GE F650BFBF2G0HIE Digital Feeder Protection Relay

Technical Specifications

  • Manufacturer: General Electric (GE)
  • Series: Multilin F650
  • Rated Voltage: 120/240V AC/DC (configurable)
  • Rated Current: 1A or 5A (configurable)
  • Protection Functions:
    • Phase overcurrent (50/51)
    • Ground fault (50N/51N, 67N)
    • Negative sequence overcurrent (46)
    • Overvoltage/undervoltage (59/27)
    • Frequency protection (81O/U)
    • Power direction (67)
    • Thermal overload
Category:
Description
  • Measurement Accuracy:
    • Current/voltage: ±0.2%
    • Power: ±0.5%
    • Energy: ±0.5%
  • Communication Interfaces:
    • Dual fiber-optic Ethernet ports (supporting IEC 61850-9-2 LE, GOOSE)
    • RS-485 (Modbus, DNP3)
  • Data Logging:
    • Event records: >128,000 with timestamps
    • Fault recording: >100 events, up to 60 seconds per event
  • Clock Synchronization: IRIG-B, SNTP, PTP (IEEE 1588)
  • Operating Temperature: -20°C to +70°C (industrial grade)
  • Storage Temperature: -40°C to +85°C
  • Relative Humidity: 5% to 95% RH (non-condensing)
  • Power Requirements: Dual redundant power inputs (125V DC/AC or 250V DC/AC)
  • Power Consumption: Typical <25W
  • LED Indicators: 10 programmable LEDs for status, alarms, and trip signals
  • Diagnostic Functions: Power-on self-test, runtime hardware/software monitoring, communication status, I/O status diagnosis, and self-test reports.

Functional Characteristics

  • Multifunction Integration: Combines protection, control, measurement, metering, and monitoring functions, reducing the need for multiple devices and simplifying wiring.
  • High-Precision Measurement: Built-in high-precision measurement unit replaces standalone energy meters and measurement devices, providing IEC 62053-compliant Class 5 energy quality monitoring.
  • IEC 61850 Support: Enables high-speed transmission of sampled values (SV) and Generic Object-Oriented Substation Event (GOOSE) messages via fiber-optic Ethernet, facilitating rapid and reliable communication between devices.
  • Advanced Event Logging and Fault Recording: Provides critical data for root cause analysis of power system incidents, supporting up to 128,000 event records and over 100 fault recordings.
  • Robust Design: Industrial-grade design with high electromagnetic interference immunity (IEC 60255 compliant), ensuring stable operation in harsh electrical environments.
  • Dual Redundancy: Dual power inputs and dual Ethernet ports provide high availability, ensuring continued operation during single-point failures in power or communication.
  • User-Friendly Interface: Configurable via front panel, local PC software (SigmaNet), or remote SCADA system, with intuitive operation and navigation.

Application Scenarios

  • Industrial Facilities: Protects main incoming lines, bus ties, feeder circuits, large motors, transformers, and capacitor banks in factories, ensuring production continuity and equipment safety.
  • Commercial Buildings and Data Centers: Safeguards critical power distribution circuits, ensuring reliable and stable power supply.
  • Public Utilities: Core equipment in urban distribution networks and substation automation systems (SAS), supporting feeder automation (FA) and fault location, isolation, and service restoration (FLISR) functions.
  • Renewable Energy Projects: Used in wind farms and photovoltaic power plants for protection of collector lines, step-up substations, and grid connection points, meeting strict grid interconnection requirements.
  • Special Applications: Suitable for railway traction power systems, shipboard power systems, and oil and gas platforms, among others.
  • Smart Substations: Ideal for new smart substation projects or digital upgrades of traditional substations, enabling intelligent and automated grid operations.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE F650BFBF2G0HIE Digital Feeder Protection Relay”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.