GE IS210AEBIH3BEC

Product Introduction

The IS210AEBIH3BEC is a high – performance AE Bridge Interface Card engineered by General Electric for the Speedtronic Mark VIe Wind Series turbine control systems. It serves as a pivotal communication and signal – routing bridge, enabling seamless real – time data exchange between on – tower AE (Automation Equipment) modules and the central Mark VIe controller, which is essential for precise turbine control and monitoring. This card is a functional enhanced variant of the IS210AEBIH series, boasting improved communication stability, expanded I/O capacity, and advanced diagnostic features, all while maintaining compatibility with existing Mark VIe infrastructure.
Category:
Description

Technical Specifications

  • Manufacturer: General Electric (GE) Energy
  • Product Series: Mark VIe Wind Series
  • Board Type: Advanced AE Bridge Interface Card (AEBI)
  • Functional Variant: 3BEC (enhanced I/O and diagnostics vs. base AEBI models)
  • PCB Coating: Conformal coating for environmental resilience
  • Dimensions: 292 mm × 130 mm × 27 mm (29.2×13×2.7 cm)
  • Weight: 0.32 kg
  • Operating Temperature: -40°C to +70°C
  • Storage Temperature: -55°C to +85°C
  • Humidity Range: 5% – 95% non – condensing
  • Vibration Resistance: Compliant with IEC 60068 – 2 – 6 (10–500 Hz, 10 g peak)
  • Shock Resistance: Compliant with IEC 60068 – 2 – 27 (50 g, 11 ms duration)
  • Power Requirements: 24 VDC (logic power); 5 VDC (communication circuits); typical power consumption 10 W
  • Communication Interfaces: 2 × Ethernet (10/100 Mbps, redundant) for controller connection; 4 × RS – 485 (Modbus RTU) for AE module communication; 1 × CAN bus for internal data transfer
  • I/O Interfaces: 12 × digital input (24 VDC, sinking/sourcing); 10 × digital output (relay, 3 A/250 VAC); 6 × analog input (4 – 20 mA, isolated) for sensor status monitoring
  • Connectors: 1 × main right – angle connector; 8 × vertical pin connectors for AE module interface; 4 × configuration jumpers
  • Mounting: DIN – rail compatible with 8 screw – mounting points for chassis or enclosure installation
  • Certifications: UL/cUL Class I, Div 2 compliant for hazardous locations; IEC 61010 – 1 safety certified; CE marked for EMC compliance
  • EMC Protection: Integrated surge arrestors and EMC filters for communication and I/O lines to resist lightning – induced transients

Functional Features

  • High – Speed Bridge Communication: Enables low – latency data transmission between on – tower AE modules (sensors, actuators) and the Mark VIe controller, supporting real – time pitch control, yaw alignment, and brake operation.
  • Enhanced I/O Capacity: 12 digital inputs, 10 digital outputs, and 6 analog inputs expand the range of connected devices, reducing the need for additional interface modules.
  • Advanced Diagnostic Suite: Monitors communication link health, power supply voltages, I/O channel integrity, and internal component temperatures, generating detailed fault codes for remote troubleshooting and proactive maintenance.
  • Dual – Redundant Communication: Two Ethernet ports support redundant Mark VIe controller setups, enabling automatic failover to ensure continuous turbine operation during single – point communication failures.
  • Rugged Environmental Design: Conformal coating protects against salt spray, moisture, and dust, extending operational life in offshore and coastal wind farm deployments.
  • Plug – and – Play Integration: Pre – configured for Mark VIe Wind Series, allowing rapid replacement and system integration without complex programming or reconfiguration.
  • Channel – to – Channel Isolation: Digital and analog I/O channels feature full isolation to eliminate ground loops and cross – talk, improving signal accuracy and system stability.
  • Surge & ESD Protection: Built – in surge protectors and electrostatic discharge (ESD) safeguards shield the card against voltage transients common in wind turbine environments.

Application Scenarios

  • Mark VIe Wind Turbine Control: Core component in Mark VIe Wind Series systems, facilitating communication between on – tower AE modules and the central controller for precise pitch, yaw, and brake control.
  • Top – of – Tower (ToT) Enclosures: Installed in the turbine’s top – box enclosure to interface with on – tower sensors (anemometers, vibration monitors) and actuators (pitch motors, yaw drives), simplifying wiring and reducing signal loss.
  • Offshore Wind Farm Deployments: Ideal for offshore wind turbines, as its conformal coating and rugged design resist salt spray, high humidity, and extreme temperature fluctuations.
  • Redundant Control Systems: Deployed in wind turbines requiring high availability, such as those in critical power grids or remote locations, supporting seamless failover between redundant controllers.
  • Wind Farm Retrofit Projects: Compatible with older GE wind turbine models for upgrade to Mark VIe control systems, extending the operational lifespan of existing wind farm assets.
  • Utility – Scale Wind Operations: Used in large – scale onshore wind farms to ensure reliable data transmission, enabling centralized monitoring and control via the Mark VIe controller network.

Compatibility

  • GE Platforms: Mark VIe Wind Series turbine control systems.
  • Controller Configurations: Redundant and simplex Mark VIe controllers with Ethernet/IP communication capability.
  • AE Modules: GE on – tower automation equipment, including sensor hubs, actuator controllers, and condition – monitoring units.
  • Communication Protocols: Ethernet/IP, Modbus RTU (RS – 485), and CAN bus for internal system communication.
  • Power Supplies: 24 VDC wind turbine auxiliary power systems, with tolerance for ±10% voltage fluctuations.
  • Software: Fully compatible with GE ToolboxST for configuration, real – time monitoring, and firmware updates.

Installation Notes

  1. Mounting: Secure the card on a DIN rail or chassis using 8 screws in the top – box enclosure, ensuring at least 50 mm of clearance for wiring and ventilation.
  2. Wiring: Connect AE modules to vertical pin connectors using shielded twisted – pair cables; separate power and communication lines to minimize electromagnetic interference.
  3. Power Connection: Supply 24 VDC to logic power terminals and 5 VDC to communication circuits, verifying correct polarity to prevent component damage.
  4. Communication Setup: Use ToolboxST to configure Ethernet and RS – 485 parameters to match the Mark VIe controller and AE module settings.
  5. Redundancy Configuration: In redundant systems, connect the card to both primary and secondary controllers to enable automatic failover during communication or controller faults.
  6. Environmental Sealing: Ensure the top – box enclosure has an IP54 or higher rating to complement the card’s conformal coating and prevent moisture ingress.
  7. Post – Installation Testing: Run a full diagnostic check via ToolboxST to validate I/O functionality, communication links, and fault – detection capabilities before turbine operation.

Key Advantages

  • Enhanced Data Throughput: Supports high – speed communication and expanded I/O, meeting the demands of complex wind turbine control systems.
  • Harsh Environment Resilience: Conformal coating and wide temperature range enable reliable operation in offshore and extreme onshore conditions.
  • Proactive Maintenance Support: Advanced diagnostics reduce unplanned downtime by enabling early fault detection and remote troubleshooting.
  • Redundancy for High Availability: Dual Ethernet ports support redundant controller setups, maximizing turbine uptime and energy output.
  • Cost – Effective Integration: Plug – and – play design and compatibility with existing Mark VIe systems lower installation and upgrade costs.
  • Improved Signal Integrity: Channel isolation eliminates ground loops and cross – talk, ensuring accurate sensor data and reliable actuator control.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE IS210AEBIH3BEC”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.