GE IS220PPRFH1B

Product Introduction

The IS220PPRFH1B is a PROFIBUS Master Gateway I/O Module developed by General Electric as part of the Mark VIe Speedtronic Control Series, acting as a critical communication bridge between Mark VIe controllers and PROFIBUS DP field devices. It functions as a PROFIBUS DPV0 and Class 1 master, mapping I/O data from PROFIBUS slaves to the Mark VIe I/O Ethernet for seamless integration into turbine control and industrial automation systems. The module features a Hilscher COM‑C PROFIBUS communication module with an RS‑485 interface, dual redundant Ethernet ports, and a 32‑bit embedded processor optimized for real‑time data transfer.
Category:
Description

Technical Specifications

  • Manufacturer: General Electric (GE) Energy, GE Boards & Turbine Control
  • Product Series: Mark VIe Speedtronic Control System
  • Module Type: PROFIBUS Master Gateway I/O Module (PPRF)
  • Part Number: IS220PPRFH1B (Functional Revision B)
  • PCB Coating: Conformal coating for environmental protection against dust, moisture, and corrosion
  • Processor: 32‑bit embedded local processor optimized for gateway data processing
  • Communication Chip: Hilscher COM‑C PROFIBUS communication module
  • Memory: 8 MB flash memory for program storage, 4 MB DRAM for data buffering
  • Power Supply: 28 V DC (nominal), voltage range 27.4–28.6 V DC; typical current draw 150 mA DC
  • PROFIBUS Interface: RS‑485 via DE‑9 D‑sub connector; PROFIBUS DP V0/V1 compliant
  • PROFIBUS Performance: Up to 125 slave devices; 244 bytes input/244 bytes output data capacity; baud rate 9.6 kbps–12 Mbps
  • Ethernet Interfaces: 2 × 100Base‑TX Ethernet ports (RJ‑45) for redundant I/O Ethernet connection
  • Terminal Board Compatibility: IS200SPIDG1A terminal board for field wiring integration
  • Operating Temperature: -40°C to +70°C
  • Storage Temperature: -55°C to +85°C
  • Humidity Range: 5%–95% non‑condensing
  • Vibration Resistance: Compliant with IEC 60068‑2‑6 (10–500 Hz, 10 g peak)
  • Shock Resistance: Compliant with IEC 60068‑2‑27 (50 g, 11 ms duration)
  • Isolation: Channel‑to‑backplane isolation (2500 Vrms) for noise immunity
  • Certifications: UL/cUL Class I, Div 2 compliant; IEC 61010‑1 safety certified; CE marked for EMC compliance
  • Dimensions: 82.6 mm × 41.9 mm × 121 mm (3.25 in × 1.65 in × 4.76 in)
  • Weight: 0.5 kg (1.1 lbs)

Functional Features

  • PROFIBUS Master Capability: Acts as PROFIBUS DPV0 and Class 1 master, enabling data exchange with up to 125 PROFIBUS DP slave devices.
  • Mark VIe Integration: Maps PROFIBUS slave I/O data to Mark VIe I/O Ethernet, ensuring seamless communication with central controllers.
  • Redundant Communication: Dual 100Base‑TX Ethernet ports support redundant data transfer; hot‑backup mode with two PPRF modules for uninterrupted operation.
  • High‑Speed Data Transfer: PROFIBUS baud rate up to 12 Mbps and 244 bytes input/output capacity enable fast real‑time data processing.
  • Conformal Coating: Protects against dust, moisture, and corrosion for reliable performance in harsh industrial environments.
  • Terminal Board Flexibility: Works with IS200SPIDG1A terminal board for easy field wiring and integration.
  • Diagnostic Monitoring: Built‑in diagnostics for PROFIBUS communication errors, slave device status, and Ethernet link health, with status LEDs for rapid fault detection.
  • ToolboxST Compatibility: Fully integrated with GE ToolboxST for configuration, real‑time monitoring, and firmware updates.
  • Hot‑Swappable Design: Supports hot‑swap replacement without system shutdown, reducing maintenance downtime.

Application Scenarios

  • Mark VIe Turbine Control: Gateway module in Mark VIe systems for gas/steam turbines, connecting controllers to PROFIBUS‑based sensors, actuators, and valves.
  • Power Generation: Deployed in power plants to integrate PROFIBUS devices (e.g., generator protection relays, circuit breakers) into Mark VIe control systems.
  • Oil & Gas Infrastructure: Used in compressor stations, LNG plants, and offshore platforms to connect PROFIBUS field devices with Mark VIe safety and control systems.
  • Industrial Automation: Bridges Mark VIe controllers with PROFIBUS networks in manufacturing lines for conveyor control, pump monitoring, and safety interlocks.
  • Redundant Control Architectures: Critical component in hot‑backup and TMR systems for high‑reliability applications requiring fault tolerance.
  • Retrofit Projects: Compatible with legacy Mark VI systems for upgrade to Mark VIe, enabling integration of existing PROFIBUS devices into modern control architectures.

Compatibility

  • GE Platforms: Mark VIe Speedtronic control systems, compatible with simplex and redundant architectures.
  • Terminal Boards: IS200SPIDG1A for field wiring connection.
  • PROFIBUS Devices: PROFIBUS DPV0/V1 slave devices (sensors, actuators, drives, and I/O modules).
  • Communication Protocols: 100Base‑TX Ethernet (Mark VIe I/O Ethernet), PROFIBUS DP V0/V1 (RS‑485).
  • Power Supplies: 28 V DC industrial power systems with 27.4–28.6 V DC range.
  • Software: GE ToolboxST for configuration, diagnostics, and firmware updates.

Installation Notes

  1. Backplane Mounting: Install in Mark VIe standard chassis, align with backplane connectors, and secure with locking clips to prevent vibration‑induced disconnections.
  2. Power Connection: Supply 28 V DC to power terminals, verify correct polarity to avoid component damage; ensure power supply meets 27.4–28.6 V DC range.
  3. PROFIBUS Wiring: Use shielded twisted‑pair cables for RS‑485 connection; terminate bus ends with 150 Ω resistors to prevent signal reflection.
  4. Ethernet Configuration: Connect dual Ethernet ports to Mark VIe I/O Ethernet network; assign unique IP addresses and enable redundancy mode for high availability.
  5. Terminal Board Setup: Mount IS200SPIDG1A terminal board and connect field devices to corresponding terminals; verify wiring against module pinout specifications.
  6. Configuration: Use ToolboxST to set PROFIBUS parameters (baud rate, slave addresses, data mapping) and Ethernet communication settings.
  7. Diagnostic Check: After installation, perform self‑test via ToolboxST to verify PROFIBUS communication, Ethernet links, and module functionality.
  8. Environmental Protection: Ensure installation enclosure has IP54 or higher rating to complement conformal coating and protect against dust, moisture, and chemical exposure.
  9. Post‑Installation Testing: Conduct PROFIBUS slave device scan, data exchange test, and redundancy failover simulation to confirm module operation before system commissioning.

Key Advantages

  • PROFIBUS Integration: Enables seamless communication between Mark VIe controllers and PROFIBUS DP field devices, expanding system compatibility.
  • Redundant Communication: Dual Ethernet ports and hot‑backup mode ensure high availability and uninterrupted operation in critical applications.
  • High‑Speed Data Transfer: PROFIBUS baud rate up to 12 Mbps and large data capacity support fast real‑time control and monitoring.
  • Rugged Design: Conformal coating and wide operating temperature range ensure reliable performance in harsh industrial environments.
  • Advanced Diagnostics: Built‑in diagnostics and status LEDs enable rapid fault detection and troubleshooting, reducing maintenance time and costs.
  • ToolboxST Compatibility: Simplifies configuration, monitoring, and firmware updates, lowering total cost of ownership.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE IS220PPRFH1B”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.