1.1/3.0 ports)
    • Durability: 10,000+ insertion cycles; operating temperature range for key: 0°C to +60°C (32°F to 140°F)
Category:
Description
  1. Operating System Compatibility
    • Supported OS: Windows XP Service Pack 3 (32/64‑bit); Windows Vista (32/64‑bit); Windows 7 (32/64‑bit); Windows Server 2003 (32/64‑bit)
    • Driver Requirements: Native Windows USB HID driver (no additional software installation needed)
    • Network Independence: No network connection required for license validation (portable standalone operation)
  2. Controller & System Integration
    • Controller Compatibility: AADvance simplex, dual, triplicate controllers (all models)
    • I/O Support: Online I/O expansion; HART/line monitoring diagnostics for AADvance I/O modules
    • Protocol Support: Ethernet, Modbus RTU, Open Modbus TCP, OPC, AADvance native protocols
    • Diagnostics: Real‑time controller monitoring; I/O fault detection; safety loop validation
    • Commissioning: Online project download; controller parameter tuning; system backup/restore

Functional Features

  1. 5‑User Concurrent Access: Supports up to 5 engineers programming/configuring unlimited AADvance controllers simultaneously.
  2. Unlimited Controller Support: No restriction on the number of AADvance controllers managed per license.
  3. USB Hardware Key: Secure, portable license validation—no network license server required.
  4. IEC 61131‑3 Compliance: Full support for LD, FBD, ST, IL, SFC programming languages.
  5. IEC 61499 Support: Enables distributed function block development for modular industrial systems.
  6. SIL 2/SIL 3 Compatibility: Validates safety application development for IEC 61508 compliance.
  7. Windows Multi‑Version Support: Works with Windows XP SP3 to Windows 7 (32/64‑bit).
  8. Plug‑and‑Play Operation: Native USB HID driver; no additional software installation.
  9. Role‑Based Permissions: Configurable user access levels for project security.
  10. Online I/O Expansion: Supports AADvance I/O module scaling without system interruption.
  11. HART/Line Monitoring: Integrates with AADvance I/O diagnostics for field device health checks.
  12. Protocol Compatibility: Works with Ethernet, Modbus, OPC for enterprise integration.
  13. Real‑Time Monitoring: Tracks controller status, I/O faults, and safety loop performance.
  14. Project Management: Full IDE features for project creation, backup, and commissioning.
  15. Portable License: Rugged USB key for field deployment and multi‑workstation use.

Application Scenarios

  1. Oil & Gas ESD Engineering: 5‑user team programs triplicate AADvance controllers for emergency shutdown systems, using IEC 61131‑3 FBD/LD for safety logic and HART diagnostics for valve health monitoring.
  2. Chemical Plant Control Integration: Multi‑user team configures dual AADvance controllers for process interlocks, leveraging Modbus/OPC for DCS integration and unlimited controller support for plant‑wide scalability.
  3. Power Generation Burner Management: Engineers use ST/SFC to program AADvance controllers for burner safety, with SIL 3 compliance validated via the T9084U license and real‑time monitoring for flame detection systems.
  4. Pharmaceutical Batch Control: 5 concurrent users develop IEC 61499 distributed function blocks for AADvance controllers, ensuring FDA compliance with audit trails and role‑based access control.
  5. Marine Offshore Fire & Gas: Portable USB key enables field programming of AADvance controllers for fire suppression systems, with Windows 7 compatibility for on‑vessel workstations.
  6. Mining Process Automation: Team uses the license to configure simplex AADvance controllers for conveyor control, with online I/O expansion for adding sensor modules without downtime.

Additional Information

  • Origin: United States
  • Warranty: 12‑month warranty for new original USB keys; extended support via Rockwell Automation service contracts
  • Compatibility: AADvance Workbench (Release 1.20.518+), AADvance controllers (simplex/dual/triplicate), Windows XP SP3–Windows 7 (32/64‑bit)
  • Installation: Plug USB key into workstation; launch AADvance Workbench for automatic license validation
  • Maintenance: Firmware updates via AADvance Workbench; key replacement via Rockwell Automation licensing services
  • Accessories: USB key protective case, AADvance Workbench installation media, user documentation
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ICS Triplex T9084U AADvance IEC 61131 Workbench 5‑User USB License Key”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.